Insulation Tester for Single/Three-Phase Electrical Installations 1000V HT Italia GSC57/ GSC53N/ ZG47
OBSOLET PRODUCT ( * OUT OF USE )

Code: HT Italia GSC57/ GSC53N/ ZG47


 

Datasheet PDF, 0.46 Mb

Description

  • Continuity on protective conductors PE with 200mA
  • Continuity on protective conductors PE with 10A
  • Insulation resistance up to 1000V DC
  • Tripping time and current of RCDs (type A, AC, general and selective)
  • Line and Loop impedance with calculation of the prospective short circuit current
  • Loop/Line impedance with high resolution (0.1mOhm) (with IMP57 optional accessory)
  • Global Earth Resistance without RCDs tripping
  • Earth resistance with 3-wire and 2-wire methods
  • Ground resistivity with 4-wire method
  • Contact voltage
  • Phase rotation
  • TRMS measure and recording of any parameter of Single and Three phase plants
  • Harmonic analysis of voltage and current up to the 49th order
  • Voltage anomalies (sags, swells) with a 10ms resolution
  • Measurement and recording to leakage current (with HT96U optional accessory)
  • Measurement and recording of air temperature  (°C/°F), humidity (HR%)
  • Measurement and recording Illuminations (Lux)
  • Save results inside memory
  • Interface for PC comunication
 

Standard accessories

  • C2033X: cable 3-wire with Shuko plug
  • A0050: power adaptor 230V/50 Hz
  • KITGSC5: kit of 4 cables 2m , 4 alligators e 2 test leads
  • KITTERRNE: bag with 4 cable banana/banana + 4 metal rods
  • Hz
  • TOPVIEW2006: Windows PC software + optical/USB cable C2006
  • BORSA2051: carrying bag
  • Calibration certificate ISO9000
  • User manual
 
GSC57 also include C5700: power cable for 10A continuity test
GSC53N/ ZG47 also include HTFLEX33D: flexible clamp AC 3000A, diameter 174mm, 3 pcs
 

Recommended options

  • C7000/05: 2 cables, 5m length, for 10A test
  • C7000/10: 2 cables, 10m lengt,  for 10A test
  • HT52/05: transducer for air temperature/humidity
  • HT53/05: transducer for lux measurements
  • HTFLEX3003: kit of 3 flexible clamps 300-3000A/1V AC, max diameter 174mm
  • HTFLEX1000: kit of 3 flexible clamp 1000A/1V AC, max diameter 154mm
  • HT96U: clamp 1-100-1000A/1V AC, max diameter 54mm
  • HT97U: clamp 10-100-1000A/1V AC, max diameter 54mm
  • HT903: accessory 3x1-5A/1V for connection to external CT's
  • IMP57: accessory ZLoop/Line at high resolution
 

More products HT ITALIA

DIGITAL CURRENT CLAMP METERS HT ITALIA

• DC/AC/AC+DC TRMS current
• DC/AC/Ac+DC TRMS Voltage
• Peak of AC current and AC voltage

 

INFRARED NON CONTACT THERMOMETER HT ITALIA

• Infrared temperature measurement from -50°C to 1000 °C
• Emissivity regulation
• Distance / Spot ratio of 50:1
• Laser pointer activation

 

ENVIRONEMENTAL MULTIFUNCTION TESTERS HT ITALIA

• Air temperature (°C/°F)
• Air relative humidity (%RH)
• Air speed (m/S)
• Air volume (m3/s)
• Capacity measurements (kW)
• Temperature dew point measurement

 

HT2055 STEP AND CONTACT METER UP TO 50A

• TRMS
• Measuring range 200Ω
• Earth resistance by 2- and 3-wire method
• Ground resistivity by 4-wire method
• Compensation of disturbance voltages
• Compensation of test cables
• Measurement of step/contact voltage

 

FULLTEST3 MULTIFUNCTION TESTER FOR SAFETY OF MACHINERY IEC/EN60204-1 AND LOW VOLTAGE SWITCHGEARS AND CONTROLGEARS IEC/EN61439-1-2

• IEC/EN60204-1 and IEC/EN61439-1-2 Measuments
• Continuity of protective circuit with 200mA
• Continuity of protective circuit with I>10A, V<12V
• Continuity of protective circuit with I>25A, V<12V
• Insulation with test voltages 100, 250, 500, 1000VDC
• Dielectric strength with voltage programmable from 250V to 5100VAC

 

INSULATION CONTINUITY MEGOHMMETER AND DIGITAL MULTIMETER HT ITALIA M72

• Insulation Resistance with 250, 500VDC
• Measurement range up to 1GOhm
• Automatic discharging object after test
• Continuity test of protective conductors with 200mA
• DC Voltage
• AC TRMS Voltage

 

EARTH GROUNDING RESISTANCE MULTIMETER HT ITALIA M71

• 3-wire Earth Resistance
• 2-wire Earth Resistance
• Measurement range up to 50kOhm
• Calibration of test cables
• Automatic regulation of noise voltage disturbances

 

EARTH RESISTANCE AND LOOP IMPEDANCE RCD TESTER HT ITALIA SPEED 418

• Tripping time on RCD type A, AC General and Selective with currents 10, 30,100, 300, 500mA
• Tripping time on RCD type AC General with currents 30, 30x5, 100, 300mA
• Tripping current on RCD type A, AC General and Selective Global earth resistance without RCD tripping
• Line/Loop impedance, also with high-resolution (0.1m )( with optional accessory IMP57)
• Optical/USB interface for connection to PC

 

HANDHELD DIGITAL SOUNDMETER WITH CALIBRATOR HT ITALIA HT154

• Measure of Sound Level Pressure (SPL)
• 0.1dB resolution
• Selection manual of range
• MAX/MIN display
• Frequency Weighting A and C
• Integration FAST/SLOW

 

STEP AND CONTACT VOLTAGE METER WITH TEST CURRENT UP TO 50A HT ITALIA HT2055

• Step/Contact voltage with separated units
• Synchronization between units
• Test current up to 50A
• Earth resistance measurement
• Ground resistivity measurement
• Internal memory for saving results
• USB and RS-232 ports for communication between units and PC