Sonda inalta tensiune osciloscop atenuare 100x Testec TT-HV

Cod: Testec TT-HV


 

Descriere

TT-HV 150  100:1, 300MHz

Attenuation Ratio: x100

Input Impedance: 100Ω, 4 pF

Bandwidth: 300 MHz

Rise Time: 1,2 ns

Cable Length: 1,2 m

Compensation Range: 10..50 pF

Max. Input Voltage: 1500Vp CAT I, DC incl. Peak AC (derating with frequency)

 

TT-HV 151  100:1, 200MHz

Attenuation Ratio: x100

Input Impedance: 100Ω, 6 pF

Bandwidth: 200 MHz

Rise Time: 1,8 ns

Cable Length: 2,0 m

Compensation Range: 10..50 pF

Max. Input Voltage: 1500Vp CAT I, DC incl. Peak AC (derating with frequency)

 

TT-HV 250  100:1, 300MHz

Attenuation Ratio: x100

Input Impedance: 100Ω, 4 pF

Bandwidth: 300 MHz

Rise Time: 1,2 ns

Cable Length: 1,2 m

Compensation Range: 10..50 pF

Max. Input Voltage: 2500Vp CAT I, DC incl. Peak AC (derating with frequency)

 

TT-HV 251  100:1, 200MHz

Attenuation Ratio: x100

Input Impedance: 100Ω, 6 pF

Bandwidth: 200 MHz

Rise Time: 1,8 ns

Cable Length: 2 m

Compensation Range: 10..50 pF

Max. Input Voltage: 2500Vp CAT I, DC incl. Peak AC (derating with frequency)

 

Alte produse TESTEC

SONDA INALTA TENSIUNE OSCILOSCOP ATENUARE 100X TESTEC TT-HV

• TT-HV 150 100:1, 300MHz
• TT-HV 151 100:1, 200MHz
• TT-HV 250 100:1, 300MHz
• TT-HV 251 100:1, 200MHz


SONDA TENSIUNE OSCILOSCOP ATENUARE 10X FRECVENTA INALTA TESTEC TT-HF400

• TT-HF 412 10:1 - 1,2m, 350MHz
• TT-HF 420 10:1 - 2,0m, 270MHz


SONDA PASIVA OSCILOSCOP ATENUARE 1X/10X TESTEC TT-MF300

• TT-MF 312 1:1/10:1 1,2m, 20MHz/250MHz
• TT-MF 316 1:1/10:1 - 1,6m, 13MHz/220MHz
• TT-MF 320 1:1/10:1 - 2,0m, 10MHz/190MHz


SONDA ACTIVA DIFERENTIALA OSCILOSCOP 200MHZ TESTEC TT-SI200

• TT-SI 200 1:10, 200MHz
• Bandwidth: 200MHz
• Attenuation Ratio: : x10
• Accuracy: ± 1%
• Rise Time: 1,75ns
• Input Impedance: 500kW / 7pF


SONDA PASIVA OSCILOSCOP ATENUARE 1X/10X TESTEC TT-LF300

• TT-LF 312 1:1/10:1 - 1,2m, 15MHz/150MHz
• TT-LF 316 1:1/10:1 - 1,6m, 12MHz/130MHz
• TT-LF 320 1:1/10:1 - 2,0m, 10MHz/100MHz


SONDA DE TEST SMD-URI PENTRU MULTIMETRU, RLC-METRU TESTEC TT-22100

• TT-22100 Cable Length: 100cm, Connector: 2x 4mm Plug
• TT-22110 Max. Current: 2A, Connector: BNC-Plug


SONDA TENSIUNE OSCILOSCOP ATENUARE 10X TESTEC TT-HF200

• TT-HF 212 10:1 - 1,2m, 300MHz
• TT-HF 220 10:1 - 2,0m, 230MHz


SONDA TENSIUNE OSCILOSCOP ATENUARE 1X TESTEC TT-HF100

• TT-HF 112 1:1 - 1,2m, 40MHz
• TT-HF 120 1:1 - 2,0m, 30MHz
• TT-HF 212 10:1 - 1,2m, 300MHz


SONDA ACTIVA OSCILOSCOP FRECVENTE INALTE DC..1.3GHZ TESTEC TT-AP

• TT-AP 1300 x10, DC..1.3GHz
• Bandwidth: DC 1,3GHz
• Attenuation Ratio: x10
• Rise Time: <0,25ns


SONDA PASIVA OSCILOSCOP ATENUARE 10X TESTEC TT-MF200

• TT-MF 212 10:1 - 1,2m, 250MHz
• TT-MF 216 10:1 - 1,6m, 220MHz
• TT-MF 220 10:1 - 2,0m, 190MHz