Seba KMT KMK 8 Communications network cable tester

Code: Seba-KMT KMK-8 KMK8


 

Datasheet PDF, 0.69 Mb
   

Description

KMK 8

The KMK 8 calculates from the pre- programmed or the user specific entered cable parameters and the entered or measured cable temperature the cable lengths as well as the distance to the fault.

Key benefits:

  • Integrated Reflectometer (TDR)
  • Active bridge for high precision R and C measurements and DC and AC fault location
  • Measurement by Graaf method in connection with an active slave at the far end
  • Passive Wheatstone bridge for R and C measurements and DC and AC fault location
  • Test Systems for Pre-measurement, Quick test and Quality testing
  • Measurement of interference voltages
  • Warning and information system
  • Remote control for the operation of the electronic far end loop control switch
 

Standard accessories

 

 

Recommended options

Optional accessories

- KMK 80S slave unit to perform synchronous

end to end Graaf measurements

- KMK 8 - Calibration Certifi cate

- KTS 8 - PT 1000 Temperature sensor

 

More products SEBAKMT

SEBA SFX 5-1000 SPG 5-1000 CABLE FAULT LOCATION SYSTEM ON LOW AND MEDIUM VOLTAGE CABLES

• ICEplus for the easy and reliable fault prelocation without interference from branches
• High surge energy for pinpointing
• Compact and lightweight construction
• Testing up to 5 kV
• Automatic detection of the breakdown voltage
• Pinpointing with the integrated surge generator 0 … 2 / 4 kV 1000 J
• Pulsed DC for sheath fault pinpointing

 

SEBA KMT VIVAX METROTECH VLOC2 LINE LOCATION AND TRACER FOR UNDERGROUND PIPES AND CABLES

• Carbon-reinforced plastic housing
• Protection class IP 54 for use in any weather conditions
• Colour display
• High-speed processor
• Several location modes with orientation using a compass
• A large number of available frequencies
• Depth/amperage at the press of a button or sustained

 

SEBA KMT PIL 8 PHASENLUX PHASE IDENTI?CATION IN EARTHED AND SHORT-CIRCUITED MEDIUM VOLTAGE CABLES

• Maintenance free transceiver clamps
• Suitable for any type of switch gear
• Requires only one person
• Easiest operation
• Absolute safe phase identification


SEBA KMT HV TESTER 25KV HIGH VOLTAGE DC TESTER

• DC output voltage of 0 - 25 kV
• Portable HV Tester
• DC and insulation testing of cables, joints, electrical fixtures, etc.
• High flexibility with built-in battery

 

SEBA KMT SEBALOG N-3 AUTOMATIC WATER LEAK LOCATION WITH CORRELATING NOISE LOGGER NETWORK

• Latest measured data available every day
• Correlation function
• No time-consuming driving past individual loggers
• Remote configuration
• Very simple installation process
• Cost-effective data transmission

 

SEBA DIGIPHONE+ ESG NT PINPOINTING ACOUSTIC PINPOINTING SET FOR STEATH FAULT LOCATION IN UNDERGROUND CABLES

• Perfect acoustic quality and noise immunity
• Automatic filtration of interfering signals
• Automatic zero calibration, no adjustments necessary
• History mode
• Acoustic and step voltage fault location in one device
• BNR technology for perfect acoustic quality and noise immunity
• Automatic filtration of interfering signals
• Automatic setting of all parameters, no adjustments necessary

 

SEBA KMT T26/1 T26/1A T26/1B T26/1C HIGH VOLTAGE CABLE TESTING

• DC voltages of up to 400 kV and 650 kV
• Great mobility
• Simple, safe operation
• Thermal overload shutdown
• Discharge switch

 

SEBA KMT SEBALOG CORR MULTI-CORRELATOR LOGGER FOR WATER LEAK DETECTION AND LOCATION

• Correlation with up to 8 sensors at the same time
• GPS navigation directly to the leak
• Radio communication to the sensors
• No staff needed for night measurement
• Sound velocity assistant (V-assistant)
• Unique pinpointing mode

 

SEBA KMT HPA35 HPA50 HPA58 HPA78 AC HIGH VOLTAGE HIPOT TESTING WITHSTANDING

• HPA 35, AC testing up to 35 kVrms
• HPA 50 / 58 AC testing up to 50 / 58 kVrms
• HPA 78, AC testing up to 78 kVrms

 

SEBA SWG 505 SURGE WAVE GENERATOR FOR FAULT LOCATION IN CABLES SWG505

• Voltage Ranges : 0.. 3kV / 4kV / 5kV
• Energy : 180J / 320J / 500J
• MAx Current Imax : 129mA / 182mA / 213mA
• Optimized surge energy for switchable capacitors
• ICE - Impulse Current Method
• ARM - Arc Reflection Method