Seba KMT EZ-Thump Cable Fault Location System on LV/MV Cables

Code: Seba-KMT EZ-Thump


 

Datasheet PDF, 0.94 Mb
   

Description

EZ-Thump

The practical and efficient solution for the fast on spot fault location. 

The EZ-Thump is the compact and light weight, battery or mains powered solution for the fault location in MV or LV cables. It presents the ideal supplement for a satellite-based concept in areas of lower distribution density and failure rate, where fast reaction, weight, size and economy are the driving factors. The system requires no adjustments and need only to be operated by a rotary encoder. 

Key benefits:

  • Easiest, fully automatic operation
  • All in one small and portable unit
  • ARM Prelocation
  • Pinpointing with 500 J
  • Available as 4 or 12 kV version
  • Bright, brilliant colour display
  • Battery operation

 

 

 

                        Very easy to operate

                        No user settings required

                        Easy and Expert Mode

                        Direct display of all important data

                        Small and portable

                        Sturdy and weatherproof for outdoor use

                        USB upload/download interface

                        Can be carried in any car

                        Battery operation

 

Applications

                        Fault location in low voltage networks

                        Fault location in medium voltage networks

                        Fault location for street lighting

                        Sheath fault pinpointing

                        DC low voltage testing (4 kV version)

                        DC medium voltage testing (12 kV version)

 

 

Standard accessories

  • EZ-Thump fault location system, 5.7" color LCD 4 kV
  • EZ-Thump fault location system, 5.7" color LCD 12 kV

 

 

Recommended options

Sectionalizing option (auto transformer and joint detection

 

More products SEBAKMT

SEBA DIGIFLEX COM REFLECTOMETER FAULT LOCATING ON METALLIC TELECOMM LINES, COAXIAL AND POWER CABLES

• Measuring range from 5 m up to 30 km
• Line comparison with 2 measuring inputs
• High resolution in the near and far range
• Weatherproof case
• Solid housing for rugged fi eld use

 

SEBA FAULT SNIFFER FOR DETECTION OF BURNING GASES FROM FAULT CABLES UNDERGROUND

• Customers can stay connected
• Fault location with no supply interrupt
• Reliable avoidance of incorrect excavations
• Fast and easy location of faults
• Can be used on straight or branched networks
• Handy size, easy to transport
• No pre-location required
• Accuracy in the decimetre range
• Sensitive to several specifi c gases and therefore suitable for any insulation material

 

SEBA KMT OWTS M28 PARTIAL DISCHARGE TEST AND FAULT LOCATION SYSTEM IN CABLE INSULATION

• PD Measurement by means of DAC similar to nominal net frequency
• Online processing for complex PD-Diagnosis
• Portable test system, compact design and low weight
• Integrated tan d - measurement

 

SEBA KMT VFL CR-28..60 VLF TEST SYSTEMS FOR MEDIUM VOLTAGE CABLE TESTING

• VLF CR-28 up to cable series 15 kV
• VLF CR-40 up to cable series 23 kV
• VLF CR-60 up to cable series 35 kV
• VLF, DC and sheath fault testing in one device
• Portable thanks to two-part construction
• High test capacitance
• Integrated discharge system
• Reporting

 

SEBA SURGEFLEX SFX-15 SFX-25 CABLE FAULT LOCATING SYSTEM

• » DC-Testing up to 15 kV / 25 kV (depending on model)
• » Prelocating
• » - Reflection measurement
• » - ARM-Measurement (Arc reflection method)
• » - ICE Impulse current method
• » Cable tracing (optional)
• » Pin-pointing
• » - Distance and acoustic measurement
• » - Audio frequency methods (optional)
• » Battery and mains operation

 

SEBA KMT HPG 50..80-D DC & AC HIGH VOLTAGE CABLE TESTER

• HPG 50-D, AC testing up to 35 kVRMS/ DC testing up to 100 kV
• HPG 70 / 80-D, AC testing up to 50 / 58 kVRMS / DC testing up to 140 / 150 kV
• Suitable for AC testing and DC testing
• Compact, cast-resin high-voltage transformers
• Separate control and HV-units
• Voltage continuously adjustable
• Powerful system: 1,2 kVA continuous operation, up to 3 kVA 60 min. short-time operation

 

SEBA KMT VCAM LSR SEWER PIPELINE VIDEO INSPECTION CAMERA

• Flexibility, allowing multiple uses
• 3 camera head options
• Recording of the video via the VIDEO OUT
• Integrated distance counter and 640 Hz sonde
• Integrated rechargeables
• Expandable, with flex rod incorporating 9 or 11 mm diameter camera head

 

SEBA KMT HVB-10 10KV CABLE FAULT LOCATION, STEATH TESTING AND PINPOINTING MEGGER HVB10

• Output voltage 0 … 10 kV DC, bi-polar
• Automatic test sequence
• Bi-polar prelocation for the elimination of external influences
• Detection and indication of wrong connections
• Touchscreen and rotary encoder
• Only one HV connection cable
• Completely independent of the parameters of auxiliary lines

 

SEBA KMT CDS CABLE DIAGNOSTIC SYSTEM FOR THREE PHASE IRC AND RVM DIAGNOSTICS

• Absolutely non-destructive condition evaluation of PE / XLPE / paper-oil insulated cable systems
• Simple operation and automatic measurement procedures
• Three-phase parallel measurement for current and voltage - duration of a complete measurement 1 hour
• Extended dynamic range for IRC measurement for long cable segments
• Measurement of charging current during formation

 

SEBA KMT MFM 10 CABLE STEATH FAULT LOCATION SYSTEM

• Testing, prelocation and pinpointing of sheath faults
• Voltage up to ±10 kV DC
• High current of up to 750 mA
• Only one HV connection cable
• Automatic measurement and protocolling