RTD Simulator of Temperature Controllers Pt100, Pt200, Pt500, Pt1000, Ni100, Ni1000 Meatest M612

Code: Meatest M612


 

Datasheet PDF, 0.19 Mb

Description

  • Calibration of temperature controllers
  • Resistance range from 16 O to 10 kO
  • Simulation of Pt and Ni sensors
  • Accuracy +/- 0.02°C
  • Temperature stability < 1 ppm/°C
  • Simulation of cable resistances
  • Interface RS 232 (IEEE488 optionally)

 

Description

RTD simulator is aimed for calibrating of temperature controllers. It is suitable for calibration laboratories and service centers, where it can be used also as computer controlled resistance decade.
The instrument is supplied from accumulator or via power line adapter. The Control is possible manually or remotely via serial interface RS232 (IEEE488). RTD simulator can be ordered as 19" module for easy assembling into a 19" rack. Module height is 3HE.

 

Standard accessories

  • Precision RTD Simulator M612
  • Power line adapter
  • Cable RS 232 (for RS232 basic version only)
  • Application software
  • User’s manual
 

Recommended options

Ordering information - options

Bus M612-V1xxx - RS232

M612-V2xxx - IEEE488

Additional functions M612-Vx0xx - none

M612-Vx1xx - Short / Open

Housing M612-Vxx0x - table version

M612-Vxx1x - module 19", 3HE

 

More products MEATEST

RESISTANCE CAPACITANCE INDUCTANCE STANDARD FOR CALIBRATING LCR-METERS

• Resistance Capacitance Inductance standards
• Traceability of electric quantities
• Calibration of meters
• Calibration uncertainty 0.005 %
• Low time constant
• Three/four terminal or four pair terminal connection

 

HIGH CURRENT CALIBRATOR FOR CLAMP METERS MEATEST M151

• Current 8 mA … 120 A (AC/DC)
• Frequency 15 Hz … 1 kHz
• Simulated current and transconductance amplifier
• Built-in process multimeter
• Output capability 8 Vpk
• Interface bus GPIB and RS232 as standard
• With current coil it can be used for calibration of clamp meters up to 3000 A

 

LCR IMPEDANCE CALIBRATOR OF RESISTANCE, CAPACITANCE, INDUCTANCE MEATEST M550

• Resistance standards from 0.1 O to 100 MO
• Capacitance standards from 10 pF to 100 µF
• Simulated inductance standards from 10 µH to 10 H
• Four pair coaxial terminal connection, four terminal connection, two terminal connection
• Calibration data from 20 Hz to 1 MHz
• Interface bus GPIB and RS232 as standard

 

POWER AND ENERGY CALIBRATOR MEATEST M133

• Voltage "phase-neutral" 1 V to 280 Vdc / 300 mA, 1 V to 600 Vac
• AC voltage "phase - phase" in the 3phase system 2 V to 1200 V
• DC/AC current 8 mA to 30 A / 5 V
• Power factor setting -1 to +1
• Harmonic, interharmonic distortion, modulation
• Frequency range 15 Hz to 1 kHz
• Simulated electric power to 8.4 kVA (420 kVA with option 140-50)
• Built-in process multimeter
• GPIB & RS232 interface

 

THREE-PHASE POWER & ENERGY CALIBRATOR MEATEST M133C

• Voltage "phase-neutral" 1 V to 280 Vdc / 300 mA, 1 V to 600 Vac
• AC voltage "phase - phase" 2 V to 1200 V
• DC/AC current 8 mA to 30 A / 5 V
• DC/AC current 90 A in one phase configuration
• Power factor setting -1 to +1
• Floating current outputs to 450 Vpk
• Harmonic, interharmonic distortion, modulation
• Frequency range 15 Hz to 1 kHz
• Simulated electric power to 54 kVA (2.7 MVA with option 140-50)
• Built-in process multimeter
• GPIB & RS232 interface

 

HIGH VOLTAGE AND HIGH RESISTANCE DECADE FOR CALIBRATING MEGOHMMETERS AND INSULATION TESTERS UP TO 10KV MEATEST M191

• Total resistance range 10.00 k? to 1000.0 G?
• Resistance accuracy 0.1 to 5 %
• Test voltage range 10 000 VDC + 5%
• Test voltage accuracy indication 0.5 % + 10 V
• Test current indication 4 digit from 0.01 pA to 99.99 mADC
• Programmable high resistance decade box
• Short current verification
• Dielectric and absorption parameters simulation: polarization index (PI), dielectric absorption ratio (DAR) and polarization ratio (PR)
• High voltage capacitance in three fix points 10, 50, 100 nF
• HIPOT timer verification

 

HIGH RESISTANCE DECADE FOR CALIBRATION OF MEGOHMMETERS AND INSULATION METERS 5KV MEATEST M191

• Calibration of insulation meters and megaohm meters
• Four decades
• Resistance range 1 MO - 12 GO
• Accuracy from 0.1 % to 1 %
• Maximum working voltage 5 kVdc
• Internal battery / power line adapter supplying
• RS232 bus

 

LCR IMPEDANCE CALIBRATOR OF RESISTANCE, CAPACITANCE, INDUCTANCE MEATEST M550

• Resistance standards from 0.1 O to 100 MO
• Capacitance standards from 10 pF to 100 µF
• Simulated inductance standards from 10 µH to 10 H
• Four pair coaxial terminal connection, four terminal connection, two terminal connection
• Calibration data from 20 Hz to 1 MHz
• Interface bus GPIB and RS232 as standard

 

RESISTIVE DECADE BOX MEATEST M602

• Resistance range from 0.1 O to 10 MO with accuracy 0.02 %
• Temperature coefficient < 25 ppm/°C
• Max. load 2 W (120 V and 0.6 A)
• RTD (Pt, Ni) simulation with accuracy 0.2 °C
• Power supplying from power line adaptor or from internal battery
• Interface RS232 (IEEE488 optionally)
• Table version (19" module as option)

 

PRECISION LABORATORY CALIBRATOR FOR METROLOGY MEATEST M140I

• 35ppm Accuracy
• DC/AC voltage up to 1000 V
• DC/AC current up to 20 A
• TC temperature sensors simulation
• RS232 interface