Description
• Ground faults in ungrounded dc battery systems easily located
• Operates in high electrical noise environment
• Simplifies fault tracing by identifying fault characteristic (resistive and capacitive) magnitudes
The Battery Ground-Fault Tracer is an economical, manually-balanced instrument that identifies, tracks and locates ground faults in ungrounded dc battery systems - on-line. It is particularly effective in a high electrical noise environments, as the strength of the test current can be adjusted.
The Battery Ground-Fault Tracer accelerates fault location by eliminating trial-and-error procedures and because faults can be located without going off-line. It is particularly useful in any industry where supply of power for operating measurement, communication and control equipment is critical.
Standard accessories
Battery Ground Fault Tracer,120/240 V ac, 50/60 Hz, CE-marked 246100B
Included Accessories
Fused source leads, 20 ft (6 m) [1 pr] 29386-3
Current transformer, 2 in. (5 cm) with leads, 4 ft (1.2 mm) [1 pr] 29999-1
AC power cord, 6 ft (1.8 m) [1] 17032-7
Feedback cable, 40 ft (12 m) [1] 29998
Padded accessory bag [1] 29996
Battery, 9 volt [1] 1482-1
Operator’s manual [1] AVTM246100B
Optional Accessories
Mini-CT, 0.5 in. (12 mm) with 4.25 ft (1.3 m) lead 30595
Recommended options
More products MEGGER
|
PRIMARY CURRENT INJECTION TEST SYSTEM MEGGER ODEN AT
• Most advanced primary current injection test system to simplify all types of switchgear and CT commissioning, ground grid, circuit breaker testing and more
|
|
MEGGER FREJA 300 PROGRAMMA RELAY TESTER CF-19091
• can generate 4x150 V (82 VA) and 3x15 A (87 VA) or 1x45 A (250 VA). |
|
MEGGER TTRU1 TRANSFORMER TURN RATIO TESTER
• Battery operated with USB-C rechargeablenAA NiMH batteries included
|
|
FREQUENCY RESPONSE ANALYZER MEGGER FRAX200 FRAX150 FOR POWER TRANSFORMER
• High dynamic range and accuracy
|
|
MEGGER TDR2000/2 TDR CABLE REFLECTOMETER FAULT LOCATOR TDR2000/2RM TDR2000/2R
• 20 km range at VF = 0.90 |
|
BATTERY GROUND FAULT LOCATOR MEGGER - BGL
• Ground faults in ungrounded dc battery systems easily located
|
|
MEGGER MPRT2145 SINGLE PHASE RELAY TESTER
• Open communication architecture for third party software application |
|
MEGGER DLRO200 DUCTOR MICRO-OHMMETER 200A 6220-755
• Small and weighs less than 15kg |
|
MEGGER MIT2500 2.5KV INSULATION TESTER
• Insulation testing up to 2.5 kV and 200 GΩ range in a handheld instrument
|
|
CURRENT SUPPLY UNIT MEGGER ½ CSU600A AND CSU600AT
• Compact and rugged
|