Megger TORKEL 820 BS-49092 Telecom Battery Load Discharge Tester Programma

Code: Megger TORKEL 820 BS-49092 TLX830 TLX850 Programma


 

Datasheet PDF, 0.49 Mb
           

Description

• Combines efficiency with portability

• Batteries can be tested "in service"

• Discharge 24 and 48 V batteries at a current of 270 A 
• 12 V batteries at 135 A
• Two or more TORKEL 820 units and/or extra load units TXL, can be linked together if you need higher current. 
• Discharging proceeds at constant current, constant power or constant resistance, or in accordance with a pre-selected load profile.

Batteries can be tested "in service"

 

??Unit adjusts to include load currents in the test parameters

??User adjustable alarm and shutdown points to avoid excessive discharge

??View test parameters/results "real time" as testing progresses using TORKEL WIN

software

??Easily save results to a PC for analysis, report generation and storage

 

 

 

During a power outage, crucial telecommunication and radio equipment must be kept operating by batteries. Unfortunately, however, the capacity of such batteries can drop significantly for a number of reasons before their calculated life expectancy is reached. Battery capacity should thus be checked to prevent expensive downtime in the event of a power failure.

 

Standard accessories

TORKEL 820

Complete with:

  • Cable set GA-00554
  • Transport case GD-00054 BS-49092
 

Recommended options

Optional

TORKEL Win PC software BS-8208X

Extra loads

TXL830 BS-59093

TXL850 BS-59095

 

Cable sets

Cable set for TXL830 and TXL850 2 x 3 m, 70 mm2, with cable lug. Max 100 V 270 A. Weight: 5.0 kg (11 lbs) GA-00554

Sensing lead set

Cable set for measuring voltage at battery terminals. 2 x 5 m (16.4 ft) GA-00210

Clamp-on ammeters

DC clamp-on ammeter, 200 A To measure current in circuit outside TORKEL XA-12992

DC clamp-on ammeter, 1000 A To measure current in circuit outside TORKEL XA-12990

 

BVM

Including:

Dolphin clips, Power & signal connector, Power supply, Connection cables and Carrying case

BVM150 With TORKEL Win software System of 16 BVM units CJ-59092

BVM300 With TORKEL Win software System of 31 BVM units CJ-59093

BVM600 With TORKEL Win software System of 61 BVM units CJ-59096

BVM150 With PowerDB software System of 16 BVM units CJ-59192

BVM300 With PowerDB software System of 31 BVM units CJ-59193

BVM600 With PowerDB software System of 61 BVM units CJ-59196

 

More products MEGGER

MEGGER MIT2500 2.5KV INSULATION TESTER

• Insulation testing up to 2.5 kV and 200 GΩ range in a handheld instrument
• Guard terminal for high resistance accuracy
• Adjustable insulation test voltage from 50 V to 2500 V
• Stabilised insulation test voltage

 

UNIVERSAL CIRCUIT BREAKER TEST SETS MEGGER DDA-3000 AND DDA-6000

• Model DDA-1 Digital Data Acquisition Instrumentation and Control System
• High-current output: 60,000 A for Model DDA-6000; 35,000 A for Model DDA-3000
• Digital signal processing (DSP) technology
• Variable pulse time and firing angle output current control
• Compliant with NEMA AB-4 test guidelines

 

SMART PRIMARY INJECTION TEST SYSTEM MEGGER SPI225

• Up to 2000A output
• Smallest primary injection test system in its class
• First unit on the market to eliminate variac control
• Output current regulation
• Designed for switchgear commissioning, circuit breaker, CT commissioning, ground grid and relay testing
• Software includes thousands of circuit breaker TCC curves

 

MICROPROCESSOR-BASED CIRCUIT BREAKER TEST SETS MEGGER PS-9116

• Portable, three piece chassis
• Tests wide range of air-frame breakers
• Test result printout capability

 

MEGGER MIT515/2 5KV INSULATION RESISTANCE MEGOHMMETER

• RE>Act mode enhanced accuracy and safety
• PI predictor function (PIp)
• Measures up to 20 TΩ
• Up to 3 mA noise rejection

 

MEGGER DET14C 1000-761 DET24C 1000-762 EARTH RESISTANCE CLAMP METER

• Elliptical clamp shape improves access to earth cables and straps up to 50 mm
• Low maintenance flat jaw interface
• Measures ground resistance from 0.05 O to 1500 O
• Measures true RMS ground leakage current from 0.5 mA rms to 35 A rms
• CAT IV 600 V safety rating
• Backlit LCD display

 

MEGGER TTR300 TTR310 TTR330 THREE-PHASE TRANSFORMER TURNS RATIO METER

• Stand-alone or remote-control operation
• Accurately measures ratio, phase deviation and excitation current
• Field upgradeable without compromise to calibration
• Built-in capability for storing and downloading test results in an XML format, via RS-232, Ethernet or USB ports (depending on model)
• Works in the presence of high interference/high voltage
• Highest ratio measurement (45,000:1); highest accuracy (0.1%)
• Displays % error vs. name plate with pass/fail limits

 

MEGGER OTS60AF OTS80AF OTS100AF OIL BREAKDOWN TESTER 60KV 80KV 100KV

• Test voltages : 60 kV, 80 kV and 100 kV
• Laboratory instruments for measuring insulating oil breakdown voltage
• Lock in precision - oil vessel with lockable adjustment
• Bright 3.5" colour display
• Suitable for mineral, ester and silicon oils
• Trip detection circuit with direct measurement of voltage and current
• Ultra fast (< 10 µs) HV switch off time

 

MICRO-OHMMETER MEGGER MOM600A

• Compact and tough
• Straight forward to use
• 600 A output current

 

MEGGER FRAX FRAX-99 FRAX-101 FRAX-150 FREQUENCY RESPONSE ANALYZER

• Frequency range 0.1 Hz - 25 MHz, user selectable
• Highest dynamic range and accuracy in the industry
• Smallest and most rugged FRA?instrument in the industry
• Fulfills all international standards for SFRA measurements
• Advanced analysis and decision support built into the software
• Imports data from other FRA test sets