Megger BGFT 246100B Battery Ground Fault Tracer

Code: Megger BGFT 246100B


 

Datasheet PDF, 0.52 Mb

Description

• Ground faults in ungrounded dc battery systems easily located 
• Operates in high electrical noise environment 
• Simplifies fault tracing by identifying fault characteristic (resistive and capacitive) magnitudes 

 

The Battery Ground-Fault Tracer is an economical, manually-balanced instrument that identifies, tracks and locates ground faults in ungrounded dc battery systems - on-line. It is particularly effective in a high electrical noise environments, as the strength of the test current can be adjusted.

The Battery Ground-Fault Tracer accelerates fault location by eliminating trial-and-error procedures and because faults can be located without going off-line. It is particularly useful in any industry where supply of power for operating measurement, communication and control equipment is critical.

 

Standard accessories

Battery Ground Fault Tracer,120/240 V ac, 50/60 Hz, CE-marked 246100B

Included Accessories

Fused source leads, 20 ft (6 m) [1 pr] 29386-3

Current transformer, 2 in. (5 cm) with leads, 4 ft (1.2 mm) [1 pr] 29999-1

AC power cord, 6 ft (1.8 m) [1] 17032-7

Feedback cable, 40 ft (12 m) [1] 29998

Padded accessory bag [1] 29996

Battery, 9 volt [1] 1482-1

Operator’s manual [1] AVTM246100B

                                      

Optional Accessories

Mini-CT, 0.5 in. (12 mm) with 4.25 ft (1.3 m) lead 30595

 

Recommended options

 

 

More products MEGGER

MEGGER DLRO2X PORTABLE CONPACT 2A MICROHMMETER

• The DLRO2X is a robust 2 A low resistance ohmmeter
• designed for precise, reliable measurements across various applications, including industrial, railway, and avionic sectors

 

MEGGER EGIL BREAKER ANALYZER BM-19090 BM-19093 BM-19095

• Suitable for testing timing and travel on all circuit breakers with single interrupter per phase
• Extremely easy-to-use and reliable
• Two separate timing channels for measurement of auxiliary contacts
• Analog measurement channels for travel transducers or general voltage/current measurements
• Static and dynamic resistance measurements along with the SDRM201 accessory

 

MEGGER MIT2500 2.5KV INSULATION TESTER

• Insulation testing up to 2.5 kV and 200 GΩ range in a handheld instrument
• Guard terminal for high resistance accuracy
• Adjustable insulation test voltage from 50 V to 2500 V
• Stabilised insulation test voltage

 

MEGGER OTS60AF OTS80AF OTS100AF OIL BREAKDOWN TESTER 60KV 80KV 100KV

• Test voltages : 60 kV, 80 kV and 100 kV
• Laboratory instruments for measuring insulating oil breakdown voltage
• Lock in precision - oil vessel with lockable adjustment
• Bright 3.5" colour display
• Suitable for mineral, ester and silicon oils
• Trip detection circuit with direct measurement of voltage and current
• Ultra fast (< 10 µs) HV switch off time

 

MEGGER SMRT1 SINGLE PHASE RELAY TESTER

• Small, rugged, lightweight and powerful
• Operate with or without a computer
• Intuitive manual operation with Smart Touch View Interface
• High current, high power (75 Amps/400 VA rms)
• Network interface provides IEC 61850 test capabilities
• Fully automated testing using AVTS software

 

MEGGER TDR500/3 TIME DOMAIN REFLECTOMETER & CABLE FAULT LOCATOR 1002-227

• minimum resolution of 0.1 m and a 5 km maximum range
• Simple operation.
• AUTO selection of gain and pulse width.
• Ultra fast pulse for near end fault identification.
• Trace HOLD feature.
• IP54 rating offers real life working.
• Designed for use on all metallic cable pairs.

 

MEGGER TDR1000/3P TDR CABLE FAULT LOCATOR

• TDR1000/3P is suitable for use on both dead or live cables
• Simple operation
• AUTO set up for instant use
• Ultra fast pulse for near end fault identification
• Trace HOLD feature to allow comparison between cables
• IP54 rating offers real life working
• No blocking filters require
• Supplied with fused test leads

 

MEGGER DLRO10X RESISTANCE OHMMETER DLRO 10 DLRO 10X 6111-428 6111-429

• up to 10A current
• Accurate results in under three seconds
• Auto current reversal cancels standing emfs
• Fuse protected to 600 V
• NiMH battery reduces weight
• 250 mW power limit (with optional override) to avoid heating the test sample

 

COMBINED LOOP AND RCD TESTERS MEGGER - LRCD210 AND LRCD220

• Non-trip loop tester
• RCD testing from 10 mA to 1000 mA
• Extremely easy and safe to use
• Built-in protective front cover

 

PHOTOVOLTAIC KIT MEGGER - PVK320

• PVM210 irradiance meter
• AVO410 CATIV TRMS multimeter
• C4 solar connectors to 4 mm standard plug test leads
• MC3 to MC4 adapter test leads
• PV kit storage pouch