This instrument was developed to detect, track and locate ground faults on battery systems - without resorting to sectionalizing! Model BGL tracks and locates ground faults on live or dead battery systems. To save hours of unnecessary troubleshooting, the BGL readily differentiates between the resistive fault currents and capacitive charging currents. This feature allows the instrument to detect and track leakage paths, even in the presence of surge-suppression capacitors.

 

Features:

  • Ground faults in ungrounded dc battery systems easily located
  • Operates in high electrical noise environment
  • Simplifies fault tracing by identifying fault characteristic (resistive and capacitive) magnitudes
 

More products MEGGER

MEGGER MTK310 MTK320 MTK330 ELECTRICAL INSTALLATION TEST KITS

• Three kit options available: Insulation, continuity, earth loop, RCD testing
• MTK310: Standard electrical test kit
• MTK320: Advanced electrical test kit
• MTK330: Result storage and downloading test kit
• Rubber armoured instruments
• Weatherproof IP54
• Test leads included
• Calibration certificates included
• 3 year warranty

 

MEGGER TDR1000/3P TDR CABLE FAULT LOCATOR

• TDR1000/3P is suitable for use on both dead or live cables
• Simple operation
• AUTO set up for instant use
• Ultra fast pulse for near end fault identification
• Trace HOLD feature to allow comparison between cables
• IP54 rating offers real life working
• No blocking filters require
• Supplied with fused test leads

 

MEGGER SMRT1 SINGLE PHASE RELAY TESTER

• Small, rugged, lightweight and powerful
• Operate with or without a computer
• Intuitive manual operation with Smart Touch View Interface
• High current, high power (75 Amps/400 VA rms)
• Network interface provides IEC 61850 test capabilities
• Fully automated testing using AVTS software

 

MEGGER IDAX-300 IDAX-350 INSULATION DIAGNOSTIC ANALYZER, TAN DELTA, POWER FACTOR

• Automated measurement and analysis of moisture content, tan delta/power factor and oil conductivity
• Individual temperature correction (ITC) of tan delta/power factor and oil conductivity
• 40% faster measurements with the new IDAX 5.0 SW
• Reliable measurements in high-interference environments
• Multi-function test set for transformer measurements

 

MEGGER TDR500/3 TIME DOMAIN REFLECTOMETER & CABLE FAULT LOCATOR 1002-227

• minimum resolution of 0.1 m and a 5 km maximum range
• Simple operation.
• AUTO selection of gain and pulse width.
• Ultra fast pulse for near end fault identification.
• Trace HOLD feature.
• IP54 rating offers real life working.
• Designed for use on all metallic cable pairs.

 

MEGGER MOM2 220A MICROHMMETER BD-59090 BD-59092 BD-59093

• Up to 220 A
• Battery powered
• Light weighs only 1 kg
• Safe test - DualGround™
• Auto range: 1 µO to 1000 mO
• Bluetooth® PC communication
• Complies with IEEE and IEC standards

 

MEGGER DET4 DET4T2 DET4TD2 DET4TR2 DET4TC2 DET4TCR2 EARTH GROUND TESTER

• 2, 3 and 4 point testing
• Stakeless (clamp-on) testing capability
• ART (Attached Rod Technique) capability
• Multiple, user selectable test frequencies
• Resistance measurement range to 200 kO
• IP54 rated
• Warning indicators prevent test failure
• Simple one button operation
• Included leads, stakes, calibration certificate and rugged carry case

 

MEGGER DET2/3 HIGH RESOLUTION ACCURACY EARTH TEST SET

• High resolution of 1 mΩ, ideal for large earth systems
• Versatile tests modes
• High accuracy for earth/ground electrode grid and soil resistivity tests
• Rechargeable battery power that can last all day with a fast re-charge (up to 10 hours)
• Robust instrument with IP65 protection
• Automatic test frequency selection, with filters and high current features
• Diagnostic trace display
• Data storage
• Large colour display that shows numeric and graphical results

 

MEGGER TORKEL-840 TORKEL-860 BS-49094 BS-49096 TELECOM BATTERY LOAD DISCHARGE TESTER FOR UPS CELLS

• used for battery systems ranging from 12 to 250 V
• Batteries can be tested "in service"
• Unit adjusts to include load currents in the test parameters
• User adjustable alarm and shutdown points to avoid excessive discharge
• Easily expandable for larger battery banks using TXL extra load units (option)
• Computerized test operation using TorkelWin software (option)

 

CIRCUIT BREAKER TEST SET MEGGER ½ CB-845

• Digital memory ammeter
• Digital, multirange timer
• Lightweight and portable
• High-current output
• Solid-state output initiate circuitry