High Resistance Decade for calibration of Megohmmeters and Insulation Meters 5kV Meatest M191

Code: Meatest M109R


 

Datasheet PDF, 0.2 Mb

Description

  • Calibration of insulation meters and megaohm meters
  • Four decades
  • Resistance range 1 MO - 12 GO
  • Accuracy from 0.1 % to 1 %
  • Maximum working voltage 5 kVdc
  • Internal battery / power line adapter supplying
  • RS232 bus

 

Description

High resistance decade box is aimed for calibrating of insulation meters and megaohm-meters. It is suitable for calibration laboratories and service centres, where can be used also for testing or setting of high resistance meters. High voltage relays with extremely high insulation resistance are used for switching of resistance components.

 

M109R is equipped with indication of input terminal overload. Instrument is supplied from internal accumulator or power line adapter. Control is possible manually or remotely via serial interface RS232.

 

Decade box can be ordered as 19" module for easy assembling into a 19" rack. Module height is 3HE.

 

Standard accessories

  • High resistance decade M - 109R
  • Power line adapter
  • Cable RS-232
  • Software
  • User’s manual
 

More products MEATEST

LCR IMPEDANCE CALIBRATOR OF RESISTANCE, CAPACITANCE, INDUCTANCE MEATEST M550

• Resistance standards from 0.1 O to 100 MO
• Capacitance standards from 10 pF to 100 µF
• Simulated inductance standards from 10 µH to 10 H
• Four pair coaxial terminal connection, four terminal connection, two terminal connection
• Calibration data from 20 Hz to 1 MHz
• Interface bus GPIB and RS232 as standard

 

PRECISION LABORATORY CALIBRATOR FOR VOLTAGE, CURRENT, RESISTANCE, CAPACITY, FREQUENCY MEATEST M140

• 35ppm Accuracy
• DC/AC voltage up to 1000 V
• DC/AC current up to 20 A
• Resistance up to 50 MO, capacitance up to 50 µF
• TC/RTD temperature sensors simulation
• Frequency output up to 20 MHz
• Electric power up to 240 V / 10 A
• Built-in process multimeter
• GPIB & RS232 interface

 

HIGH RESISTANCE DECADE FOR CALIBRATION OF MEGOHMMETERS AND INSULATION METERS 5KV MEATEST M191

• Calibration of insulation meters and megaohm meters
• Four decades
• Resistance range 1 MO - 12 GO
• Accuracy from 0.1 % to 1 %
• Maximum working voltage 5 kVdc
• Internal battery / power line adapter supplying
• RS232 bus

 

PRECISION LABORATORY CALIBRATOR FOR METROLOGY MEATEST M140I

• 35ppm Accuracy
• DC/AC voltage up to 1000 V
• DC/AC current up to 20 A
• TC temperature sensors simulation
• RS232 interface

 

RF RESISTANCE STANDARD FOR CALIBRATION OF LCR METERS MEATEST M530

• Resistance range 10 O to 1000 O
• Very low frequency dependency
• Applicable frequency range to 100 MHz
• Calibration of wide frequency range LCR meters

 

HIGH PRECISION MULTIFUNCTION CALIBRATOR MEATEST M142

• 15ppm Accuracy
• DC/AC voltage up to 1000 V
• DC/AC current up to 30 A
• Resistance up to 1000 MO, capacitance up to 100 uF
• TC/RTD temperature sensors simulation
• Frequency output up to 20 MHz
• Electric power up to 240 V / 20 A
• Built-in process multimeter
• GPIB & RS232 interface

 

RESISTIVE DECADE BOX MEATEST M602

• Resistance range from 0.1 O to 10 MO with accuracy 0.02 %
• Temperature coefficient < 25 ppm/°C
• Max. load 2 W (120 V and 0.6 A)
• RTD (Pt, Ni) simulation with accuracy 0.2 °C
• Power supplying from power line adaptor or from internal battery
• Interface RS232 (IEEE488 optionally)
• Table version (19" module as option)

 

PRECISION PROGRAMMABLE RESISTANCE DECADE BOX MEATEST M630

• Resistance range 1.000 00 O - 1.200 000 MO
• Accuracy 0.003%
• Maximal voltage 200Vpk
• Resolution from 10 µO
• Range of Pt sensor temperature simulation -200°C - +850°C
• Connection 2, 3, 4-wire
• Remote control RS232, optionally USB, IEEE488, Ethernet

 

RTD SIMULATOR OF TEMPERATURE CONTROLLERS PT100, PT200, PT500, PT1000, NI100, NI1000 MEATEST M612

• Calibration of temperature controllers
• Resistance range from 16 O to 10 kO
• Simulation of Pt and Ni sensors
• Accuracy +/- 0.02°C
• Temperature stability < 1 ppm/°C
• Simulation of cable resistances
• Interface RS 232 (IEEE488 optionally)

 

LCR IMPEDANCE CALIBRATOR OF RESISTANCE, CAPACITANCE, INDUCTANCE MEATEST M550

• Resistance standards from 0.1 O to 100 MO
• Capacitance standards from 10 pF to 100 µF
• Simulated inductance standards from 10 µH to 10 H
• Four pair coaxial terminal connection, four terminal connection, two terminal connection
• Calibration data from 20 Hz to 1 MHz
• Interface bus GPIB and RS232 as standard