TDR 2-canale localizare defecte cablu Megger TDR2000/3 1003-036, TDR2000/3P 1003-037

Cod: Megger TDR2000/3 1003-036 TDR2000/3P 1003-037


 

Brosura produs PDF, 0.2 Mb
       

Descriere

  • Comprehensive Dual Channel capability with dual aspect display.
  • AUTO set up mode for instant use.
  • Ultra fast pulse for near end fault identification.
  • Xpert guidance to potential fault.
  • IP54 rating offers real life working.
  • Designed for use on all metallic paired cables.

 

TDR2000/3 is a highly portable, high resolution, compact, dual channel time domain reflectometer with a large colour screen for locating faults on paired metallic cables in applications as diverse as street lighting, telephony and CATV

With a best resolution of 0.1m the TDR2000/2 has a 20km maximum range depending on the velocity factor selected and the cable type. Five output impedances are available (25, 50, 75, 100 and 125 ohms) and with an auto impedance matching feature and a velocity factor between 0.2 and 0.99 to meet any cable test requirements.

Powered by Li-ion rechargeable batteries, it is available in two configurations.

TDR2000/3 - high resolution TDR with backlit colour display and powered by Li-ion rechargeable battery batteries, complete with 2 pairs of mini-clip test leads.

TDR2000/3P - high resolution TDR with backlit colour display and powered by Li-ion rechargeable battery batteries, complete with 2 pairs of fused test leads.

 

Accesorii standard

TDR2000/3 Time Domain Reflectometer 1003-036

TDR2000/3P Time Domain Reflectometer 1003-037

Download Kit 1003-353

Terminal Adaptor Kit 1003-218

 

Included Accessories

Carry Case 1003-217

Dual Fused test leads (TDR2000/3P) 1002-136

User Guide CD 2003-074

Dual mini-clamp test leads (TDR2000/3) 6231-654

Carry Case 1003-217

 

Optional accessories

AC-DC Charger 1003-352

Pair mini-clamp test leads 6231-652

Replacement Battery 1002-552

Pair Fused test leads 1002-015

 

Alte produse MEGGER

SARCINA TESTARE DESCARCARE BATERII UPS-URI MEGGER TORKEL-840 TORKEL-860 BS-49094 BS-49096

• used for battery systems ranging from 12 to 250 V
• Batteries can be tested "in service"
• Unit adjusts to include load currents in the test parameters
• User adjustable alarm and shutdown points to avoid excessive discharge
• Easily expandable for larger battery banks using TXL extra load units (option)
• Computerized test operation using TorkelWin software (option)

 

TESTER RAPORT TRANSFORMARE, DEPLASARE FAZA, REZISTENTA INFASURARE TRANSFORMATOARE MEGGER TTR100

• Tests turns ratio, phase displacement, excitation current, vector group, winding resistance and polarity
• Fully automatic; fast; easy-to-use; handheld; robust; lightweight
• Battery powered with power-saving and shutdown function
• Alphanumeric keyboard
• RS232 for data transfer and printing
• Stores 200 test results and 100 user-defined transformer test settings

 

TESTER TDR LOCALIZARE DEFECTE CABLURI MEGGER TDR1000/3

• minimum resolution of 0.1 m and a 5 km maximum range
• Simple operation.
• AUTO set up for instant use.
• Ultra fast pulse for near end fault identification.
• Trace HOLD feature to allow comparison between cables.
• IP54 rating offers real life working.
• Designed for use on all metallic cable pairs.

 

TRUSA TESTARE RIGIDITATE ULEI ELECTROIZOLANT MEGGER OTS60PB OTS80PB

• portable 60 kV and 80 kV oil test sets
• Lightest - miniumum weight 16 kg
• Lock in precision - oil vessel with lockable adjustment
• Bright 3.5 inch colour display visable out doors
• Suitable for mineral, ester and silicon oils
• Trip detection circuit with direct measure ment of voltage and current
• Ultra fast (<10 µs) HV switch off time

 

BATTERY GROUND FAULT LOCATOR MEGGER - BGL

• Ground faults in ungrounded dc battery systems easily located
• Operates in high electrical noise environment
• Simplifies fault tracing by identifying fault characteristic (resistive and capacitive) magnitudes

 

KARL FISCHER MOISTURE IN OIL TEST SETS MEGGER ½ KF875 AND KF-LAB MKII

• Coulometric Karl Fischer titrimetry
• KF875 optimized for insulating oil with an SG of 0.875, completely portable
• KF-LAB MkII offers greater flexibility, versatility and sample data input than the KF875; also completely portable
• KF-LAB MkII analyzes materials with an SG between 0.6 & 1.4, plus insulating oils with an SG of 0.875

 

UNIVERSAL CIRCUIT BREAKER TEST SETS MEGGER DDA-3000 AND DDA-6000

• Model DDA-1 Digital Data Acquisition Instrumentation and Control System
• High-current output: 60,000 A for Model DDA-6000; 35,000 A for Model DDA-3000
• Digital signal processing (DSP) technology
• Variable pulse time and firing angle output current control
• Compliant with NEMA AB-4 test guidelines

 

PUNTE PENTRU MASURAT TANGENTA UNGHIULUI DE PIERDERI DIELECTRICE MEGGER DELTA4000

• fully automatic 12 kV insulation power factor / dissipation factor (tan delta) test set
• Voltage: 25 V to 12 kV, 1 V resolution
• Current : 0 to 5 Amps, 0.1 µA maximum resolution
• Capacitance: 0 to 100 µF, 0.01 pF maximum resolution
• Inductance: 6 H to 10 MH, 0.1 mH maximum resolution
• Power factor PF : 0-100% (0-1), 0.001% maximum resolution
• Dissipation factor DF : 0-100 (0-10,000%), 0.001% maximum resolution
• Watt Loss: 0 to 2 kW
• Automatic and manual operation
• Accurate and repeatable measurement results with high noise suppression
• Lightweight, rugged two-piece design

 

MICROHMMETRU 10A MEGGER DLRO10HD

• High or low output power selection for condition diagnosis
• Rechargeable battery or line power supply, continuous operation, even with dead battery
• 10 A for 60 seconds, less time waiting to cool, great for charging inductance
• High input protection to 600 V, inadvertent connection to line or UPS voltage will not blow a fuse
• Heavy duty case: IP 65 lid closed, IP54 operational (battery operation only)
• Rotary switch selects one of five test modes, including auto start on connection, giving ease of use

 

MICRO OHMMETRU 10A MEGGER DLRO10X

• up to 10A current
• Accurate results in under three seconds
• Auto current reversal cancels standing emfs
• Fuse protected to 600 V
• NiMH battery reduces weight
• 250 mW power limit (with optional override) to avoid heating the test sample