Detector prezenta tensiune Fluke LVD2 Volt Light

Cod: Fluke LVD2 Volt Light


 

Brosura produs PDF, 0.26 Mb

Descriere

  • Dual Sensitivity
  • LED light with 100,000 hour life
  • Detects from 90 to 600 V AC
  • Rated to CAT IV 600 V
  • Dual Levels of Detection
  • Blue indicates proximity to AC Voltage source
  • Red indicates you’re at the source
  • Operating temperature 0 deg C to 50 deg C
  • Ultra-Bright White LED
  • 100,000 hr bulb
  • AAA battery included
 

Optiuni recomandate

 

 

Alte produse FLUKE

FLUKE TI300 CAMERA INFRAROSU TERMOVIZIUNE 240X180 -

• Rezolutie detector : 240 X 180 pixeli
• Domeniu masura temepratura: -20 °C si +650 °C
• Precizie : ± 2 °C sau 2%
• Sensibilitate : = 0,05 °C
• Banda spectru : 7,5 µm si 14 µm
• Ecran tactil capacitiv, rezistent, cu înalta rezolutie de 640x480

 

TESTER PRIZA DE PAMANT FLUKE 1621

• 3-pole Fall-of-Potential earth testing for basic measurements
• 2-pole resistance measurements for added versatility
• 600 V Cat II

 

CALIBRATOR MULTIFUNCTIONAL DE PROCES FLUKE 741B

• 0 to 300 V DC/AC Voltage measure
• 0 to 15 V DC Voltage source / simulate
• 0 to 110 mA DC Current measure
• 0 to 22 mA DC Current source / simulate
• 0 to 11 kO Resistance measure / source / simulate
• 1 to 50 kHz Frequency measure / source / simulate

 

KIT INREGISTRARE TENSIUNE AC LA DISTANTA FLUKE FLK-CNX V3000 KIT

• masuratori de tensiune c.a. si c.c. true-rms, la 1.000 V
• curent c.a. si c.c. true-RMS, cu o rezolutie de 0,01 mA
• Masuratori de tensiune c.a. true-RMS pâna la 1000 V
• memorie de înregistrare de pâna la 65.000 de masuratori
• CAT III 1000 V; CAT IV 600 V; IP42


TERMOMETRU INFRAROSU CU TERMOCUPLU DE CONTACT FLUKE 561 HVAC PRO

• IR Thermometer with K-type thermocouple capability
• IR thermometer for quick measurements up close, or at a distance, without a ladder
• Contact thermometry capability, compatible with all standard mini-connector type K thermocouples, preserves your investment in thermocouples
•  Fabric hook-and-loop fastener pipe probe for superheat and sub-cooling and other contact and ambient measurements
• Single-point laser sighting
• Temperature range of -40 °C to 550 ° C (-40 °F to 1022 °F) covers most industrial and residential applications

 

MULTIMETRU DIGITAL PORTABIL CU DATA LOGGING 4.5 DIGIT FLUKE 287

• 4.5 digit large ¼ VGA display with white backlight
• 50,000 count
• 0.025% basic accuracy
• Logging function with TrendCapture

 

ANALIZOR REZISTENTA INTERNA BATERII FLUKE BT521

• Masuratori cheie: Rezistenta, tensiunea c.c. si c.a., intensitatea c.a. si c.c., variatia de tensiune ale bateriei, frecventa si temperatura bateriei.
• Analiza îmbunatatita a datelor: Comparati rapid tendinte, analizati rezultate si creati rapoarte cu ajutorul software-ului de gestionare a bateriei.
• Raportare usoara: Generati rapoarte PDF pe software-ul PC cu grafice de analiza si tabeluri de date sau trimiteti formatul raportului prin e-mail cu un fisier csv pe aplicatia mobila.
• Comunicatie wireless
• Port USB

 

MULTIMETRU DIGITAL PORTABIL 3.5 DIGIT FLUKE 179

• 3.5 digit
• 6000 count resolution
• 0.09% basic accuracy
• True RMS voltage and current measurements
• Digital display with analog bargraph and backlight
• Temperature measurements

 

CLESTE CURENT CALIBRARE PROCES FLUKE 772

• 0 to 24 mA Current measure / source / simulate
• Best in class 0.2 % accuracy
• 0.01 mA resolution and sensitivity

 

CLESTE AMPERMETRIC DE CURENT TRUE-RMS AC/DC FLUKE 375

• iFlex fexible current probe compatible
• 600 A AC and DC current measurement with fxed jaw
• 2500 A AC current measurement with iFlex (sold separately)
• 600 V AC and DC voltage measurement
• True-rms AC voltage and current
• Frequency measurement to 500 Hz
• 60 k O resistance measurement
• 500 mV dc measurement range
• 1000 µF capacitance measurement