Resistance Capacitance Inductance Standard for Calibrating LCR-Meters

Code: Meatest RP LP CP


 

Datasheet PDF, 0.13 Mb
 

Description

  • Resistance Capacitance Inductance standards
  • Traceability of electric quantities
  • Calibration of meters
  • Calibration uncertainty 0.005 %
  • Low time constant
  • Three/four terminal or four pair terminal connection

 

Description

Resistance standards MTE series are air standards with high accuarcy and low temperature coefficient. Their are designed for use in cal labs as reference means of resistance quantity saving and for calibration of multimeters and RCL meters. Low time constant involves to use the standards in wide frequency range.

 

According to customer request the standards are equipped with gold plated instrument terminals or with BNC coaxial connectors with possibility of three- and four- terminals or four-pair terminals connection. In high resistance standards terminals with ceramic isolation are used.

 

Recommended options

LP - 100m

LP - 1H

LP - 10H

LP - 100H

LP - 1000H

 

CP - 10p 10 pF 2 0.1 15 £0.001 Ceramic multilayer Silver mica

CP - 100p 1 00 pF 0.1 0.05 15 £0.001 Ceramic multilayer Silver mica

CP - 1n 1 000 pF 0.1 0.02 15 £0.0005 Ceramic multilayer Silver mica

CP - 10n 10 000 pF 0.1 0.02 15 £0.0005 Ceramic multilayer Silver mica

CP - 100n 100 000 pF 0.1 0.02 15 £0.0005 Ceramic multilayer Silver mica

CP - 1u 1 uF 0.1 0.02 50 £0.0005 Polypropylen B

CP - 10u 10 uF 0.2 0.1 50 £0.005 Polypropylen B

CP - 100u 100 uF

 

RP - 0.1 100 mW 0.1 0.05 10 3 Foil resistor B

RP - 1.0 1 W 0.05 0.01 10 3 Foil resistor B

RP - 1.0 1 W 0.05 0.01 1 3 Foil resistor C

RP - 10 10 W 0.01 0.005 1 0.3 Foil resistor C

RP - 100 100 W 0.01 0.005 1 0.3 Foil resistor C

RP - 1k 1 kW 0.01 0.005 1 0.3 Foil resistor C

RP - 10k 10 kW 0.01 0.005 1 50 V *** Foil resistor C

RP - 100k 100 kW 0.01 0.005 1 150 V *** Foil resistor C

RP - 1M 1 MW 0.01 0.005 1 500 V *** Foil resistor B

RP - 10M 10MW 0.05 0.01 100 2 500 V*** Ceramic resistor A

RP - 100M 100 MW 0.5 0.1 100 2 500 V*** Ceramic resistor A

RP - 1G 1 GW 1 0.3 100 5 000 V*** Ceramic resistor A

RP - 10G 10 GW 3 0.5 100 5 000 V*** Ceramic resistor A

 

More products MEATEST

PRECISION PROGRAMMABLE RESISTANCE DECADE BOX MEATEST M630

• Resistance range 1.000 00 O - 1.200 000 MO
• Accuracy 0.003%
• Maximal voltage 200Vpk
• Resolution from 10 µO
• Range of Pt sensor temperature simulation -200°C - +850°C
• Connection 2, 3, 4-wire
• Remote control RS232, optionally USB, IEEE488, Ethernet

 

AC/DC RESISTANCE LOAD FOR CALIBRATION OF VOLTAGE SOURCES, TRANSFORMERS MEATEST M192

• Resistance range from 15 O to 300 kO
• Maximal load 3kW, maximal voltage 250 Vrms
• Accuracy 0.1 %
• Temperature coefficient < 10 ppm/°C
• Interface RS - 232 (IEEE488 optionally)
• Table version (19" module as option)

 

HIGH VOLTAGE AND HIGH RESISTANCE DECADE FOR CALIBRATING MEGOHMMETERS AND INSULATION TESTERS UP TO 10KV MEATEST M191

• Total resistance range 10.00 k? to 1000.0 G?
• Resistance accuracy 0.1 to 5 %
• Test voltage range 10 000 VDC + 5%
• Test voltage accuracy indication 0.5 % + 10 V
• Test current indication 4 digit from 0.01 pA to 99.99 mADC
• Programmable high resistance decade box
• Short current verification
• Dielectric and absorption parameters simulation: polarization index (PI), dielectric absorption ratio (DAR) and polarization ratio (PR)
• High voltage capacitance in three fix points 10, 50, 100 nF
• HIPOT timer verification

 

POWER AND ENERGY CALIBRATOR MEATEST M133I

• Voltage "phase-neutral" 1 V to 280 Vdc / 300 mA, 1 V to 600 Vac
• AC voltage "phase - phase" in the 3phase system 2 V to 1200 V
• DC/AC current 30 mA to 30 A / 5 V, accuracy 310 ppm
• Power factor setting -1 to +1
• Frequency range 15 Hz to 1 kHz
• Simulated electric power up to 8.4 kVA (420 kVA with option 140-50)
• Built-in process multimeter
• GPIB & RS232 interface

 

RF RESISTANCE STANDARD FOR CALIBRATION OF LCR METERS MEATEST M530

• Resistance range 10 O to 1000 O
• Very low frequency dependency
• Applicable frequency range to 100 MHz
• Calibration of wide frequency range LCR meters

 

PRECISION RESISTANCE DECADE BOX MEATEST M622

• Resistance range 1.000 00 O - 1.200 000 MO
• Accuracy 0.005%
• Resolution from 10 µO
• Range of Pt sensor temperature simulation -200°C - +850°C
• Connection 2, 3, 4-wire
• Remote control RS232, optionally IEEE488
• Internal ACCU/power line adapter

 

HIGH RESISTANCE DECADE FOR CALIBRATION OF MEGOHMMETERS AND INSULATION METERS 5KV MEATEST M191

• Calibration of insulation meters and megaohm meters
• Four decades
• Resistance range 1 MO - 12 GO
• Accuracy from 0.1 % to 1 %
• Maximum working voltage 5 kVdc
• Internal battery / power line adapter supplying
• RS232 bus

 

RTD SIMULATOR OF TEMPERATURE CONTROLLERS PT100, PT200, PT500, PT1000, NI100, NI1000 MEATEST M612

• Calibration of temperature controllers
• Resistance range from 16 O to 10 kO
• Simulation of Pt and Ni sensors
• Accuracy +/- 0.02°C
• Temperature stability < 1 ppm/°C
• Simulation of cable resistances
• Interface RS 232 (IEEE488 optionally)

 

LCR IMPEDANCE CALIBRATOR OF RESISTANCE, CAPACITANCE, INDUCTANCE MEATEST M550

• Resistance standards from 0.1 O to 100 MO
• Capacitance standards from 10 pF to 100 µF
• Simulated inductance standards from 10 µH to 10 H
• Four pair coaxial terminal connection, four terminal connection, two terminal connection
• Calibration data from 20 Hz to 1 MHz
• Interface bus GPIB and RS232 as standard

 

RESISTANCE CAPACITANCE INDUCTANCE STANDARD FOR CALIBRATING LCR-METERS

• Resistance Capacitance Inductance standards
• Traceability of electric quantities
• Calibration of meters
• Calibration uncertainty 0.005 %
• Low time constant
• Three/four terminal or four pair terminal connection