Tester Instalatii Electrice 50V-1000V Fluke 1653B

Cod: Fluke 1653B


 

Brosura produs PDF, 0.18 Mb

Descriere

  • Test voltage: 50V, 250V, 500V, 1000V
  • Two measurements at once and a dual display
  • PEFC/PSC and loop impedance are measured and displayed in parallel, saves you more than 50% of test time compared to other loop testers.
  • Additional new high current loop mode
  • Faster measurements compared to loop tests with non-trip mode for RCD’s
  • Unique zero adapter for fast, always reliable and accurate test lead and mains cord compensation
  • Earth resistance
  • Fast voltage measurement between L-N, L-PE and N-PE using the mains cord. No need to change measurement connections
  • Earth Volt Touchpad detects raised earth voltages >50 V, indicating potential dangerous situations
  • Supplied with the SureGripâ„¢ test leads and clips which gives the user a comfortable, reliable grip
  • Rotary dial knob indicates clear which function is selected, all functionalities on one spot and no complex multi level menus
  • Large display with backlight, clear symbols and exceptionally wide viewing angle for easy and safe readings
  • PASS/FAIL indication for RCD test results
  • Variable RCD current mode for customized settings
  • Extended Memory

  • Rugged & lightweight Withstands a drop of 1 meter
 

Accesorii standard

  • 6 AA Cell batteries
  • C1600 Hard carrying case
  • Zero Adapter
  • Mains test cord
  • TL165X/STD Standard Test Lead Set
  • Padded carrying strap
  • Quick reference guide
  • TP165X Remote control probe and lead
  • Users manual on CD-ROM
 

Optiuni recomandate

  • ES165X Earth Spike Test Kit (Fluke 1653)
  • TP165X Remote Control Probe
  • DMS DMS Software
  • FlukeView Forms FlukeView Forms Software with cable
 

Alte produse FLUKE

TETER PORTABIL MONOXID DE CARBON CO FLUKE CO-220

• Rugged case and electronics.
• Large LCD displays CO levels from 0 to 1000 ppm.
• Bright back-light allows easy screen viewing under dim lighting conditions.
• Beeper triggers with increasing frequency as CO levels rise.
• MAX Hold function stores and displays the maximum CO level.
• Automatic sensor zeroing and self-test sequence upon start-up.

 

FLUKE TIX500 CAMERA DE TERMOVIZIUNE 320X240

• Fluke TiX500 320x240 pixels, -20 °C..+650 °C
• Fluke TiX520 320x240 pixels, -20 °C..+850 °C
• Fluke TiX560 320x240 pixels, -20 °C..+1200 °C

 

CALIBRATOR TERMOREZISTENTE FLUKE 712B

• measure and simulate (13) different RTD types and resistance
• Measure 4 to 20 mA signals while simultaneously sourcing a temperature signal
• Configurable 0 % and 100 % source settings for quick 25 % linearity checks
• Linear ramp and 25 % step auto ramp based on 0 % and 100 % settings
• Dual inputs and backlit display for easy interpretation of measurements
• Power down settings remembered at power up for easy restart of tests
• 1-year and 2-year specifications and traceable certification of calibration

 

CLESTE AMPERMETRIC WIRELESS FLUKE CNX A3000

• Masuratori de curent c.a. true-RMS la 400 A
• Precizie de 2% la 100 Hz, precizie de 2-1/2% la 500 Hz
• Înregistrare în memorie a pâna la 65.000 masuratori
• Afisaj LCD cu lumina de fundal
• CAT III 600 V; IP42


TESTER PORTABIL TEMPERATURA SI UMIDITATE FLUKE 971

• Temperature range from -20 °C to 60 °C (-4°F to 140 °F)
• Relative humidity from 5 % to 95 %
• Min/Max/Avg Data hold
• Low battery indicator

 

CLESTE AMPERMETRIC DE CURENT TRUE-RMS 600A FLUKE 373

• 600 A AC current measurement with fixed jaw
• 600 V AC and DC voltage measurement
• True-rms ac voltage and current
• 6000 O resistance measurement
• 1000 µF capacitance measurement

 

APARAT MASURA PRIZA DE PAMANT FLUKE 1623-2 GEO

• 3- and 4-pole Fall-of-Potential, earth resistance loop testing
• 4-pole Soil Resistivity testing
• Selective earth ground rod testing using 1 clamp
• Stakeless earth ground rod testing using 2 clamps
• IP56 rated for outdoor use
• Rugged carrying case
• USB data storage and transfer

 

CALIBRATOR TEMPERATURA SI TERMOREZISTENTE FLUKE 712

• -200 to 800ºC Range Measure / simulate RTD (Pt 100)
• 0 to 3200 O Range Measure / simulate resistance
• 0.1 O, 0.1 ºC Resolution

 

MEGOHMETRU DIGITAL MULTIMETRU IZOLATIE 50/ 1000V FLUKE 1587

• Insulation test: 0.01 MO to 2 GO
• Insulation test voltages: 50 V, 100 V, 250 V, 500 V, 1000 V

 

DETECTOR DE TENSIUNE FLUKE 1AC II VOLTALERT

• CAT IV 1000 V for added protection
• 200 V to 1000 V AC