Megger DET4 DET4T2 DET4TD2 DET4TR2 DET4TC2 DET4TCR2 Earth Ground Tester

Code: Megger DET4 DET4T2 DET4TD2 DET4TR2 DET4TC2 DET4TCR2


 

Datasheet PDF, 0.49 Mb
       

Description

• 2, 3 and 4 point testing
• Stakeless (clamp-on) testing capability
• ART (Attached Rod Technique) capability 
• Multiple, user selectable test frequencies
• Resistance measurement range to 200 kO
• IP54 rated
• Warning indicators prevent test failure
• Simple one button operation
• Included leads, stakes, calibration certificate and rugged carry case

 

 

The DET4 contractor series includes --
• DET4TD2: Dry-cell battery powered basic 4-terminal tester
• DET4TR2: Rechargeable battery powered basic 4-terminal tester
• DET4TC2: Dry-cell battery powered 4-terminal tester with selectable test frequencies, greater measurement sensitivity and attached rod technique and stakeless measurement capability
• DET4TCR2: Rechargeable battery powered 4-terminal tester with selectable test frequencies, greater measurement sensitivity and attached rod technique and stakeless measurement capability

The DET4TD, DET4TC and DET4TCR replace the DET5/4R and DET5/4D.

 

 

Standard accessories

  • DET4TD2 1000-347
  • DET4TR2 1000-324
  • DET4TC2 1000-345
  • DET4TC2+Clamps 1000-365
  • DET4TC2+Kit 1000-404
  • DET4TCR2 1000-346
  • DET4TCR2+Clamps 1000-366
  • DET4TCR2+Kit 1000-405
 

Recommended options

Optional Accessories

  • Current measuring clamp and connecting lead for ART testing method ICLAMP
  • Voltage inducing clamp, calibration check PCB
  • (two-clamp measurements) and connecting lead VCLAMP
  • Calibration check box 6220-824
  • Right angled terminal adaptor set 6220-803
  • Auxiliary 12V socket charger (DET4TR2 and DET4TCR2 only) 6280-375
  • Standard accessory kit (leads, rods, canvas accessory case for leads & rods) 250579
  • Deluxe accessory kit (leads, rods, padded case) 250581
  • Standard accessory kit (hammer, spikes, leads) 6310-755
  • Professional ground testing kit (2 x 50m, 2 x 30m, 4 auger stakes, carry case) 6320-245
  • Soil resistivity kit (leads, rods, padded case) 250586
  • "Getting Down to Earth" a Megger guide to earth testing AVTM25-TA
  • Replacement hard carry case 5410-429
  • Replacement calibration check PCB (two-clamp measurements) 6220-831
  • Replacement ground test stakes (x2) for included kit (200mm, 8mm dia) 6220-804
  • Replacement ground test leads (x4) for included kit (15m, 10m, 10m, 3m) 6220-806
  • Replacement auger stakes (x2) for professional kit 6220-839
  • Replacement cable reel (50m, red cable) for professional kit 6220-840
  • Replacement cable reel (50m, black cable) for professional kit 6220-841
  • Replacement cable reel (30m, green cable) for professional kit 6220-843
  • Replacement cable reel (30m, yellow cable) for professional kit 6220-842
 

More products MEGGER

MEGGER SMRT410 RELAY TEST SYSTEM

• Small, rugged, lightweight and powerful
• Operates with or without a computer
• Intuitive manual operation with Smart Touch View Interface
• High current, high power output (60 Amps/300 VA rms) per phase
• Flexible output design provides up to 4-phase voltage and up to 10-phase current
• Network interface provides IEC 61850 test capabilities
• Fully automated testing using AVTS software

 


MEGGER DELTA4110 INSULATION POWER & DISSIPATION FACTOR TEST SET DELTA4000

• fully automatic 12 kV insulation power factor / dissipation factor (tan delta) test set
• Voltage: 25 V to 12 kV, 1 V resolution
• Current : 0 to 5 Amps, 0.1 µA maximum resolution
• Capacitance: 0 to 100 µF, 0.01 pF maximum resolution
• Inductance: 6 H to 10 MH, 0.1 mH maximum resolution
• Power factor PF : 0-100% (0-1), 0.001% maximum resolution
• Dissipation factor DF : 0-100 (0-10,000%), 0.001% maximum resolution
• Watt Loss: 0 to 2 kW
• Automatic and manual operation
• Accurate and repeatable measurement results with high noise suppression
• Lightweight, rugged two-piece design

 

MEGGER FREJA 306 PROGRAMMA RELAY TESTER CF-29091

• current outputs, higher amps (3 x 15 A + 3 x 35 A), VA or compliance voltage.
• test differential relays with 6 currents, or virtually any single or 3-phase relay
• For secondary testing of protection relays
• Can be used stand-alone or with a PC
• Flexble, can test many relay types
• Lightweight and portable
• Greatest possible precision

 

MEGGER DLRO600 DUCTER MICRO-OHMMETER 600A

• Small and weighs less than 33 lbs (15 kg)
• Test currents from 10 A to 600 A dc
• 0.1 µohms best resolution
• On board memory for up to 300 test results and notes
• RS232 port to download stored results or for real time output to a printer
• Supplied complete with 16.4 ft (5 m) test leads and download software

 

MEGGER DELTA4310 INSULATION POWER & DISSIPATION FACTOR TEST SET DELTA 4310

• fully automatic 12 kV insulation power factor / dissipation factor (tan delta) test set
• Voltage: 25 V to 12 kV, 1 V resolution
• Current : 0 to 5 Amps, 0.1 µA maximum resolution
• Capacitance: 0 to 100 µF, 0.01 pF maximum resolution
• Inductance: 6 H to 10 MH, 0.1 mH maximum resolution
• Power factor PF : 0-100% (0-1), 0.001% maximum resolution
• Dissipation factor DF : 0-100 (0-10,000%), 0.001% maximum resolution
• Watt Loss: 0 to 2 kW
• Automatic and manual operation
• Accurate and repeatable measurement results with high noise suppression
• Lightweight, rugged two-piece design

 

STATIC / DYNAMIC RESISTANCE MEASUREMENT ACCESSORY FOR TM SERIES MEGGER - SDRM202

• Enables resistance measurement on circuit breakers
• Small and light weight
• A number of operations can be run with short waiting intervals

 

AC VOLTAGE DETECTORS MEGGER - VF3

• Non-contact detection of AC voltage
• Automatic audible warning buzzer
• Bright red voltage indicator in tip
• Ultra bright LED torch

 

BATTERY IMPEDANCE TESTER MEGGER - BITE2 AND BITE2P

• Determines condition of lead-acid and NiCd cells up to 7000 Ah
• On-board Pass/Warning/Fail indications
• Robust, repeatable instruments
• On-line testing

 

MEGGER MIT400/2 MIT410/2 MIT420/2 MIT430/2 CAT IV INSULATION TESTER WITH 1000V

• nsulation testing up to 1000 V and 200 GΩ range
• Stabilised insulation test voltage (New)
• Single range, faster continuity testing from 0.01 Ω to 1 MΩ (New)
• 600 V T RMS AC and DC voltage measurement