Digital Insulation Megohmmeter 5kV Chauvin Arnoux CA6549

Code: Chauvin Arnoux CA6549


 

Datasheet PDF, 0.72 Mb

Description

In its site-adapted casing, the C.A 6549 insulation tester offers quantitative and qualitative insulation analysis, on a large backlit graphic screen!

 

 

  • measurement range: 10k? to 10T?!
  • 4 fixed test voltages: 500 / 1,000 / 2,500 and 5,000V
  • adjustable test voltage position: 40 to 5,100V in 10V or 100V increments
  • step voltage mode: R(Utest) measurement curve viewed on the screen and gradient calculated automatically in ppm/V
  • DAR, PI and DD quality ratios calculated automatically
  • programmable test length and R(t) measurement curve displayed directly on the screen
  • with indication of measurement t° after measurement, resistance recalculated to reference temperature for reliable and accurate insulation monitoring
  • many other functions: test voltage locking, smooth function, programmable alarms, etc.
  • can record thousands of measurements
  • RS 232 connector for connection to PC or very compact serial printer
  • power supply: rechargeable NiMH battery for 30 days' operating with 10 DAR measurements and 5 PI measurements per day
  • electrical safety: IEC 61010-1 Cat.III 1,000V or Cat.I 2,500V and 61557
  • dimensions: 270x250x180mm; mass: 4.3kg

 

 

 

Standard accessories

C.A 6547 Megohmmeter .................................... P01139702

C.A 6549 Megohmmeter .................................... P01139703

Delivered with a carrying bag containing:

½ 2 safety leads 3 m long with HV plug and HV crocodile clip (red/blue)

½ 1 guarded safety plug 3 m long with an HV plug with rear connection

and an HV crocodile clip (black)

½ 1 lead with rear connection (blue) 0.35 m long

½ 1 mains power cable 2 m long,

½ 1 communication lead,

½ 1 simplified operating manual

½ 1 operating manual in 5 languages

 

More products CHAUVIN ARNOUX

THREE-PHASE ENERGY ANALYZER CHAUVIN-ARNOUX CA8335 QUALISTAR PLUS

• - Voltage ratios: 1 V to 500 kV
• - Mixed sensors: 10 mA to 60 kA depending on sensor
• for quick verification of network quality and simple processing of the results

 

INSULATION RESISTANCE MEGOHMMETER 1KV CHAUVIN ARNOUX CA6541

• insulation: up to 4TO (5 cal.) at 50/100/250/500 and 1,000V DC
• automatic calculation of insulation quality ratios: DAR and PI
• programmable test period and plotting of the R(t) curve (automatic memorisation of 20 samples)
• automatic indication of voltage before and after measurement: 1 to 1000V AC/DC
• resistance: from 0.01O to 400kO
• continuity: 0.01O to +40O (audible beep and lead compensation)
• automatic measurement capacity after each insulation measurement: 0.005 to 4.999 ½F

 

EARTH GROUND RESISTANCE TESTER ON PYLONS CHAUVIN ARNOUX CA6474

• Ideal for earth measurements on pylons
• measurement range: 0.001 O to 99.99 kO
• resolution: 0.001 to 10 O
• no-load voltage: 16 or 32 VRMS
• measurement frequency: 41 Hz to 5,018 Hz
• measurement of resistance of earth stakes: 0.01 O to 100kO
• leakproofing: IP53

 

TRANFORMER RATIO TESTER CHAUVIN ARNOUX DTR8510

• calculate the ratios
• NiMH battery life of up to 10 hours
• Automatic calibration and balancing
• Low-voltage test
• Digital display ½ display of ratios, winding direction - % deviation
• Degauss function

 

DIGITAL INSULATION MEGOHMMETER 500V CHAUVIN ARNOUX CA6521

• insulation: up to 2G? at 250V and 500V DC
• voltage indication before insulation measurement: 0 to 600V AC/DC (blocking if U>25V)
• continuity: -20? to +20? (audible beep)
• giant 400-count display + bargraph (simultaneous reading of measurement and analogue variance)
• back stand for use on a table or on the ground
• long battery life: 6 x 1.5V batteries


EARTH RESISTANCE DIGITAL TESTER CHAUVIN ARNOUX CA6423

• earth resistance: 0.00 to 2,000O (3 cal.)
• 3 fault presence indicators to validate the measurement
• measurement frequency: 128Hz
• connection of rods to colour-coded terminals
• a removable captive connection strip between H and S for measurement of 2-wire resistance
• large 2,000-count digital display with 18mm digits: excellent readability


DIGITAL INSULATION MEGOHMMETER 5KV CHAUVIN ARNOUX CA6549

• measurement range: 10k? to 10T?!
• 4 fixed test voltages: 500 / 1,000 / 2,500 and 5,000V
• adjustable test voltage position: 40 to 5,100V in 10V or 100V increments
• step voltage mode: R(Utest) measurement curve viewed on the screen and gradient calculated automatically in ppm/V
• DAR, PI and DD quality ratios calculated automatically
• programmable test length and R(t) measurement curve

 

INSULATION MEGOHMETER 1KV CHAUVIN ARNOUX CA6543

• insulation: up to 4TO (5 cal.) at 50/100/250/500 and 1,000V DC
• automatic calculation of insulation quality ratios: DAR and PI
• programmable test period and plottingof the R(t) curve
• automatic indication of voltage before and after measurement: 1 to 1,000V AC/DC
• resistance: 0.01O to 400kO
• continuity: 0.01O to +40O (audible beep and lead compensation )

 

MULTIFUNCTION ELECTRICAL INSTALLATION TESTER CHAUVIN ARNOUX CA6116

• ALL-IN-ONE tool for electrical installation testing
• compliance with the national and international standards (IEC 60364-6, NF C 15-100, VDE 100, XP C 16-600...
• design, ergonomics, simplicity, rapidity and accuracy
• Suitable for all types of neutral systems (TT, TN, IT)
• large backlit graphic screen

 

DIGITAL INSULATION MEGOHMMETER 500V CHAUVIN ARNOUX CA6533

• insulation: up to 20G? at 50V, 100V, 250V and 500V
• voltage indication before insulation measurement: 0 to 600V AC/DC (blocking if U>25V)
• resistance: 0 to 400kO
• giant 4,000-count display + bargraph
• backlit display
• programmable alarms