Description
The HEXAN-C applies the latest technologies for component
integration and power supply design to offer a complete three-phase test system of reduced
dimensions and weight. The experience acquired during the development of the
HEXAN enables us to integrate a custom interface into the front panel. Control by software
is also possible for complex relays or those which require more automation.
THE HEXAN-C is particularly adapted to the testing of electric protection relays, as well as
to the verification of meters and converters
.
The integrated custon interface displays and enables easy adjustment of the three voltages,
the three currents, the frequency, the phase angle of electrical networks generated by
the HEXAN. A simple menu accesses the testing of reclosers, voltage decoupling protections,
neutral shifting…
The double network for switching instantaneously between good and faulty networks with
digital timer synchronising is very user friendly.
The alternative control by PC is available with the HEXAN software. The connexion is
easy with the serial RS232 or USB on the front panel. The Manusoft software supplied
gives the the user a simple front panel on the PC screen with potentiometers having advanced
tools. Injecting is aided by the Fresnel diagram. The software is compatible with windows
® XP/2000/VISTA.
Standard accessories
HEXAN test software modules
AH-PDMI Minimum Impedance Relay (Railway application)
AH-PRODI Distance Protection (Electrical transmission)
AH-CTF Generator Protection
AH-SC Synchro coupler
AH-MITI Overcurrent protection (constant & inverse time relays)
AH-SMARTEST Automatic relay tester & state sequencer
AH-RH7T Harmonic generator
Recommended options
More products COTEL
|
PRIMARY AND SECONDARY INJECTION CURRENT SET FOR PROTECTIVE RELAY TESTING COTEL MG 40S-N
• High current up to 300A for primary injection |
|
PRIMARY INJECTION CURRENT SET 1300A COTEL MCF 750-N
• High current test set up to 1300A |
|
HIGH VOLTAGE BREAKER ANALYZER COTEL CP 4 TR
• 4 time inputs |
|
PRIMARY INJECTION CURRENT GENERATOR 4000A COTEL VE 2000-N
• High current test set up to 4000 A (PCITS) |
|
SINGLE PHASE CURRENT GENERATOR FOR SECONDARY INJECTION COTEL MG 30-N
• 125A max Current |
|
PRIMARY INJECTION CURRENT SET 2000A COTEL VE 1200-N
• Single generator configured for current three ranges : 1A, 15A and 2000A |
|
PROTECTIVE RELAY TESTING SET COTEL SMARTCASE
• 250 Aac Current Generator |
|
DIGITAL TIMER FOR TESTING BREAKERS COTEL CP 1-N
• 2 Inputs voltage or dry contacts configurable(11 to 250 Vdc/ 35 to 250 Vac) |
|
THREE-PHASE PROTECTIVE RELAY TESTING SET COTEL HEXAN II
• Current (25 A/ph) & Voltage (300 V/ph) |
|
THREE-PHASE PROTECTIVE RELAY TESTING SET COTEL HEXAN C
• Current (25 A/ph) & Voltage (300 V/ph) |