Resistance Capacitance Inductance Standard for Calibrating LCR-Meters

Code: Meatest RP LP CP


 

Datasheet PDF, 0.13 Mb
 

Description

  • Resistance Capacitance Inductance standards
  • Traceability of electric quantities
  • Calibration of meters
  • Calibration uncertainty 0.005 %
  • Low time constant
  • Three/four terminal or four pair terminal connection

 

Description

Resistance standards MTE series are air standards with high accuarcy and low temperature coefficient. Their are designed for use in cal labs as reference means of resistance quantity saving and for calibration of multimeters and RCL meters. Low time constant involves to use the standards in wide frequency range.

 

According to customer request the standards are equipped with gold plated instrument terminals or with BNC coaxial connectors with possibility of three- and four- terminals or four-pair terminals connection. In high resistance standards terminals with ceramic isolation are used.

 

Recommended options

LP - 100m

LP - 1H

LP - 10H

LP - 100H

LP - 1000H

 

CP - 10p 10 pF 2 0.1 15 £0.001 Ceramic multilayer Silver mica

CP - 100p 1 00 pF 0.1 0.05 15 £0.001 Ceramic multilayer Silver mica

CP - 1n 1 000 pF 0.1 0.02 15 £0.0005 Ceramic multilayer Silver mica

CP - 10n 10 000 pF 0.1 0.02 15 £0.0005 Ceramic multilayer Silver mica

CP - 100n 100 000 pF 0.1 0.02 15 £0.0005 Ceramic multilayer Silver mica

CP - 1u 1 uF 0.1 0.02 50 £0.0005 Polypropylen B

CP - 10u 10 uF 0.2 0.1 50 £0.005 Polypropylen B

CP - 100u 100 uF

 

RP - 0.1 100 mW 0.1 0.05 10 3 Foil resistor B

RP - 1.0 1 W 0.05 0.01 10 3 Foil resistor B

RP - 1.0 1 W 0.05 0.01 1 3 Foil resistor C

RP - 10 10 W 0.01 0.005 1 0.3 Foil resistor C

RP - 100 100 W 0.01 0.005 1 0.3 Foil resistor C

RP - 1k 1 kW 0.01 0.005 1 0.3 Foil resistor C

RP - 10k 10 kW 0.01 0.005 1 50 V *** Foil resistor C

RP - 100k 100 kW 0.01 0.005 1 150 V *** Foil resistor C

RP - 1M 1 MW 0.01 0.005 1 500 V *** Foil resistor B

RP - 10M 10MW 0.05 0.01 100 2 500 V*** Ceramic resistor A

RP - 100M 100 MW 0.5 0.1 100 2 500 V*** Ceramic resistor A

RP - 1G 1 GW 1 0.3 100 5 000 V*** Ceramic resistor A

RP - 10G 10 GW 3 0.5 100 5 000 V*** Ceramic resistor A

 

More products MEATEST

LCR IMPEDANCE CALIBRATOR OF RESISTANCE, CAPACITANCE, INDUCTANCE MEATEST M550

• Resistance standards from 0.1 O to 100 MO
• Capacitance standards from 10 pF to 100 µF
• Simulated inductance standards from 10 µH to 10 H
• Four pair coaxial terminal connection, four terminal connection, two terminal connection
• Calibration data from 20 Hz to 1 MHz
• Interface bus GPIB and RS232 as standard

 

HIGH PRECISION UNIVERSAL CALIBRATOR MEATEST M142I

• 15ppm Accuracy
• DC/AC voltage up to 1000 V
• DC/AC current up to 30 A
• TC temperature sensors simulation
• RS232 interface

 

POWER AND ENERGY CALIBRATOR MEATEST M133I

• Voltage "phase-neutral" 1 V to 280 Vdc / 300 mA, 1 V to 600 Vac
• AC voltage "phase - phase" in the 3phase system 2 V to 1200 V
• DC/AC current 30 mA to 30 A / 5 V, accuracy 310 ppm
• Power factor setting -1 to +1
• Frequency range 15 Hz to 1 kHz
• Simulated electric power up to 8.4 kVA (420 kVA with option 140-50)
• Built-in process multimeter
• GPIB & RS232 interface

 

RESISTANCE CAPACITANCE INDUCTANCE STANDARD FOR CALIBRATING LCR-METERS

• Resistance Capacitance Inductance standards
• Traceability of electric quantities
• Calibration of meters
• Calibration uncertainty 0.005 %
• Low time constant
• Three/four terminal or four pair terminal connection

 

PRECISION LABORATORY CALIBRATOR FOR VOLTAGE, CURRENT, RESISTANCE, CAPACITY, FREQUENCY MEATEST M140

• 35ppm Accuracy
• DC/AC voltage up to 1000 V
• DC/AC current up to 20 A
• Resistance up to 50 MO, capacitance up to 50 µF
• TC/RTD temperature sensors simulation
• Frequency output up to 20 MHz
• Electric power up to 240 V / 10 A
• Built-in process multimeter
• GPIB & RS232 interface

 

THREE-PHASE POWER & ENERGY CALIBRATOR MEATEST M133CI

• Voltage "phase-neutral" 1 V to 280 Vdc / 300 mA, 1 V to 600 Vac
• AC voltage "phase - phase" 2 V to 1200 V
• DC/AC current 8 mA to 30 A / 5 V
• DC/AC current 90 A in one phase configuration
• Power factor setting -1 to +1
• Floating current outputs to 450 Vpk
• Frequency range 15 Hz to 1 kHz
• Simulated electric power to 54 kVA (2.7 MVA with option 140-50)
• Built-in process multimeter
• GPIB & RS232 interface

 

HIGH CURRENT CALIBRATOR FOR CLAMP METERS MEATEST M151

• Current 8 mA … 120 A (AC/DC)
• Frequency 15 Hz … 1 kHz
• Simulated current and transconductance amplifier
• Built-in process multimeter
• Output capability 8 Vpk
• Interface bus GPIB and RS232 as standard
• With current coil it can be used for calibration of clamp meters up to 3000 A

 

AC/DC RESISTANCE LOAD FOR CALIBRATION OF VOLTAGE SOURCES, TRANSFORMERS MEATEST M192

• Resistance range from 15 O to 300 kO
• Maximal load 3kW, maximal voltage 250 Vrms
• Accuracy 0.1 %
• Temperature coefficient < 10 ppm/°C
• Interface RS - 232 (IEEE488 optionally)
• Table version (19" module as option)

 

CAPACITANCE DECADE FOR CALIBRATION LCR-METERS MEATEST M520

• Designed for RCL meters calibration
• Range of capacitance from 100 pF to 12 mF
• Basic accuracy 0.25 %
• Maximal operating voltage 50 V
• Power supplying from internal battery or power line adapter
• Remote control RS-232

 

RTD SIMULATOR OF TEMPERATURE CONTROLLERS PT100, PT200, PT500, PT1000, NI100, NI1000 MEATEST M612

• Calibration of temperature controllers
• Resistance range from 16 O to 10 kO
• Simulation of Pt and Ni sensors
• Accuracy +/- 0.02°C
• Temperature stability < 1 ppm/°C
• Simulation of cable resistances