Megger TORKEL 820 BS-49092 Telecom Battery Load Discharge Tester Programma

Code: Megger TORKEL 820 BS-49092 TLX830 TLX850 Programma


 

Datasheet PDF, 0.49 Mb
           

Description

• Combines efficiency with portability

• Batteries can be tested "in service"

• Discharge 24 and 48 V batteries at a current of 270 A 
• 12 V batteries at 135 A
• Two or more TORKEL 820 units and/or extra load units TXL, can be linked together if you need higher current. 
• Discharging proceeds at constant current, constant power or constant resistance, or in accordance with a pre-selected load profile.

Batteries can be tested "in service"

 

??Unit adjusts to include load currents in the test parameters

??User adjustable alarm and shutdown points to avoid excessive discharge

??View test parameters/results "real time" as testing progresses using TORKEL WIN

software

??Easily save results to a PC for analysis, report generation and storage

 

 

 

During a power outage, crucial telecommunication and radio equipment must be kept operating by batteries. Unfortunately, however, the capacity of such batteries can drop significantly for a number of reasons before their calculated life expectancy is reached. Battery capacity should thus be checked to prevent expensive downtime in the event of a power failure.

 

Standard accessories

TORKEL 820

Complete with:

  • Cable set GA-00554
  • Transport case GD-00054 BS-49092
 

Recommended options

Optional

TORKEL Win PC software BS-8208X

Extra loads

TXL830 BS-59093

TXL850 BS-59095

 

Cable sets

Cable set for TXL830 and TXL850 2 x 3 m, 70 mm2, with cable lug. Max 100 V 270 A. Weight: 5.0 kg (11 lbs) GA-00554

Sensing lead set

Cable set for measuring voltage at battery terminals. 2 x 5 m (16.4 ft) GA-00210

Clamp-on ammeters

DC clamp-on ammeter, 200 A To measure current in circuit outside TORKEL XA-12992

DC clamp-on ammeter, 1000 A To measure current in circuit outside TORKEL XA-12990

 

BVM

Including:

Dolphin clips, Power & signal connector, Power supply, Connection cables and Carrying case

BVM150 With TORKEL Win software System of 16 BVM units CJ-59092

BVM300 With TORKEL Win software System of 31 BVM units CJ-59093

BVM600 With TORKEL Win software System of 61 BVM units CJ-59096

BVM150 With PowerDB software System of 16 BVM units CJ-59192

BVM300 With PowerDB software System of 31 BVM units CJ-59193

BVM600 With PowerDB software System of 61 BVM units CJ-59196

 

More products MEGGER

MEGGER - B10E

• Reliable and stable a.c. and d.c. power supply for circuit breaker testing
• Continuously variable 24-250 V AC or DC output
• Separate outputs for close coil, trip coil and spring charging motor voltage
• Direct triggering for minimum trip voltage testing

 

MEGGER MPAC208 ACOUSTIC CAMERA FOR GAS LEAKS, MECHANICAL FAULTS AND PARTIAL DISCHARGES

• Pinpoint issues fast
• Quantify leak and energy loss
• Reliable PD insight
• Works in noisy environments
• Optional thermal overlay
• Available in comprehensive kit

 

MICRO-OHMMETER WITH DUALGROUND SAFETY MEGGER - MJOLNER200

• Safer testing using the patented DualGroundâ„¢ technology to test circuit breakers with both sides grounded
• Fully automatic testing- microprocessor controlled
• Wide measuring range and test currents
• High powered and light

 

BOND TESTER MEGGER - BT51

• High test current
• Four terminal measurement
• Two measuring ranges (2000 mO. and 20,00 mO.)and maximum resolution of 0,01 mO.
• Protected against inadvertent connection to the mains supply

 

DIGITAL CLAMP METER MEGGER - DCM310 AND DCM320

• Option of current only , DCM310 or multimeter, DCM320 models
• Measures up to 400 A a.c. with low current ranges for improved resolution
• 600 V a.c./d.c. DCM320
• 20 MO Resistance DCM320

 

KARL FISCHER MOISTURE IN OIL TEST SETS MEGGER ½ KF875 AND KF-LAB MKII

• Coulometric Karl Fischer titrimetry
• KF875 optimized for insulating oil with an SG of 0.875, completely portable
• KF-LAB MkII offers greater flexibility, versatility and sample data input than the KF875; also completely portable
• KF-LAB MkII analyzes materials with an SG between 0.6 & 1.4, plus insulating oils with an SG of 0.875

 

CIRCUIT BREAKER TEST SET MEGGER ½ CB-845

• Digital memory ammeter
• Digital, multirange timer
• Lightweight and portable
• High-current output
• Solid-state output initiate circuitry

 

MEGGER TTR100 TRANSFORMER TURNS RATIO METER, PHASE DISPLACEMENT, VECTOR GROUP, POLARITY

• Tests turns ratio, phase displacement, excitation current, vector group, winding resistance and polarity
• Fully automatic; fast; easy-to-use; handheld; robust; lightweight
• Battery powered with power-saving and shutdown function
• Alphanumeric keyboard
• RS232 for data transfer and printing
• Stores 200 test results and 100 user-defined transformer test settings

 

MEGGER DET14C 1000-761 DET24C 1000-762 EARTH RESISTANCE CLAMP METER

• Elliptical clamp shape improves access to earth cables and straps up to 50 mm
• Low maintenance flat jaw interface
• Measures ground resistance from 0.05 O to 1500 O
• Measures true RMS ground leakage current from 0.5 mA rms to 35 A rms
• CAT IV 600 V safety rating
• Backlit LCD display

 

MEGGER FREJA 400 PROGRAMMA RELAY TEST SYSTEM FREJA400

• FREJA 403 3x60 A at 300 VA per phase.
• FREJA 406 Up to 6 channels: 3 x 60 A and 3 x 15 A
• FREJA 409 Up to 9 channels: 6 x 60 A and 3 x 15 A
• Voltage outputs : Up to four channels 300 V at 150 VA
• Fully automated testing using FREJA Win software
• PC operated or stand alone using the intuitive graphic touch screen
• High current, high power output (60 A / 300 VArms) per phase
• FREJA 409 provides 3 x 120 A in threephase configuration mode
• FREJA 406 provides 6 currents, and FREJA 409 provides 9 currents for transformer differential testing
• IEC 61850 test capabilities