Description

  • Voltage "phase-neutral" 1 V to 280 Vdc / 300 mA, 1 V to 600 Vac
  • AC voltage "phase - phase" 2 V to 1200 V
  • DC/AC current 8 mA to 30 A / 5 V
  • DC/AC current 90 A in one phase configuration
  • Power factor setting -1 to +1
  • Floating current outputs to 450 Vpk
  • Harmonic, interharmonic distortion, modulation
  • Frequency range 15 Hz to 1 kHz
  • Simulated electric power to 54 kVA (2.7 MVA with option 140-50)
  • Built-in process multimeter
  • GPIB & RS232 interface

 

Description

Model M133C is compact one-housing three phase electric power/energy calibrator. It can supply unit under test with one phase accurate AC voltage and current with calibrated phase shift or DC voltage and current. Output voltage can be set in six ranges up to 600 V and output current in six ranges up to 30 A. Simulated electric power can be set independently in each phase. Frequency can be set in range from 15 Hz to 1 kHz with resolution 0.001 Hz to 0.01 Hz. Calibrator is equipped with 5 1/2 digital DC meter with DC ranges 20 mA or 10 V for direct calibrating of various types of power transducers.

M133C calibrator offers two types of defined distortion of main sinusoidal output signal. The first distortion is based on adding defined amount of harmonic or interharmonic spectral components up to 5 kHz. The second type of distortion is based on amplitude modulation of output sinusoidal signal by sin or squarewave modulation signal in frequency range from 0.001 Hz to 50 Hz. Maximum depth of modulation is 30 %.

Using supplied cable adapter the current outputs can be joined together offering one phase current range to 90 A AC/DC.

M133 control panel facilitates setting of power energy calibrators series M133. It is possible to set all three phase channels and also waveforms of individual voltage (current) outputs. Setting of harmonic / interharmonic components, modulation and Dip/Swells is displayed in simple chart.

 

 

Standard accessories

  • Power supply cable 1 pc
  • Operation manual, CD 1 pc
  • Option 10 Test cable banana-banana 1000V - 32 A, black 3 pcs Length 1m
  • Option 11 Test cable banana-banana 1000V - 32 A, red 3 pcs Length 1m
  • Option 12 Test cable banana-banana 1000V - 32 A, blue 3 pcs Length 1m
  • Option 13 Test cable banana-banana 1000V - 32 A, yellow 3 pcs Length 1m
  • Spare fuse 1 pc
  • RS 232 cable 1 pc Length 1.5m
  • M133C-01 High Current Adapter 1 pc
 

Recommended options

  • Option 140-50 Current coil 25/50 turns For clamp ammeters
  • Option 10 Test cable banana-banana 1000V - 32 A, black Length 1m
  • Option 11 Test cable banana-banana 1000V - 32 A, red Length 1m
  • Option 12 Test cable banana-banana 1000V - 32 A, blue Length 1m
  • Option 13 Test cable banana-banana 1000V - 32 A, yellow Length 1m
  • GPIB cable GPIB interface cable Length 1 m
  • RS-232 cable RS-232 interface cable Length 1.5 m
  • POWER Application SW. Transducers calibration.
 

More products MEATEST

HIGH CURRENT CALIBRATOR FOR CLAMP METERS MEATEST M151

• Current 8 mA … 120 A (AC/DC)
• Frequency 15 Hz … 1 kHz
• Simulated current and transconductance amplifier
• Built-in process multimeter
• Output capability 8 Vpk
• Interface bus GPIB and RS232 as standard
• With current coil it can be used for calibration of clamp meters up to 3000 A

 

POWER AND ENERGY CALIBRATOR MEATEST M133I

• Voltage "phase-neutral" 1 V to 280 Vdc / 300 mA, 1 V to 600 Vac
• AC voltage "phase - phase" in the 3phase system 2 V to 1200 V
• DC/AC current 30 mA to 30 A / 5 V, accuracy 310 ppm
• Power factor setting -1 to +1
• Frequency range 15 Hz to 1 kHz
• Simulated electric power up to 8.4 kVA (420 kVA with option 140-50)
• Built-in process multimeter
• GPIB & RS232 interface

 

HIGH VOLTAGE AND HIGH RESISTANCE DECADE FOR CALIBRATING MEGOHMMETERS AND INSULATION TESTERS UP TO 10KV MEATEST M191

• Total resistance range 10.00 k? to 1000.0 G?
• Resistance accuracy 0.1 to 5 %
• Test voltage range 10 000 VDC + 5%
• Test voltage accuracy indication 0.5 % + 10 V
• Test current indication 4 digit from 0.01 pA to 99.99 mADC
• Programmable high resistance decade box
• Short current verification
• Dielectric and absorption parameters simulation: polarization index (PI), dielectric absorption ratio (DAR) and polarization ratio (PR)
• High voltage capacitance in three fix points 10, 50, 100 nF
• HIPOT timer verification

 

AC/DC RESISTANCE LOAD FOR CALIBRATION OF VOLTAGE SOURCES, TRANSFORMERS MEATEST M192

• Resistance range from 15 O to 300 kO
• Maximal load 3kW, maximal voltage 250 Vrms
• Accuracy 0.1 %
• Temperature coefficient < 10 ppm/°C
• Interface RS - 232 (IEEE488 optionally)
• Table version (19" module as option)

 

HIGH RESISTANCE DECADE FOR CALIBRATION OF MEGOHMMETERS AND INSULATION METERS 5KV MEATEST M191

• Calibration of insulation meters and megaohm meters
• Four decades
• Resistance range 1 MO - 12 GO
• Accuracy from 0.1 % to 1 %
• Maximum working voltage 5 kVdc
• Internal battery / power line adapter supplying
• RS232 bus

 

HIGH PRECISION UNIVERSAL CALIBRATOR MEATEST M142I

• 15ppm Accuracy
• DC/AC voltage up to 1000 V
• DC/AC current up to 30 A
• TC temperature sensors simulation
• RS232 interface

 

PRECISION LABORATORY CALIBRATOR FOR METROLOGY MEATEST M140I

• 35ppm Accuracy
• DC/AC voltage up to 1000 V
• DC/AC current up to 20 A
• TC temperature sensors simulation
• RS232 interface

 

LCR IMPEDANCE CALIBRATOR OF RESISTANCE, CAPACITANCE, INDUCTANCE MEATEST M550

• Resistance standards from 0.1 O to 100 MO
• Capacitance standards from 10 pF to 100 µF
• Simulated inductance standards from 10 µH to 10 H
• Four pair coaxial terminal connection, four terminal connection, two terminal connection
• Calibration data from 20 Hz to 1 MHz
• Interface bus GPIB and RS232 as standard

 

RESISTANCE CAPACITANCE INDUCTANCE STANDARD FOR CALIBRATING LCR-METERS

• Resistance Capacitance Inductance standards
• Traceability of electric quantities
• Calibration of meters
• Calibration uncertainty 0.005 %
• Low time constant
• Three/four terminal or four pair terminal connection

 

RESISTIVE DECADE BOX MEATEST M602

• Resistance range from 0.1 O to 10 MO with accuracy 0.02 %
• Temperature coefficient < 25 ppm/°C
• Max. load 2 W (120 V and 0.6 A)
• RTD (Pt, Ni) simulation with accuracy 0.2 °C
• Power supplying from power line adaptor or from internal battery
• Interface RS232 (IEEE488 optionally)
• Table version (19" module as option)