  • Measurement of leakage current with 3 mA range and 1 µA of resolution, for accurate monitoring of insulation erosion
  • Broad range of measurement, from 1 µA up to 60 A, for all installation needs
  • Advanced shielding to ensure accurate results when measuring near other conductors
  • The high durability clamp construction can withstand over 50,000 operations, added ruggedness that extends the life of your leakage clamp.
  • Easy-to-carry, pocket-sized leakage current tester with wide 40 mm (1.5 in) jaw size
  • Handy "Display-Hold" button for capturing leakage current readings in hard-to-reach places
  • Auto power-off, with warning buzzer, saves battery life
  • Conformance to IEC1010 and EMC standard for confident measurements
  • Meets all of the applications and performance classes in safety standard VDE0404-4 and VDE0702 for leakage current and differential current measurement of electrical appliances
 

Accesorii standard

  • Soft carrying pouch
  • Users manual
 

Alte produse FLUKE

CLESTE AMPERMETRIC DE CURENT 400A FLUKE 321

• Measures AC current to 400 A with 0.1 A resolution
• Measures AC volts to 600 V, with 0.1 V resolution to 400.0 V
• Resistance measurement to 400 O
• Precise measurements with 1.8% basic accuracy

 

FLUKE II500 CAMERA ACUSTICA INSPECTIE SI DETECTIE SCAPARI GAZ COMPRIMAT

• Detectare vizuală uÈ™oară, rapidă È™i sigură a scurgerilor de gaz comprimat.
• Ecranul tactil LCD de 7" afiÈ™ează o hartă sonoră SoundMapâ„¢ peste imagini vizuale, facilitând localizarea rapidă a scurgerilor.
• InterfaÈ›a intuitivă nu necesită instruire pentru echipele de întreÈ›inere.

 

POMPA VACUUM GENERARE PRESIUNI JOASE FLUKE 700LTP-1

• hand operated pressure pump
• designed to generate either vacuum to -13 psi / -.90 bar or pressures to 100 psi / 6.9 bar
• Pump can be easily cleaned without disassembly
• Adjustable pressure relief valve with slow-bleed capability. Allows the slow release pressure at a controlled rate
• Quick fit connectors, one for the reference port for connection to a Fluke 700 series pressure module and one to connect to a unit under test
• Slim design, easy to carry and use

 

CALIBRATOR TEMPERATURA SI TERMOREZISTENTE FLUKE 712

• -200 to 800ºC Range Measure / simulate RTD (Pt 100)
• 0 to 3200 O Range Measure / simulate resistance
• 0.1 O, 0.1 ºC Resolution

 

KIT INREGISTRARE TENSIUNE AC LA DISTANTA FLUKE FLK-CNX V3000 KIT

• masuratori de tensiune c.a. si c.c. true-rms, la 1.000 V
• curent c.a. si c.c. true-RMS, cu o rezolutie de 0,01 mA
• Masuratori de tensiune c.a. true-RMS pâna la 1000 V
• memorie de înregistrare de pâna la 65.000 de masuratori
• CAT III 1000 V; CAT IV 600 V; IP42


MEGOHMETRU DIGITAL REZISTENTA IZOLATIE 250V/ 5KV FLUKE 1550C

• Resistance Test range: 1 TO
• Test voltage: 5 kV

 

KIT AUTOMOTIVE MULTIMETRU DIGITAL PORTABIL 4.5 DIGIT FLUKE 88V/A

• 4.5 digit high resolution mode for precise measurements
• 20,000 count
• 0.1% dc accuracy
• Built-in thermometer conveniently allows you to take temperature readings without having to carry a separate instrument
• Conductance for coil testing
• Magnetic hanger (included with kit) for easy set-up and viewing while freeing your hands for other tasks

 

TETER PORTABIL MONOXID DE CARBON CO FLUKE CO-220

• Rugged case and electronics.
• Large LCD displays CO levels from 0 to 1000 ppm.
• Bright back-light allows easy screen viewing under dim lighting conditions.
• Beeper triggers with increasing frequency as CO levels rise.
• MAX Hold function stores and displays the maximum CO level.
• Automatic sensor zeroing and self-test sequence upon start-up.

 

CALIBRATOR MULTIFUNCTIONAL DE PROCES FLUKE 726

• 0 to 100 mV, 0 to 30 V DC Voltage measure
• 0 to 100mV, 0 to 20 V DC Voltage source / simulate
• 0 to 24 mA Current measure / source / simulate
• 0 to 4000 O Resistance measure / source / simulate
• 1 to 15 kHz Frequency measure / source / simulate
• RTDs, thermocouples measure / source / simulate
• pressure measure

 

CALIBRATOR PORTABIL DE BUCLA FLUKE 707

• 0 to 28 V DC Voltage measure
• 0 to 24 mA Current measure
• 0 to 20 mA Current source / simulate
• mA accuracy of 0.015%