RF Resistance Standard for calibration of LCR Meters Meatest M530

Code: Meatest M530


 

Datasheet PDF, 0.2 Mb
   

Description

  • Resistance range 10 O to 1000 O
  • Very low frequency dependency
  • Applicable frequency range to 100 MHz
  • Calibration of wide frequency range LCR meters

 

Description

The resistance standard set is designed especially for calibration of LCR meters in frequency range from DC to 100 MHz. The standards are equipped with four coaxial BNC connectors. Wide frequency range is achieved by applied HF design using strip line technology. Four-pair terminal connection with 22 mm distance between them enables direct connection to the UUTs without need to apply test leads.

The standards are available with nominal values 10 O, 50 O, 100 O, 500 O, 1000 O in 1% tolerance. Reference positions OPEN and SHORT for easy "zero" compensation are available as well.

 

Recommended options

M530-10R 10?

M530-50R 50?

M530-100R 100?

M530-500R 500?

M530-1000R 1000?

OPEN - -

SHORT 0

 

More products MEATEST

HIGH RESISTANCE DECADE FOR CALIBRATION OF MEGOHMMETERS AND INSULATION METERS 5KV MEATEST M191

• Calibration of insulation meters and megaohm meters
• Four decades
• Resistance range 1 MO - 12 GO
• Accuracy from 0.1 % to 1 %
• Maximum working voltage 5 kVdc
• Internal battery / power line adapter supplying
• RS232 bus

 

10KV HIGH RESISTANCE DECADE FOR CALIBRATING MEGOHMMETERS AND INSULATION TESTERS MEATEST M191

• Total resistance range 10.00 k? to 1000.0 G?
• Resistance accuracy 0.1 to 5 %
• Test voltage range 10 000 VDC + 5%
• Test voltage accuracy indication 0.5 % + 10 V
• Test current indication 4 digit from 0.01 pA to 99.99 mADC
• Programmable high resistance decade box
• Short current verification
• Dielectric and absorption parameters simulation: polarization index (PI), dielectric absorption ratio (DAR) and polarization ratio (PR)
• High voltage capacitance in three fix points 10, 50, 100 nF
• HIPOT timer verification

 

PRECISION LABORATORY CALIBRATOR FOR METROLOGY MEATEST M140I

• 35ppm Accuracy
• DC/AC voltage up to 1000 V
• DC/AC current up to 20 A
• TC temperature sensors simulation
• RS232 interface

 

THREE-PHASE POWER & ENERGY CALIBRATOR MEATEST M133CI

• Voltage "phase-neutral" 1 V to 280 Vdc / 300 mA, 1 V to 600 Vac
• AC voltage "phase - phase" 2 V to 1200 V
• DC/AC current 8 mA to 30 A / 5 V
• DC/AC current 90 A in one phase configuration
• Power factor setting -1 to +1
• Floating current outputs to 450 Vpk
• Frequency range 15 Hz to 1 kHz
• Simulated electric power to 54 kVA (2.7 MVA with option 140-50)
• Built-in process multimeter
• GPIB & RS232 interface

 

POWER AND ENERGY CALIBRATOR MEATEST M133

• Voltage "phase-neutral" 1 V to 280 Vdc / 300 mA, 1 V to 600 Vac
• AC voltage "phase - phase" in the 3phase system 2 V to 1200 V
• DC/AC current 8 mA to 30 A / 5 V
• Power factor setting -1 to +1
• Harmonic, interharmonic distortion, modulation
• Frequency range 15 Hz to 1 kHz
• Simulated electric power to 8.4 kVA (420 kVA with option 140-50)
• Built-in process multimeter
• GPIB & RS232 interface

 

PRECISION RESISTANCE DECADE BOX MEATEST M622

• Resistance range 1.000 00 O - 1.200 000 MO
• Accuracy 0.005%
• Resolution from 10 µO
• Range of Pt sensor temperature simulation -200°C - +850°C
• Connection 2, 3, 4-wire
• Remote control RS232, optionally IEEE488
• Internal ACCU/power line adapter

 

AC/DC RESISTANCE LOAD FOR CALIBRATION OF VOLTAGE SOURCES, TRANSFORMERS MEATEST M192

• Resistance range from 15 O to 300 kO
• Maximal load 3kW, maximal voltage 250 Vrms
• Accuracy 0.1 %
• Temperature coefficient < 10 ppm/°C
• Interface RS - 232 (IEEE488 optionally)
• Table version (19" module as option)

 

HIGH PRECISION UNIVERSAL CALIBRATOR MEATEST M142I

• 15ppm Accuracy
• DC/AC voltage up to 1000 V
• DC/AC current up to 30 A
• TC temperature sensors simulation
• RS232 interface

 

RESISTANCE CAPACITANCE INDUCTANCE STANDARD FOR CALIBRATING LCR-METERS

• Resistance Capacitance Inductance standards
• Traceability of electric quantities
• Calibration of meters
• Calibration uncertainty 0.005 %
• Low time constant
• Three/four terminal or four pair terminal connection

 

HIGH PRECISION MULTIFUNCTION CALIBRATOR MEATEST M142

• 15ppm Accuracy
• DC/AC voltage up to 1000 V
• DC/AC current up to 30 A
• Resistance up to 1000 MO, capacitance up to 100 uF
• TC/RTD temperature sensors simulation
• Frequency output up to 20 MHz
• Electric power up to 240 V / 20 A
• Built-in process multimeter
• GPIB & RS232 interface