Insulation Tester for Single/Three-Phase Electrical Installations 1000V HT Italia GSC57/ GSC53N/ ZG47
OBSOLET PRODUCT ( * OUT OF USE )

Code: HT Italia GSC57/ GSC53N/ ZG47


 

Datasheet PDF, 0.46 Mb

Description

  • Continuity on protective conductors PE with 200mA
  • Continuity on protective conductors PE with 10A
  • Insulation resistance up to 1000V DC
  • Tripping time and current of RCDs (type A, AC, general and selective)
  • Line and Loop impedance with calculation of the prospective short circuit current
  • Loop/Line impedance with high resolution (0.1mOhm) (with IMP57 optional accessory)
  • Global Earth Resistance without RCDs tripping
  • Earth resistance with 3-wire and 2-wire methods
  • Ground resistivity with 4-wire method
  • Contact voltage
  • Phase rotation
  • TRMS measure and recording of any parameter of Single and Three phase plants
  • Harmonic analysis of voltage and current up to the 49th order
  • Voltage anomalies (sags, swells) with a 10ms resolution
  • Measurement and recording to leakage current (with HT96U optional accessory)
  • Measurement and recording of air temperature  (°C/°F), humidity (HR%)
  • Measurement and recording Illuminations (Lux)
  • Save results inside memory
  • Interface for PC comunication
 

Standard accessories

  • C2033X: cable 3-wire with Shuko plug
  • A0050: power adaptor 230V/50 Hz
  • KITGSC5: kit of 4 cables 2m , 4 alligators e 2 test leads
  • KITTERRNE: bag with 4 cable banana/banana + 4 metal rods
  • Hz
  • TOPVIEW2006: Windows PC software + optical/USB cable C2006
  • BORSA2051: carrying bag
  • Calibration certificate ISO9000
  • User manual
 
GSC57 also include C5700: power cable for 10A continuity test
GSC53N/ ZG47 also include HTFLEX33D: flexible clamp AC 3000A, diameter 174mm, 3 pcs
 

Recommended options

  • C7000/05: 2 cables, 5m length, for 10A test
  • C7000/10: 2 cables, 10m lengt,  for 10A test
  • HT52/05: transducer for air temperature/humidity
  • HT53/05: transducer for lux measurements
  • HTFLEX3003: kit of 3 flexible clamps 300-3000A/1V AC, max diameter 174mm
  • HTFLEX1000: kit of 3 flexible clamp 1000A/1V AC, max diameter 154mm
  • HT96U: clamp 1-100-1000A/1V AC, max diameter 54mm
  • HT97U: clamp 10-100-1000A/1V AC, max diameter 54mm
  • HT903: accessory 3x1-5A/1V for connection to external CT's
  • IMP57: accessory ZLoop/Line at high resolution
 

More products HT ITALIA

INSULATION CONTINUITY MEGOHMMETER AND DIGITAL MULTIMETER HT ITALIA M72

• Insulation Resistance with 250, 500VDC
• Measurement range up to 1GOhm
• Automatic discharging object after test
• Continuity test of protective conductors with 200mA
• DC Voltage
• AC TRMS Voltage

 

SAFETY TESTER FOR PHOTOVOLTAIC SYSTEMS HT PVCHECK

• Safety test of PV installation
• Continuity test on protective conductors with 200mA
• Insulation test with test voltage of 250, 500, 1000VDC
• DC voltage
• DC current
• DC Power
• Solar irradiation [W/m2] with reference cell

 

HT2055 STEP AND CONTACT METER UP TO 50A

• TRMS
• Measuring range 200Ω
• Earth resistance by 2- and 3-wire method
• Ground resistivity by 4-wire method
• Compensation of disturbance voltages
• Compensation of test cables
• Measurement of step/contact voltage

 

THREE-PHASE POWER QUALITY ANALYZER HT PQA820

• 3 system types: Single-phase, three-phase 3-wire, three-phase 4-wire.
•  Configurable directly from Smartphone or Tablet.
•  Fast trips and detailed zoom of all sizes.
•  Real Time.
•  Energy consumption logger.
•  383 parameters can be displayed simultaneously.
•  Technology and absolute simplicity.
•  Harmonics Jump function.

 

HANDHELD DIGITAL MEGOHMMETER INSULATION & CONTINUITY 4 GOHM 1000V HT ITALIA M70

• Insulation with test voltage 250, 500, 1000VDC
• Up to 4Gohm measurement range
• Automatic discharge of device under test
• LOCK feature for continuous measurements
• Programmable timer up to 60s
• Continuity of earth conductors with test current of 200mA
• A/DC voltage up to 600V
• Resistance and continuity test with buzzer

 

HT PQA924 CLASS S POWER QUALITY AND ENERGY ANALYZER

• AC voltage in single-phase and three-phase systems
• AC current in single-phase and three-phase systems
• Cosphi, Power Factor, K-Factor
• Voltage unbalance
• Flicker
• Active, Reactive, and Apparent power/energy
• Voltage and current harmonic amplitude and phase up to the 63rd order with THD% calculation

 

PVCHECKS-ONE COMMISSIONING TESTER FOR PV SYSTEM UP TO 1000V / 30A

• Continuity of protective circuit with 200mA
• Polarity
• Open circuit voltage Voc of PV modules and strings 1000V
• Short circuit current Isc on PV modules and strings 30A
• PV string/field insulation with test voltage 250, 500, 1000VDC
• Measurement of polarization index P.I.
• Dielectric absorption ratio D.A.R
• GFL function to locate the fault position in the string
• Measurement category CAT III 1000V
• OPT function for insulation testing on PV strings in the presence of MLPE

 

AUDIO ANALYZER CLASS 1 HT ITALIA HT155/ HT157

• Measuring range 25-140dB
• "Peak", "Fast", "Slow" and "Impulse" integrations
• "A", "C" and "Z (linear)" frequency weighting
• "Peak+" and "Peak-" measurement in C weighting
• Spectral analysis with octave and 1/3 octave digital filter (HT157)
• Class 1 portable calibrator
• Mini-USB output for connection to PC

 

MACROEVTEST MULTIFUNCTION TESTER WITH POWER ANALYSIS AND ELECTRIC VEHICLE CHARGING STATIONS EVSE

• Multifunction instrument for electrical installation safety testing
• power quality analysis
• EVSE safety testing
• MACROEVTEST is the new HT instrument to perform verification and control of electric car charging stations (EVSE) safety according to IEC / EN 61851-1 and IEC / EN60364-7-722 standards

 

DIGITAL PORTABLE MULTIMETERS HT ITALIA

• DC Voltage
• AC TRMS Voltage
• DC Current
• AC TRMS Current