Circuit Breaker Test Set Megger ½ CB-845

Code: Megger � CB-845


 

Datasheet PDF, 0.04 Mb

Description

The CB-845 test set is a high-current circuit breaker test set consisting of a control unit that incorporates the latest in solid-state metering, control technology and a high-current output unit.

 

The lightweight, two-section design of Model CB-845 enables the user to easily transport the unit into areas previously inaccessible to high-current test equipment such as elevated or subsurface load centers, shipboard power panels, elevator machinery rooms and other isolated locations.

 

Features:

  • Digital memory ammeter
  • Digital, multirange timer
  • Lightweight and portable
  • High-current output
  • Solid-state output initiate circuitry
 

More products MEGGER

COMBINED LOOP AND RCD TESTERS MEGGER - LRCD210 AND LRCD220

• Non-trip loop tester
• RCD testing from 10 mA to 1000 mA
• Extremely easy and safe to use
• Built-in protective front cover

 

PRIMARY CURRENT INJECTION TEST SYSTEM MEGGER ODEN AT

• Most advanced primary current injection test system to simplify all types of switchgear and CT commissioning, ground grid, circuit breaker testing and more
• Modular design to permit optimal user configuration of output current vs. unit size
• Compact transport cart facilitates portability into switchgear rooms with limited space
• Unique I/30 function allows the current to be pre-set using low current to prevent test sample heating, thus eliminating corruption of test result

 

MEGGER MPQ2000 POWER ENERGY QUALITY ANALYZER CLASS-A

• Powered off of phase A voltage AC/DC
• Weatherproof to IP54 standard for use in any environment
• 1000 VAC and 1500 VDC range
• Auto CT identifies the current that the instrument is connected to and the range that it is in
• Real time scope and DVM
• IEC61000-4-30 Class A compliance

 

MEGGER DLRO200 DUCTOR MICRO-OHMMETER 200A 6220-755

• Small and weighs less than 15kg
• Test currents from 10 A to 200 A d.c.
• 0.1 µO best resolution
• On board memory for up to 300 test results and notes
• RS232 port to download stored results or for real time output to a printer
• Supplied complete with 5m test leads and download software

 

MEGGER MOM2 220A MICROHMMETER BD-59090 BD-59092 BD-59093

• Up to 220 A
• Battery powered
• Light weighs only 1 kg
• Safe test - DualGround™
• Auto range: 1 µO to 1000 mO
• Bluetooth® PC communication
• Complies with IEEE and IEC standards

 

MEGGER - B10E

• Reliable and stable a.c. and d.c. power supply for circuit breaker testing
• Continuously variable 24-250 V AC or DC output
• Separate outputs for close coil, trip coil and spring charging motor voltage
• Direct triggering for minimum trip voltage testing

 

MEGGER TTR300 TTR310 TTR330 THREE-PHASE TRANSFORMER TURNS RATIO METER

• Stand-alone or remote-control operation
• Accurately measures ratio, phase deviation and excitation current
• Field upgradeable without compromise to calibration
• Built-in capability for storing and downloading test results in an XML format, via RS-232, Ethernet or USB ports (depending on model)
• Works in the presence of high interference/high voltage
• Highest ratio measurement (45,000:1); highest accuracy (0.1%)
• Displays % error vs. name plate with pass/fail limits

 

MEGGER MIT480/2 MIT481/2 MIT485/2 INSULATION TESTER FOR COMMUNICATIONS 500V

• Insulation testing up to 500 V and 100 GΩ range in a hand held instrument
• 3-wire connection for A, B, and E (Tip, Ring and Ground/Earth) connection
• Gated access to 500 V to prevent accidental damage
• CAT IV 600 V and IP 54

 

MICROPROCESSOR-BASED CIRCUIT BREAKER TEST SETS MEGGER PS-9116

• Portable, three piece chassis
• Tests wide range of air-frame breakers
• Test result printout capability

 

MEGGER OTS60AF OTS80AF OTS100AF OIL BREAKDOWN TESTER 60KV 80KV 100KV

• Test voltages : 60 kV, 80 kV and 100 kV
• Laboratory instruments for measuring insulating oil breakdown voltage
• Lock in precision - oil vessel with lockable adjustment
• Bright 3.5" colour display
• Suitable for mineral, ester and silicon oils
• Trip detection circuit with direct measurement of voltage and current
• Ultra fast (< 10 µs) HV switch off time