Primary Injection Current Set 2000A Cotel VE 1200-N

Code: Cotel VE-1200-N


 

Datasheet PDF, 1.11 Mb

Description

VE 1200-N Primary injection set

 

Single-phase test set for high currents. The easy to use and rugged VE 1200-N is particularly adapted to primary testing : transformer ratios, auxiliaries, bushings, circuit breakers, overcurrent relays, etc.

 

The VE1200-N has a built-in digital measurement and control module.

The latest version has a big graphical display for easy reading of the TRMS current and control of the injection.

 

 

OVERVIEW

- Flight Case with wheels,

- Size : 570 x 310 x 510 mm,

- Weight ± 52 kg.

 

SPECIFICATIONS

Power supply :

- 230 Vac 50/60 Hz.

 

Protection :

Supply and generator by circuit breakers and electronic control.

 

Generator :

Single generator configured for current three ranges : 1A, 15A and 2000A.

 

The output current can be adjusted to

650A for 15 minutes

1000A for 5 mn

2000A for 30 seconds.

 

DIGITAL DISPLAY

The new control enables recording of trip time, threshold and CT ratio in an internal

FLASH memory. These data can be downloaded to a computer with windows® XP/2000/VISTA.

The data connexions are USB and RS232.

 

Internal ammeter :

- 2 ranges 0-200 A and 200-2000 A with automatic selection

- Precision : 1%.

 

External ammeter :

- 2 ranges 0-1A and 1-10A

- Precision : 0.5 %

- The external ammeter has a dedicated menu for measuring the ratio and phase shift of a Current Transformer.

 

Time measurement :

- Internal START/STOP trigger

- External START.STOP trigger

- free of voltage contact or AC/DC 12 to 250 V

- precision : 0.02 % +-1ms

- range measurement : 9999.999 s

 

 

 

Recommended options

Options

- Software to edit test reports and record data :MCF-ACQ

 

Set of cables :

VE1200-CA-3M-ETRI 2x 3m section 190 mm² with clamp

 

More products COTEL

PRIMARY AND SECONDARY INJECTION CURRENT SET FOR PROTECTIVE RELAY TESTING COTEL MG 40S-N

• High current up to 300A for primary injection
• The easiest and fastest way to test self powered relays
• Specifically adpated ranges for self powered relays up to 20A for secondary injection
• Single commutator to test classical relays
• rugged and light weight conception
• True RMS measurement

 

THREE-PHASE PROTECTIVE RELAY TESTING SET COTEL HEXAN II

• Current (25 A/ph) & Voltage (300 V/ph)
• Extremely versatile
• Very user friendly
• Run from PC OR Custom interface
• Modular & Configurable
• Easily portable

 

VOLTAGE-CURRENT SET FOR PROTECTIVE RELAY TESTING COTEL MG 50-N

• 300A max Current
• 250V Voltage
• in-built digital measurement and control module
• Light aluminium case
• data connexions are USB and RS232

 

HIGH VOLTAGE BREAKER ANALYZER COTEL CP 4 TR

• 4 time inputs
• Integrated breaker control
• Resolution 0.1 ms
• CP 4 is a user friendly chronometer to measure the
• - Synchronisation of breaker
• - Opening time of main contact
• - Closing time of main contact

 

DIGITAL TIMER FOR TESTING BREAKERS COTEL CP 1-N

• 2 Inputs voltage or dry contacts configurable(11 to 250 Vdc/ 35 to 250 Vac)
• inputs are isolated from one another and relative to the earth . Insulation 750Vac/1000Vdc
• Connection on 4 mm safety sockets..
• Time measurements from 1ms to 774.999s
• Accuracy : +-1 ms +-0.02% of the value
• Protected with varistor and fuse

 

SINGLE PHASE CURRENT GENERATOR FOR SECONDARY INJECTION COTEL MG 30-N

• 125A max Current
• 250V Voltage
• Flight Case enclosure
• connexions are USB and RS232
• Time measurement

 

THREE-PHASE PROTECTIVE RELAY TESTING SET COTEL HEXAN C

• Current (25 A/ph) & Voltage (300 V/ph)
• Extremely versatile
• Very user friendly
• Run from PC OR integrated Custom interface
• Modular & Configurable
• Rugged and portable

 

PRIMARY INJECTION CURRENT SET 1300A COTEL MCF 750-N

• High current test set up to 1300A
• 2 outputs with high current 3V(1300A) et 5V(750A)
• Low ranges to inject current up to 32A
• Injection set compact and rugged
• True RMS measurement
• Voltage generator up to 250Vac
• Measurement of ratio and direction of current transformer

 

PROTECTIVE RELAY TESTING SET COTEL SMARTCASE

• 250 Aac Current Generator
• 300 Vac Voltage Generator
• 330 Vdc Voltage Generator
• Frequency generator Range : 40 to 70 Hz, Resolution : 0.01 Hz
• Phase shift Range: -180° / +180° or 0° / 360°
• Digital Timer

 

PRIMARY INJECTION CURRENT SET 2000A COTEL VE 1200-N

• Single generator configured for current three ranges : 1A, 15A and 2000A
• External ammeter
• Time measurement
• recording of trip time, threshold and CT ratio in an internal FLASH memory
• data connexions are USB and RS232