Megger TDR1000/3P TDR cable fault locator

Code: Megger TDR1000/3P


 

Datasheet PDF, 0.14 Mb

Description

• Simple operation
• AUTO set up for instant use
• Ultra fast pulse for near end fault identification
• Trace HOLD feature to allow comparison between cables
• IP54 rating offers real life working
• No blocking filters require
• Supplied with fused test leads

 

A state-of-the-art single channel TDR capable of indentifying and locating faults on metalic cables. The TDR1000/3P is suitable for use on both dead or live cables

 

Standard accessories

Time Domain Reflectometer TDR1000/3P

Included accessories

Hard carry case 5410-420

Fused test lead set 1002-015

User guide CD 2002-178

 

Optional accessories

Miniature clip test lead set 6231-652

 

More products MEGGER

MEGGER TTR300 TTR310 TTR330 THREE-PHASE TRANSFORMER TURNS RATIO METER

• Stand-alone or remote-control operation
• Accurately measures ratio, phase deviation and excitation current
• Field upgradeable without compromise to calibration
• Built-in capability for storing and downloading test results in an XML format, via RS-232, Ethernet or USB ports (depending on model)
• Works in the presence of high interference/high voltage
• Highest ratio measurement (45,000:1); highest accuracy (0.1%)
• Displays % error vs. name plate with pass/fail limits

 

MULTIFUNCTION INSTALLATION TESTERS MEGGER - MFT1735

• Two and three wire non-trip loop testing for RCD protected circuits
• Type-B RCD and 3-phase RCD testing for industrial applications with no Earth
• 3-terminal earth test and stakeless testing for earth electrode resistance measurement **
• Internal memory and Bluetooth® communications

 

MEGGER MIT515/2 5KV INSULATION RESISTANCE MEGOHMMETER

• RE>Act mode enhanced accuracy and safety
• PI predictor function (PIp)
• Measures up to 20 TΩ
• Up to 3 mA noise rejection

 

MEGGER TORKEL 820 BS-49092 TELECOM BATTERY LOAD DISCHARGE TESTER PROGRAMMA

• Combines efficiency with portability
• Batteries can be tested "in service"
• Discharge 24 and 48 V batteries at a current of 270 A
• 12 V batteries at 135 A
• Two or more TORKEL 820 units and/or extra load units TXL, can be linked together if you need higher current.

 

MEGGER TRAX MULTIFUNCTION TRANSFORMER TEST SET FOR CAPACITANCE AND DISSIPATION POWER FACTOR

• Replaces the need for multiple test sets
• Powerful, portable and compact system
• Reduces user training and testing time
• Extend the life of power transformers
• 1 Hz insulation condition testing
• Manage and analyse test data

 

MEGGER TTRU1 TRANSFORMER TURN RATIO TESTER

• Battery operated with USB-C rechargeablenAA NiMH batteries included
• Pass/Fail ratio evaluation
• Automatic results storage
• USB drive save and export
• Full colour Hi-bright LCD screen
• Additive / Subtractive polarity detection
• Excitation current

 

MICRO-OHMMETER MEGGER MOM690A

• Easy-to-use
• Automatic range settings
• MOM Win PC software

 

INSTRUMENT TEST BOX MEGGER - MTB7671/2

• The only one that fully tests your instruments to the regs.
• Tests the full range of your tester½s capability not just what½s easy
• Won½t trip RCD protected circuits
• Checks insulation, continuity, loop and RCD functions of testers
• Works with all testers for Part P Certification

 

UNIVERSAL CIRCUIT BREAKER TEST SETS MEGGER PS-9130 AND PS-9160

• Proven power train
• Rugged instrumentation and controls
• Direct connection of draw-out type breakers
• Integral clock/calendar
• Easy-to-read display

 

MULTI-AMP CIRCUIT BREAKER TESTER RETROFIT MEGGER DDA16, DDA30 AND DDA60

• Drop-in retrofit capability to the Multi-Amp Model CB-9116, Model DB-8130 and Model CB-8160 circuit breaker test sets
• Digital Signal Processing (DSP) technology
• Variable pulse time and firing-angle output-current control
• Complies with NEMA AB-4 Test Guidelines