TRMS Clamp Meter Megger - DCM1500

Code: Megger - DCM1500


 

Datasheet PDF, 0.16 Mb
 

Description

Safety rated to IEC 61010-1 CAT IV 600 V, the DCM1500 Measures up to 1500 A ac or dc and it offers 750 Vac and 1000 Vdc ranges making it ideal for use in the installation, maintenance, monitoring or checking of large ac or dc electrical systems and equipment.

 

The large clear digits of the numeric display are complemented by a high-resolution digital bar graph, useful for trending and indicating fluctuation in measurement. The back light assists use in poorly lit areas such as distribution cupboards and corners of switch-rooms; and the data-hold feature enables use on difficult access cables, where otherwise the display may be impossible to see.

 

Features:

  • DC and AC current up to 1500 A
  • True RMS measurement for greater accuracy
  • Large jaw size safely assists with uninsulated conductor measurements
  • 750 Vac and 1000 Vdc
  • Resistance , continuity and frequency
  • Peak, min/max and data-hold functions
 

More products MEGGER

MEGGER TORKEL 820 BS-49092 TELECOM BATTERY LOAD DISCHARGE TESTER PROGRAMMA

• Combines efficiency with portability
• Batteries can be tested "in service"
• Discharge 24 and 48 V batteries at a current of 270 A
• 12 V batteries at 135 A
• Two or more TORKEL 820 units and/or extra load units TXL, can be linked together if you need higher current.

 

MEGGER MPQ2000 POWER ENERGY QUALITY ANALYZER CLASS-A

• Powered off of phase A voltage AC/DC
• Weatherproof to IP54 standard for use in any environment
• 1000 VAC and 1500 VDC range
• Auto CT identifies the current that the instrument is connected to and the range that it is in
• Real time scope and DVM
• IEC61000-4-30 Class A compliance

 

COMBINED LOOP AND RCD TESTERS MEGGER - LRCD210 AND LRCD220

• Non-trip loop tester
• RCD testing from 10 mA to 1000 mA
• Extremely easy and safe to use
• Built-in protective front cover

 

MEGGER TDR2000/2 TDR CABLE REFLECTOMETER FAULT LOCATOR TDR2000/2RM TDR2000/2R

• 20 km range at VF = 0.90
• Monochrome or colour options
• Primary cell or rechargeable options
• Large back lit LCD Display
• Dual cursor measurement
• Intermittent fault location
• Output pulse amplitude and width control
• Trace Master PC software included
• IP54 Rating
• 2 year Warranty

 

MEGGER VLOC3-PRO CABLE UTILITY TRACE LOCATOR

• Color-coded EM distortion warnings
• Offset locate modes - Vector and Plan View
• Cloud-based data warehousing
• Internal data logging
• Optional Bluetooth connectivity

 

MEGGER IDAX-300 IDAX-350 INSULATION DIAGNOSTIC ANALYZER, TAN DELTA, POWER FACTOR

• Automated measurement and analysis of moisture content, tan delta/power factor and oil conductivity
• Individual temperature correction (ITC) of tan delta/power factor and oil conductivity
• 40% faster measurements with the new IDAX 5.0 SW
• Reliable measurements in high-interference environments
• Multi-function test set for transformer measurements

 

MULTIFUNCTION INSTALLATION TESTERS MEGGER - MFT1731, MFT1721 AND MFT1711

• Phase rotation indication for verification of rotating machinery
• 3-phase RCD testing for industrial applications with no earth
• Suite of earths test for electrode resistance measurement
• On-board data storage and Bluetooth® download

 

MEGGER TTRU1 TRANSFORMER TURN RATIO TESTER

• Battery operated with USB-C rechargeablenAA NiMH batteries included
• Pass/Fail ratio evaluation
• Automatic results storage
• USB drive save and export
• Full colour Hi-bright LCD screen
• Additive / Subtractive polarity detection
• Excitation current

 

MEGGER MIT1025/2 10KV INSULATING RESISTANCE MEGOMETER

• Diagnostic testing with full test suite
• PI Predictor™ cuts test time in half
• Accurate testing with RE>Act™
• Built-in storage and easy data export
• Designed for safe testing in the field

 

MEGGER GOOSER IEC 61850 RELAY TESTER

• Reliable testing of IEC61850 relays using a conventional relay test set
• Separate Ethernet ports for the substation LAN and the controlling PC forming a Safe Substation Bus Access Point
• Seamless interaction between SCL GOOSE and GOOSE "sniffing"
• GOOSE merge - SCL GOOSE vs captured GOOSE for network troubleshooting and SCD file validation at FAT
• Stand alone functionality - Download a configuration and run