Code: Meatest M140i
Description
Description
Multifunction calibrator M140i is calibrator, determined mainly as standard of electric quantities in calibration laboratories. It can be used for calibration of electrical quantity meters from the field of voltage and current. Calibrator is simpler and low cost version of model M140.
Basic parameters
Basic function of the calibrator is generating of the calibrated DC/AC voltage in the range from 0 V to 1000 V and DC/AC current in the range from 0 A to 20 A . Using a 50-turn coil the current range can be extended from 50 µA to 1000 A. The best accuracy of the calibrator on DC voltage ranges is 0.0035 %, on AC voltage ranges 0.03 %, on DC current ranges 0.013 % and on AC current ranges 0.055 %. Maximum frequency range is from 20 Hz to 100 kHz for harmonic output waveform. consumption. For calibrations of the thermometers and temperature regulators, the function of simulation of temperature sensors is determined. Calibrator is able to simulate all TC sensors of the R, S, B, J, T, E, K and N types as well. Compensation of the TC cold junction is made by entering value from the keyboard.
User comfort
M140 Calibrator is equipped with a number of other functions which make its use easier. Among them belong possibility to set relative deviations from the actual value of the selected output signal, displaying of the output signal uncertainty, internal calibration procedure and others. Concept of the calibrator's control and indication uses a large area luminescence display on which all necessary information is concentrated. The control is perform by selection from the menu. Moreover, frequently used functions have firmly assigned keys with direct control. As standard calibrator is equipped with RS-232 serial port making it possible to be controlled by personal computer.
The calibrator can be included into MEATESTīs WinQbase software calibration systems.
Standard accessories
Recommended options
More products MEATEST
|
AC/DC RESISTANCE LOAD FOR CALIBRATION OF VOLTAGE SOURCES, TRANSFORMERS MEATEST M192
• Resistance range from 15 O to 300 kO |
|
LCR IMPEDANCE CALIBRATOR OF RESISTANCE, CAPACITANCE, INDUCTANCE MEATEST M550
• Resistance standards from 0.1 O to 100 MO |
|
LCR IMPEDANCE CALIBRATOR OF RESISTANCE, CAPACITANCE, INDUCTANCE MEATEST M550
• Resistance standards from 0.1 O to 100 MO |
|
POWER AND ENERGY CALIBRATOR MEATEST M133
• Voltage "phase-neutral" 1 V to 280 Vdc / 300 mA, 1 V to 600 Vac |
|
PRECISION LABORATORY CALIBRATOR FOR VOLTAGE, CURRENT, RESISTANCE, CAPACITY, FREQUENCY MEATEST M140
• 35ppm Accuracy |
|
HIGH PRECISION UNIVERSAL CALIBRATOR MEATEST M142I
• 15ppm Accuracy |
|
CAPACITANCE DECADE FOR CALIBRATION LCR-METERS MEATEST M520
• Designed for RCL meters calibration |
|
THREE-PHASE POWER & ENERGY CALIBRATOR MEATEST M133C
• Voltage "phase-neutral" 1 V to 280 Vdc / 300 mA, 1 V to 600 Vac |
|
RF RESISTANCE STANDARD FOR CALIBRATION OF LCR METERS MEATEST M530
• Resistance range 10 O to 1000 O |
|
PRECISION LABORATORY CALIBRATOR FOR METROLOGY MEATEST M140I
• 35ppm Accuracy |