RF Resistance Standard for calibration of LCR Meters Meatest M530

Code: Meatest M530


 

Datasheet PDF, 0.2 Mb
   

Description

  • Resistance range 10 O to 1000 O
  • Very low frequency dependency
  • Applicable frequency range to 100 MHz
  • Calibration of wide frequency range LCR meters

 

Description

The resistance standard set is designed especially for calibration of LCR meters in frequency range from DC to 100 MHz. The standards are equipped with four coaxial BNC connectors. Wide frequency range is achieved by applied HF design using strip line technology. Four-pair terminal connection with 22 mm distance between them enables direct connection to the UUTs without need to apply test leads.

The standards are available with nominal values 10 O, 50 O, 100 O, 500 O, 1000 O in 1% tolerance. Reference positions OPEN and SHORT for easy "zero" compensation are available as well.

 

Recommended options

M530-10R 10?

M530-50R 50?

M530-100R 100?

M530-500R 500?

M530-1000R 1000?

OPEN - -

SHORT 0

 

More products MEATEST

HIGH PRECISION MULTIFUNCTION CALIBRATOR MEATEST M142

• 15ppm Accuracy
• DC/AC voltage up to 1000 V
• DC/AC current up to 30 A
• Resistance up to 1000 MO, capacitance up to 100 uF
• TC/RTD temperature sensors simulation
• Frequency output up to 20 MHz
• Electric power up to 240 V / 20 A
• Built-in process multimeter
• GPIB & RS232 interface

 

CAPACITANCE DECADE FOR CALIBRATION LCR-METERS MEATEST M520

• Designed for RCL meters calibration
• Range of capacitance from 100 pF to 12 mF
• Basic accuracy 0.25 %
• Maximal operating voltage 50 V
• Power supplying from internal battery or power line adapter
• Remote control RS-232

 

RTD SIMULATOR OF TEMPERATURE CONTROLLERS PT100, PT200, PT500, PT1000, NI100, NI1000 MEATEST M612

• Calibration of temperature controllers
• Resistance range from 16 O to 10 kO
• Simulation of Pt and Ni sensors
• Accuracy +/- 0.02°C
• Temperature stability < 1 ppm/°C
• Simulation of cable resistances
• Interface RS 232 (IEEE488 optionally)

 

10KV HIGH RESISTANCE DECADE FOR CALIBRATING MEGOHMMETERS AND INSULATION TESTERS MEATEST M191

• Total resistance range 10.00 k? to 1000.0 G?
• Resistance accuracy 0.1 to 5 %
• Test voltage range 10 000 VDC + 5%
• Test voltage accuracy indication 0.5 % + 10 V
• Test current indication 4 digit from 0.01 pA to 99.99 mADC
• Programmable high resistance decade box
• Short current verification
• Dielectric and absorption parameters simulation: polarization index (PI), dielectric absorption ratio (DAR) and polarization ratio (PR)
• High voltage capacitance in three fix points 10, 50, 100 nF
• HIPOT timer verification

 

POWER AND ENERGY CALIBRATOR MEATEST M133

• Voltage "phase-neutral" 1 V to 280 Vdc / 300 mA, 1 V to 600 Vac
• AC voltage "phase - phase" in the 3phase system 2 V to 1200 V
• DC/AC current 8 mA to 30 A / 5 V
• Power factor setting -1 to +1
• Harmonic, interharmonic distortion, modulation
• Frequency range 15 Hz to 1 kHz
• Simulated electric power to 8.4 kVA (420 kVA with option 140-50)
• Built-in process multimeter
• GPIB & RS232 interface

 

POWER AND ENERGY CALIBRATOR MEATEST M133I

• Voltage "phase-neutral" 1 V to 280 Vdc / 300 mA, 1 V to 600 Vac
• AC voltage "phase - phase" in the 3phase system 2 V to 1200 V
• DC/AC current 30 mA to 30 A / 5 V, accuracy 310 ppm
• Power factor setting -1 to +1
• Frequency range 15 Hz to 1 kHz
• Simulated electric power up to 8.4 kVA (420 kVA with option 140-50)
• Built-in process multimeter
• GPIB & RS232 interface

 

LCR IMPEDANCE CALIBRATOR OF RESISTANCE, CAPACITANCE, INDUCTANCE MEATEST M550

• Resistance standards from 0.1 O to 100 MO
• Capacitance standards from 10 pF to 100 µF
• Simulated inductance standards from 10 µH to 10 H
• Four pair coaxial terminal connection, four terminal connection, two terminal connection
• Calibration data from 20 Hz to 1 MHz
• Interface bus GPIB and RS232 as standard

 

RESISTIVE DECADE BOX MEATEST M602

• Resistance range from 0.1 O to 10 MO with accuracy 0.02 %
• Temperature coefficient < 25 ppm/°C
• Max. load 2 W (120 V and 0.6 A)
• RTD (Pt, Ni) simulation with accuracy 0.2 °C
• Power supplying from power line adaptor or from internal battery
• Interface RS232 (IEEE488 optionally)
• Table version (19" module as option)

 

LCR IMPEDANCE CALIBRATOR OF RESISTANCE, CAPACITANCE, INDUCTANCE MEATEST M550

• Resistance standards from 0.1 O to 100 MO
• Capacitance standards from 10 pF to 100 µF
• Simulated inductance standards from 10 µH to 10 H
• Four pair coaxial terminal connection, four terminal connection, two terminal connection
• Calibration data from 20 Hz to 1 MHz
• Interface bus GPIB and RS232 as standard

 

RF RESISTANCE STANDARD FOR CALIBRATION OF LCR METERS MEATEST M530

• Resistance range 10 O to 1000 O
• Very low frequency dependency
• Applicable frequency range to 100 MHz
• Calibration of wide frequency range LCR meters