Insulation Tester for Single/Three-Phase Electrical Installations 1000V HT Italia GSC57/ GSC53N/ ZG47
OBSOLET PRODUCT ( * OUT OF USE )

Code: HT Italia GSC57/ GSC53N/ ZG47


 

Datasheet PDF, 0.46 Mb

Description

  • Continuity on protective conductors PE with 200mA
  • Continuity on protective conductors PE with 10A
  • Insulation resistance up to 1000V DC
  • Tripping time and current of RCDs (type A, AC, general and selective)
  • Line and Loop impedance with calculation of the prospective short circuit current
  • Loop/Line impedance with high resolution (0.1mOhm) (with IMP57 optional accessory)
  • Global Earth Resistance without RCDs tripping
  • Earth resistance with 3-wire and 2-wire methods
  • Ground resistivity with 4-wire method
  • Contact voltage
  • Phase rotation
  • TRMS measure and recording of any parameter of Single and Three phase plants
  • Harmonic analysis of voltage and current up to the 49th order
  • Voltage anomalies (sags, swells) with a 10ms resolution
  • Measurement and recording to leakage current (with HT96U optional accessory)
  • Measurement and recording of air temperature  (°C/°F), humidity (HR%)
  • Measurement and recording Illuminations (Lux)
  • Save results inside memory
  • Interface for PC comunication
 

Standard accessories

  • C2033X: cable 3-wire with Shuko plug
  • A0050: power adaptor 230V/50 Hz
  • KITGSC5: kit of 4 cables 2m , 4 alligators e 2 test leads
  • KITTERRNE: bag with 4 cable banana/banana + 4 metal rods
  • Hz
  • TOPVIEW2006: Windows PC software + optical/USB cable C2006
  • BORSA2051: carrying bag
  • Calibration certificate ISO9000
  • User manual
 
GSC57 also include C5700: power cable for 10A continuity test
GSC53N/ ZG47 also include HTFLEX33D: flexible clamp AC 3000A, diameter 174mm, 3 pcs
 

Recommended options

  • C7000/05: 2 cables, 5m length, for 10A test
  • C7000/10: 2 cables, 10m lengt,  for 10A test
  • HT52/05: transducer for air temperature/humidity
  • HT53/05: transducer for lux measurements
  • HTFLEX3003: kit of 3 flexible clamps 300-3000A/1V AC, max diameter 174mm
  • HTFLEX1000: kit of 3 flexible clamp 1000A/1V AC, max diameter 154mm
  • HT96U: clamp 1-100-1000A/1V AC, max diameter 54mm
  • HT97U: clamp 10-100-1000A/1V AC, max diameter 54mm
  • HT903: accessory 3x1-5A/1V for connection to external CT's
  • IMP57: accessory ZLoop/Line at high resolution
 

More products HT ITALIA

HT8100 PROFESSIONAL PROCESS CALIBRATOR WITH MULTIMETER FUNCTIONS

• TRMS
• AC/DC voltage 1000V AC+DC
• AC/DC current 1A AC+DC
• DC 4-20mA current measurement
• DC 0-10V voltage measurement
• DC 4-20mA current generation

 

HT9025T CURRENT CLAMP METER WITH INFRARD CAMERA AND 1500V DC

• TRMS
• Current measuring range 1000A
• AC/DC current AC+DC
• AC/DC voltage 1000VAC/1500VDC
• IR Resolution 120 x 120 pxl

 

THREE-PHASE POWER QUALITY ANALYZER HT PQA820

• 3 system types: Single-phase, three-phase 3-wire, three-phase 4-wire.
•  Configurable directly from Smartphone or Tablet.
•  Fast trips and detailed zoom of all sizes.
•  Real Time.
•  Energy consumption logger.
•  383 parameters can be displayed simultaneously.
•  Technology and absolute simplicity.
•  Harmonics Jump function.

 

DIGITAL MULTIFUNCTION VDE MULTIMETER HT ITALIA M74

• ContiDC Voltage
• AC TRMS Voltage
• nuity test of protective conductors with 200mA
• Insulation Resistance with 250, 500VDC
• Trip-out time of RCDs type AC Standard
• Test current selectable; 30mA, 30x5mA, 100mA, 300mA
• Global Earth Resistance without RCD tripping
• Global Earth Resistance with 0.1Ohm resolution

 

I-V600 ADVANCED MULTIFUNCTION INSTRUMENT FOR I-V CURVE MEASUREMENTS UP TO 1500V AND 40A

• I-V curve tracing of mono-facial and bi-facial PV modules and strings up to 1500V/40A according to IEC/EN60891
• SOLAR03 remote unit with Bluetooth connection
• Up to 3 reference cells to measure front-side and rear-side radiation according to IEC TS 60904-1-2
• Database of over 30,000 photovoltaic modules manageable via connection with the new HT AGORÀ software (downloadable in the Download Area)

 

PROFESSIONAL MULTIMETER CABLE VERIFIER FOR LAN VDE CHECKING HT ITALIA M75

• DC Voltage
• AC TRMS Voltage
• Continuity test of protective conductors with 200mA
• Insulation Resistance measurement with 500VDC
• Global Earth Resistance without RCD tripping
• Test executed on twisted pairs cables UTP and STP with RJ45 connector
• Quickly selection of cables pairs

 

EARTH RESISTANCE AND LOOP IMPEDANCE RCD TESTER HT ITALIA SPEED 418

• Tripping time on RCD type A, AC General and Selective with currents 10, 30,100, 300, 500mA
• Tripping time on RCD type AC General with currents 30, 30x5, 100, 300mA
• Tripping current on RCD type A, AC General and Selective Global earth resistance without RCD tripping
• Line/Loop impedance, also with high-resolution (0.1m )( with optional accessory IMP57)
• Optical/USB interface for connection to PC

 

SINGLE/ THREE-PHASE NETWORK AC CURRENT DATA LOGGER HT ITALIA XL421/ XL422

• TRMS AC current measure up to 2500A
• Recording with sampling programmable period
• Manual activation of recording
• RS-232 interface
• Programming with DATALINK software

 

HT PQA924 CLASS S POWER QUALITY AND ENERGY ANALYZER

• AC voltage in single-phase and three-phase systems
• AC current in single-phase and three-phase systems
• Cosphi, Power Factor, K-Factor
• Voltage unbalance
• Flicker
• Active, Reactive, and Apparent power/energy
• Voltage and current harmonic amplitude and phase up to the 63rd order with THD% calculation

 

HT GSC60 MULTIFUNCTION ELECTRICAL INSTALLATION TESTER WITH POWER QUALITY ANALYSIS

• Insulation with voltage 50, 100, 250, 500, 1000VDC
• Three-phase Power quality and Energy consumption analysis
• 632 parameters can be recorded for over two months
• Voltage/current vector diagram
• Voltage/current waveforms
• Tables or histograms of Harmonics and THD%
• Integrated WiFi connection and compatibility with HTANALYSIS App