• Test voltages : 60 kV, 80 kV and 100 kV

• Laboratory instruments for measuring insulating oil breakdown voltage
• Lock in precision - oil vessel with lockable adjustment
• Bright 3.5" colour display 
• Suitable for mineral, ester and silicon oils
• Trip detection circuit with direct measurement of voltage and current
• Ultra fast (< 10 µs) HV switch off time

 

Megger’s automatic laboratory oil test sets perform accurate breakdown voltage tests on mineral, ester and silicon insulating liquids. Moulded test vessels give repeatable results with lock in precision electrode gap setting adjustment wheels. The transparent, shielded lid and large test chamber enable easy access to the test vessel. 

All three laboratory models are fitted with a 12 key alphanumeric keypad to facilitate entry of test ID, filenames, notes etc. Alpha characters are entered by repetitive pressing on a key, the same way as text is entered modern cellular telephones.

 

Accesorii standard

OTS60AF configured*

OTS80AF configured*

OTS100AF configured*

 

Included accessories (on all configurations)

Vessel 400 ml assembly

Magnetic bead stirrers (2 off)

Magnetic bead retriever

Electrode gauge set 1, 2, 2.5, 2.54 mm 1002-144

User manual CD

PowerDB Lite software

 

Configured accessories (to order additional or spares)

IEC60156 electrode Set - 12.7 mm spherical (2),36 mm mushroom (2) 1001-477

ASTM D877/1816 electrode set - 25.4 mm cylindrical (2 std, and 2 none std), 36 mm mushroom (2) 1001-478

Full electrode set ASTM and IEC electrodes 1001-479

Vessel lid mounted impeller (ASTM D1816) for use with 400 ml vessel 1001-102

 

Optiuni recomandate

Optional accessories

Vessel 400 ml assembly (no electrodes supplied) 1001-473

Vessel 150 ml assembly (no electrodes supplied) 1001-474

VCM100D digital voltage checker 1001-105

VCM80D digital voltage checker 1001-801

Printer paper, 1 roll (MOV applies) (4 rolls supplied if printer configured) 25995-001

Barcode reader, USB 1001-047

 

Alte produse MEGGER

TDR 2-CANALE LOCALIZARE DEFECTE CABLU MEGGER TDR2000/3 1003-036, TDR2000/3P 1003-037

• best resolution of 0.1m the TDR2000/2 has a 20km maximum range
• Comprehensive Dual Channel capability with dual aspect display.
• AUTO set up mode for instant use.
• Ultra fast pulse for near end fault identification.
• Xpert guidance to potential fault.
• IP54 rating offers real life working.
• Designed for use on all metallic paired cables.

 

MEGAOHMMETRU REZISTENTA DE IZOLATIE 5KV MEGGER MIT525/2

• Testare diagnostică cu suită completă de teste
• PI Predictor™ reduce timpul de testare la jumătate
• Testare precisă cu RE>Act™
• Stocare încorporată şi export ușor de date
• Conceput pentru testare sigură pe teren

 

MEGGER MPAC208 CAMERA ACUSTICA DETECTIE SCURGERI GAZ, DEFECTE MECANICE SI DESCARCARI PARTILE ELECTRICE

• Identifică rapid problemele
• Cuantifică scurgerile și pierderile de energie
• Informații fiabile despre descărcările parțiale (PD)
• Funcționează în medii zgomotoase
• Suprapunere termică opțională
• Disponibilă într-un kit complet

 

TRUSA MASURA TANGENTA UNGHI DE PIERDERI TANGETA DELTA MEGGER DELTA4310

• fully automatic 12 kV insulation power factor / dissipation factor (tan delta) test set
• Voltage: 25 V to 12 kV, 1 V resolution
• Current : 0 to 5 Amps, 0.1 µA maximum resolution
• Capacitance: 0 to 100 µF, 0.01 pF maximum resolution
• Inductance: 6 H to 10 MH, 0.1 mH maximum resolution
• Power factor PF : 0-100% (0-1), 0.001% maximum resolution
• Dissipation factor DF : 0-100 (0-10,000%), 0.001% maximum resolution
• Watt Loss: 0 to 2 kW
• Automatic and manual operation
• Accurate and repeatable measurement results with high noise suppression
• Lightweight, rugged two-piece design

 

MEGGER - MS2A CIRCUIT BREAKER AND OVERCURRENT RELAY TEST SET

• Light Weight, Portable Primary Injection Test Instrument
• Overcurrent Relay Testing
• Ground Fault Performance Testing for NEC 230.95
• Circuit Breaker Testing

 

TESTER RAPORT TRANSFORMARE, DEPLASARE FAZA, REZISTENTA INFASURARE TRANSFORMATOARE MEGGER TTR100

• Tests turns ratio, phase displacement, excitation current, vector group, winding resistance and polarity
• Fully automatic; fast; easy-to-use; handheld; robust; lightweight
• Battery powered with power-saving and shutdown function
• Alphanumeric keyboard
• RS232 for data transfer and printing
• Stores 200 test results and 100 user-defined transformer test settings

 

AUTOMATIC OIL CIRCUIT RECLOSER TESTER MEGGER OCR8015/9150

• Preprogrammed test sequences for reclosers and sectionalizers
• High-capacity outputs to test virtually all reclosers
• Accurate duplication of high-voltage test results
• Simple operation and precise test results
• Simplified adjustment of test current

 

HIGHLY PORTABLE MICRO-OHMMETER WITH DUALGROUND SAFETY MEGGER - DLRO100E, DLRO100X AND DLRO100H

• CAT IV 600 V for safe operation
• Light, 100 A, battery powered unit for portability
• High noise immunity for stable readings
• Smooth DC output for circuit breaker testing

 

REFLECTOMETRU LOCALIZARE DEFECTE CABLU MEGGER TDR1000/3P

• TDR1000/3P is suitable for use on both dead or live cables
• Simple operation
• AUTO set up for instant use
• Ultra fast pulse for near end fault identification
• Trace HOLD feature to allow comparison between cables
• IP54 rating offers real life working
• No blocking filters require
• Supplied with fused test leads

 

SARCINA TESTARE DESCARCARE BATERII UPS-URI MEGGER TORKEL-840 TORKEL-860 BS-49094 BS-49096

• used for battery systems ranging from 12 to 250 V
• Batteries can be tested "in service"
• Unit adjusts to include load currents in the test parameters
• User adjustable alarm and shutdown points to avoid excessive discharge
• Easily expandable for larger battery banks using TXL extra load units (option)
• Computerized test operation using TorkelWin software (option)