Primary Injection Current Set 1300A Cotel MCF 750-N

Code: Cotel MCF-750-N


 

Datasheet PDF, 1.11 Mb

Description

MCF 750-N Lightweight primary injection set

 

High current test set up to 1300A

- 2 outputs with high current 3V(1300A) et 5V(750A)

- Low ranges to inject current up to 32A

- Injection set compact and rugged

- True RMS measurement

- Voltage generator up to 250Vac

- Measurement of ratio and direction of current transformer

 

OVERVIEW

- Flight Case enclosure

- Dimensions : 390 x 310 x 300 mm

- Weight : 21 kg.

SPECIFICATIONS

Power supply :

- 230V 50/60 Hz

Nominal power : 750 VA.

Max power : 2.5 kVA

Protections :

- Power supply and generator by circuit breakers

and electronic control.

Generators :

One AC current generator with voltage

function depending on load.

Current generator : 5 ranges

Output 3V : 500A/5mn ; 750A/85s ; 1300A/10s

Output 5V : 300A/5mn ; 500A/38s ; 750A/8s

Output 25A with maximum voltage 24V

Output 5A/13VA

Voltage output 250V / 2A

These specifications vary as a function of the section

of the cables used, the resistance of the contacts and

the heating of the generator in the test set. Additionally,

for correct operation it is necessary to keep the

instrument on standby for a periodthat is at least as

long as the injection period.

Cables used : 2 cables length 2m section 95 mm²

 

DIGITAL DISPLAY

The new control enables recording of the

trip time, threshold, and CT ratio in an internal

FLASH memory. These data can be downloaded to

a computer with windows® XP/2000/VISTA. The

data connections are USB and RS232.

Internal ammeter :

- 2 ranges 0-130 A and 130-1300 A with automatic

selection

- Precision : 1%

Time measurement :

- Internal START/STOP trigger

- External START.STOP trigger

- free of voltage contact or AC/DC 12 to 250 V

- precision : 0.02 % +-1ms

- range measurement : 9999.999

 

 

Recommended options

Options

- integrated ammeter to measure ther ratio and

direction of a current transformer : MCF500-Aext

- Set of cables

- Software to edit test reports and data records : MCF-ACQ

 

 

More products COTEL

VOLTAGE-CURRENT SET FOR PROTECTIVE RELAY TESTING COTEL MG 50-N

• 300A max Current
• 250V Voltage
• in-built digital measurement and control module
• Light aluminium case
• data connexions are USB and RS232

 

THREE-PHASE PROTECTIVE RELAY TESTING SET COTEL HEXAN C

• Current (25 A/ph) & Voltage (300 V/ph)
• Extremely versatile
• Very user friendly
• Run from PC OR integrated Custom interface
• Modular & Configurable
• Rugged and portable

 

SINGLE PHASE CURRENT GENERATOR FOR SECONDARY INJECTION COTEL MG 30-N

• 125A max Current
• 250V Voltage
• Flight Case enclosure
• connexions are USB and RS232
• Time measurement

 

PRIMARY INJECTION CURRENT GENERATOR 4000A COTEL VE 2000-N

• High current test set up to 4000 A (PCITS)
• Nominal power available on output : 6 kVA
• Maximum power available on output: 15 kVA
• 2 high current outputs on 3V and 6V
• Continuously variable current from 0 to 4000A
• Rugged design in FLIGHT CASE with wheels
• True RMS current measurement
• Multi-function digital timing system
• Ratio and phase shift of CT

 

HIGH VOLTAGE BREAKER ANALYZER COTEL CP 4 TR

• 4 time inputs
• Integrated breaker control
• Resolution 0.1 ms
• CP 4 is a user friendly chronometer to measure the
• - Synchronisation of breaker
• - Opening time of main contact
• - Closing time of main contact

 

PRIMARY AND SECONDARY INJECTION CURRENT SET FOR PROTECTIVE RELAY TESTING COTEL MG 40S-N

• High current up to 300A for primary injection
• The easiest and fastest way to test self powered relays
• Specifically adpated ranges for self powered relays up to 20A for secondary injection
• Single commutator to test classical relays
• rugged and light weight conception
• True RMS measurement

 

PROTECTIVE RELAY TESTING SET COTEL SMARTCASE

• 250 Aac Current Generator
• 300 Vac Voltage Generator
• 330 Vdc Voltage Generator
• Frequency generator Range : 40 to 70 Hz, Resolution : 0.01 Hz
• Phase shift Range: -180° / +180° or 0° / 360°
• Digital Timer

 

DIGITAL TIMER FOR TESTING BREAKERS COTEL CP 1-N

• 2 Inputs voltage or dry contacts configurable(11 to 250 Vdc/ 35 to 250 Vac)
• inputs are isolated from one another and relative to the earth . Insulation 750Vac/1000Vdc
• Connection on 4 mm safety sockets..
• Time measurements from 1ms to 774.999s
• Accuracy : +-1 ms +-0.02% of the value
• Protected with varistor and fuse

 

PRIMARY INJECTION CURRENT SET 1300A COTEL MCF 750-N

• High current test set up to 1300A
• 2 outputs with high current 3V(1300A) et 5V(750A)
• Low ranges to inject current up to 32A
• Injection set compact and rugged
• True RMS measurement
• Voltage generator up to 250Vac
• Measurement of ratio and direction of current transformer

 

PRIMARY INJECTION CURRENT SET 2000A COTEL VE 1200-N

• Single generator configured for current three ranges : 1A, 15A and 2000A
• External ammeter
• Time measurement
• recording of trip time, threshold and CT ratio in an internal FLASH memory
• data connexions are USB and RS232