Digital Insulation Megohmmeter 5kV Chauvin Arnoux CA6549

Code: Chauvin Arnoux CA6549


 

Datasheet PDF, 0.72 Mb

Description

In its site-adapted casing, the C.A 6549 insulation tester offers quantitative and qualitative insulation analysis, on a large backlit graphic screen!

 

 

  • measurement range: 10k? to 10T?!
  • 4 fixed test voltages: 500 / 1,000 / 2,500 and 5,000V
  • adjustable test voltage position: 40 to 5,100V in 10V or 100V increments
  • step voltage mode: R(Utest) measurement curve viewed on the screen and gradient calculated automatically in ppm/V
  • DAR, PI and DD quality ratios calculated automatically
  • programmable test length and R(t) measurement curve displayed directly on the screen
  • with indication of measurement t° after measurement, resistance recalculated to reference temperature for reliable and accurate insulation monitoring
  • many other functions: test voltage locking, smooth function, programmable alarms, etc.
  • can record thousands of measurements
  • RS 232 connector for connection to PC or very compact serial printer
  • power supply: rechargeable NiMH battery for 30 days' operating with 10 DAR measurements and 5 PI measurements per day
  • electrical safety: IEC 61010-1 Cat.III 1,000V or Cat.I 2,500V and 61557
  • dimensions: 270x250x180mm; mass: 4.3kg

 

 

 

Standard accessories

C.A 6547 Megohmmeter .................................... P01139702

C.A 6549 Megohmmeter .................................... P01139703

Delivered with a carrying bag containing:

½ 2 safety leads 3 m long with HV plug and HV crocodile clip (red/blue)

½ 1 guarded safety plug 3 m long with an HV plug with rear connection

and an HV crocodile clip (black)

½ 1 lead with rear connection (blue) 0.35 m long

½ 1 mains power cable 2 m long,

½ 1 communication lead,

½ 1 simplified operating manual

½ 1 operating manual in 5 languages

 

More products CHAUVIN ARNOUX

INSULATION MEGOHMMETER 500V CHAUVIN ARNOUX CA6511

• insulation: up to 1,000MO (1 cal.) at 500V DC
• AC voltage: 0 to 600V
• continuity: -10? to +10? (I=200mA)
• automatic testing of absence of voltage by direct measurement
• single input on two colour-coded terminals


EARTH GROUND RESISTANCE TESTER ON PYLONS CHAUVIN ARNOUX CA6472

• 5 tools in 1 with this tester
• extensive measurement ranges: 0.001?to 100 k?
• analysing the frequency behaviour of the earthing systems (from 41 Hz to 5 kHz)
• high-level, expert calculation capabilities
• IP 53 leakproofing

 

EARTH RESISTANCE DIGITAL TESTER CHAUVIN ARNOUX CA6423

• earth resistance: 0.00 to 2,000O (3 cal.)
• 3 fault presence indicators to validate the measurement
• measurement frequency: 128Hz
• connection of rods to colour-coded terminals
• a removable captive connection strip between H and S for measurement of 2-wire resistance
• large 2,000-count digital display with 18mm digits: excellent readability


EARTH GROUND RESISTANCE TESTER CHAUVIN ARNOUX CA6460

• 3-in-1 tester: resistivity, earth, coupling
• measurement range: 0.00 to 2,000? (3 automatic calibres)
• change from 4-wire method to 3-wire method thanks to 1 removable captive bar between E and ES
• 3 fault presence indicators to validate measurement
• measurement frequency: 128Hz

 

ELECTRICAL INSTALLATION TESTER CHAUVIN ARNOUX CA6114

• automatic installation status test immediately after connection
• measurement of voltage (10 to 440V AC/DC) and frequency (15.3 to 450Hz)
• installation insulation measurement at 500V
• standard earth connection resistance measurement (1 stake + loop method)
• PE conductor continuity test
• measurement of internal loops
• testing of RCDs up to 500mA (exact tripping time and current)
• phase rotation testing

 

MULTIFUNCTION ELECTRICAL MACHINE TESTER CHAUVIN ARNOUX CA6155

• Measurements in compliance with the IEC 60204 Ed.5 / VDE701/702 / IEC 61439 (IEC 60439) standards
• 200 mA and 10 A continuity measurements
• Insulation resistance at 250 VDC and 500 VDC
• Dielectric test at 1,000 V / 1,890 V / 2,500 V
• Leakage current measurement by substitution method
• Differential leakage current
• Contact leakage current
• Mains power-lead polarity test

 

TRANFORMER RATIO TESTER CHAUVIN ARNOUX DTR8510

• calculate the ratios
• NiMH battery life of up to 10 hours
• Automatic calibration and balancing
• Low-voltage test
• Digital display ½ display of ratios, winding direction - % deviation
• Degauss function

 

ENERGY POWER ANALYZER CHAUVIN-ARNOUX CA8230

• Voltage range: 6VRMS to 600VRMS AC+DC
• AC current range: 5mA to 6,500A
• DC current range: 1A to 1,700A
• Values: Min., Max., Avg., Peak (+/-), CF
• Power: W, VA, var, DF, THD, cos f, tan f
• Energy: Wh, VAh, varh
• Harmonics: up to the 50th order
• IEC1010/EN61010: Cat.III-600V

 

DIGITAL INSULATION MEGOHMMETER 100V CHAUVIN ARNOUX CA6531

• insulation: up to 400MO at 50V and 100V
• AC voltage measurement: 0 to 400V
• voltage indication before measurement of insulation: 0 to 600V AC/DC (blocking if U>25V)
• resistance: 0 to 40kO
• capacity: 0 to 4000nF
• current: 0 to 400mA AC/DC


SOLAR PANEL EFFICIENCY TESTER CHAUVIN ARNOUX FTV100 GREENTEST

• electrical power survey
• Calculation of solar panel efficiency
• Calculation of inverter efficiency
• Voltage up to 1,000 VDC / 600 VAC
• Current up to 1,400 ADC / 3,000 AAC
• AC/DC power: 20,000 WDC / 1,200 WAC