Megger MTO210 Transformer Winding Ohmmeter

Code: Megger MTO210


 

Datasheet PDF, 0.54 Mb
   

Description

• Direct 2-channel digital reading (1 µO to 2000 O)
• DC test current up to 10 A maximum
• 0.25% measurement accuracy
• Integrated demagnetization feature
• Tests operation of on-load tap-changers
• Very fast auto safety discharge circuit 

 

The MTO210 Transformer Ohmmeter is a line-operated, field-portable instrument designed specifically to measure the dc resistance of all types of magnetic windings safely and accurately. It can test transformers and rotating machine windings and perform low-current resistance measurements on connections, contacts and control circuits. 

The Transformer Ohmmeter is extremely useful when testing the windings and contact resistance of tap-changers with "make-before-break" contacts and voltage regulators. This action will check for pitted or misaligned contacts as the instrument will give an indication if either condition occurs.

 

Standard accessories

Transformer Ohmmeter

120/240 volt, 50/60 Hz input MTO210

 

Included Accessories

V1 Potential Lead Set, 60 ft (18 m) 2000-700

V2 Potential Lead Set, 60 ft (18 m) 2000-701

Current Lead Set, 60 ft (18 m) 2000-702

Jumper Lead, 30 ft (9 m) 2000-703

Ground Lead, 15 ft (4.5 m) 4702-7

RS232 Cable for connecting to a PC and Printer CA-RS232

Remote Hand Switch 30915-220

AC Power Cord (IEC60320-C13 to US standard) 17032

AC Power Cord (IEC60320-C13 to Schuko CEE 7/7) 17032-13

Quick Start Guide 37178

Canvas Carrying Bag (for leadset) 30915-211

CAT5e Patch Cable 36798

Instruction Manual ATVMMTO210

PowerDB LITE

 

Recommended options

Optional Accessories

V1 Potential Lead Set, 100 ft (30 m) 2001-403

V2 Potential Lead Set, 100 ft (30 m) 2001-404

Jumper Lead, 50 ft (15 m) 2001-405

Current Lead Set, 100 ft (30 m) 2001-406

Kelvin Lead Set, 60 ft (18 m) 2001-407

Kelvin Lead Set, 100 ft (30 m) 2001-408

Test Lead Set, 60 ft (18 m) including V1, V2,

Current and 30 ft (9 m) Jumper Lead 1001-425

Test Lead Set, 100 ft (30 m) including V1, V2,

Current and 50 ft Jumper Lead 1001-451

Beacon Strobe Light 37181

Printer (includes battery/line powered serial thermal printer)

120 V, 60 Hz 1001-390

230 V, 50 Hz 1001-401

Foam-lined Transit Case 37009

USB to Ethernet Adapter 90001-541

PowerDB (full version) Software,

1st machine license, soft key DB1001

PowerDB (full version) Software,

1st machine license, USB dongle DB1001S

 

 

More products MEGGER

AC VOLTAGE DETECTORS MEGGER - VF3

• Non-contact detection of AC voltage
• Automatic audible warning buzzer
• Bright red voltage indicator in tip
• Ultra bright LED torch

 

MEGGER TRAX MULTIFUNCTION TRANSFORMER TEST SET FOR CAPACITANCE AND DISSIPATION POWER FACTOR

• Replaces the need for multiple test sets
• Powerful, portable and compact system
• Reduces user training and testing time
• Extend the life of power transformers
• 1 Hz insulation condition testing
• Manage and analyse test data

 

MEGGER SMRT33 THREE PHASE RELAY TESTER

• Small, rugged, lightweight and powerful
• Operate with or without a computer
• Intuitive manual operation with Smart Touch View Interface
• High current, high power output - (45 Amps/300 VA rms) per phase
• Network interface provides IEC 61850 test capabilities
• Fully automated testing using AVTS software

 

MEGGER OTS60AF OTS80AF OTS100AF OIL BREAKDOWN TESTER 60KV 80KV 100KV

• Test voltages : 60 kV, 80 kV and 100 kV
• Laboratory instruments for measuring insulating oil breakdown voltage
• Lock in precision - oil vessel with lockable adjustment
• Bright 3.5" colour display
• Suitable for mineral, ester and silicon oils
• Trip detection circuit with direct measurement of voltage and current
• Ultra fast (< 10 µs) HV switch off time

 

MEGGER DET4 DET4T2 DET4TD2 DET4TR2 DET4TC2 DET4TCR2 EARTH GROUND TESTER

• 2, 3 and 4 point testing
• Stakeless (clamp-on) testing capability
• ART (Attached Rod Technique) capability
• Multiple, user selectable test frequencies
• Resistance measurement range to 200 kO
• IP54 rated
• Warning indicators prevent test failure
• Simple one button operation
• Included leads, stakes, calibration certificate and rugged carry case

 

TRMS CLAMP METER MEGGER - DCM1500

• DC and AC current up to 1500 A
• True RMS measurement for greater accuracy
• Large jaw size safely assists with uninsulated conductor measurements
• 750 Vac and 1000 Vdc

 

MEGGER TDR900 TIME DOMAIN REFLECTOMETER & CABLE LENGTH METER

• Full autoranging for measuring the length of power, telephony, CATV and LAN cables, provides distance to an open or short.
• Extra large, high resolution backlit LCD.
• Automatic output impedance control of 25, 50, 75, 100, 125 or 150 ohms.
• User-friendly menu on screen operation.
• Cable length calibration function.
• Internal library of 39 standard cable types.

 

FORK MULTIMETER MEGGER - DCM330

• 200.0 A a.c. open-jaw current measurement
• 0.1 V to 1000 V auto-ranging a.c. and d.c. voltage measurement
• 0.1 O to 20.00 MO resistance range
• Continuity buzzer

 

MEGGER MIT1015 10KV INSULATION RESISTANCE MEGOHMMETER

• RE>Act mode enhanced accuracy and safety
• PI predictor function (PIp)
• Measures up to 20 TΩ
• Up to 3 mA noise rejection

 

ELECTRICIAN'S MULTIMETER MEGGER - AVO210

• 2000 count digital display
• 1000 V DC / 750 V AC ranges
• 10 A AC / DC ranges
• Resistance, frequency and capacitance ranges