Description

  • Isolated variable 1-300 Vdc source
  • Isolated variable 1-240 Vac source
  • 10 ampere continuous current

 

The Vanguard Universal Power Supply Series 2 (UPS-S2) is designed and produced to meet a utility company's substation needs for an independent AC/DC power source. Both the AC and DC Voltage sources are capable of supplying 10 amperes continuously.

 

The variable DC power supply (1-300 Vdc) is ideal for use as a substitute primary power source when station batteries are not available. The UPSS2 is ideal for operating circuit breakers, powering substation relays or for unregulated charging of substation batteries. The AC power supply is a variable isolated power source (1-240 Vac) that can be used to power other equipment in the substation.

 

 

Standard accessories

Part number UPS S2 UPS S2 and cables

Part number UPS S2-CASE UPS S2 shipping case

Part number UPS S2 LEADS UPS S2 test leads

 

More products VANGUARD

THREE-PHASE TRANSFORMER TURN RATIO TESTER VANGUARD ATRT-03

• Highest ratio: 0.8 - 15,000
• Built-in 4.5" thermal printer
• Excitation current measuring
• Phase angle measuring
• Computer interface
• Name-plate turns ratio calculation
• Computed % error based on measured and calculated ratio

 

DC CIRCUIT BREAKER CONTACT LOW RESISTANCE MICROOHMMETER 200A VANGUARD DMOM-200 S3

• 1 to 200A programmable test current
• Resitance range: 1µ?..10m? at 200A to 1µ?..5? at 1A
• Very lightweight: 19.8 lbs. (8.9 Kg)
• Measures circuit breaker contact resistance with safety ground on (with the Dual Ground option)
• Stores test records on-board or on external USB Flash drive
• Built-in 2.5" wide thermal printer

 

DIGITAL CIRCUIT BREAKER ANALYZER VANGUARD CT-8000

• dry-contact inputs 3 channels (9103-UC) or 6 channels (9104-UC)
• timing windows 1 second, 10 seconds, or 20 seconds
• timing resolutions ±50 micro-seconds @ 1 sec. duration
• Fully analyze circuit breaker's performance
• measuring main contact and resistor contact time, stroke, velocity, over-travel, bounce back and contact wipes
• USB computer interface
• Built-in 4.5" wide Thermal Printer

 

WINDING RESISTANCE OHMMETER FOR TESTING HIGH POWER INDUCTIVE TRANSFORMERS VANGUARD WRM-10P

• Range from 1 micro-ohm to 2,000 ohm
• Up to 10 Amperes of test current
• Auto discharge circuit for operator safety
• Built-in 2.5" Thermal Printer, computer interface
• Stores 48 records of 63 readings
• Weighs less than 27 lbs.

 

CURRENT TRANSFORMER TEST SET VANGUARD EZCT-10

• measurement method ANSI/IEEE C57.12.90, IEC 60044-1 and ANSI/IEEE C57.13.1
• output test voltages 0..50 Vac @ 10A max; 0 - 200 Vac @ 10A max; 0 - 1200 Vac @ 1.5A max (5 min on, 10 min off)
• voltage reading range 0..1,250 Vac
• current ratio range 0.8..99: ±0.5%, 100..999: ±1.0%, 1,000..5,000: ±2%
• phase angle measurement 0..360 degrees
• Perform Saturation, Ratio and Polarity Tests
• Fully Automated
• Comprehensive Graphic and Tabulated Test Reports
• Plot Multiple Saturation Curves
• Computer Interface & pc software

 

THREE-PHASE TRANSFORMER WINDING RESISTANCE METER VANGUARD TRM-20

• accurately measure resistance from 1 micro-ohm to 500 Ohms
• Perform three phase test on a transformer without the need to switch cables
• Can provide individual Delta winding resistance values
• Can provide individual Wye (with no neutral) winding resistance values
• Demagnetize transformer after test
• Selectable test current from 1A to 40A
• Computer control via RS-232C, USB, or Bluetooth interface
• Built-in 2.5" wide thermal printer

 

TRANSFORMER WINDING RESISTANCE METER VANGUARD TRM-20

• accurately measure resistance values from 1 micro-ohm to 2,000 Ohms
• Auto-discharge circuit for operator safety
• Demagnetizes transformer after test
• Selectable test current from 1A to 20A
• RS-232C, USB, and Bluetooth computer interfaces
• Built-in thermal printer

 

TRANSFORMER TURN RATIO TESTER VANGUARD ATRT-01

• Displays turns-ratio from 0.8-15,000
• Calculates turns-ratio percentage error
• Displays winding polarity and phase angle
• Displays excitation current
• Battery or AC-powered (ATRT-01B S3 only)
• Standalone or computer-controlled

 

DIGITAL BREAKER ANALYZER FOR CONTACT & SWITCH TIMING VANGUARD CT-3500

• Dry-contact inputs: 3 channels
• Trigger input voltage open/close: 30 ¬ 300 V, DC or peak AC
• Breaker operations: Open, Close, Open-Close, Close-Open
• Timing resolution: ±0.1 millisecond
• Detect Main & Insertion Resistor Contacts on same input
• USB computer interface
• Built-in 2.5" wide Thermal Printer

 

AUTOMATIC THREE-PHASE TRANSFORMER TURN RATIO METER VANGUARD ATRT-03A

• Capable of detecting 130 different 3-phase transformer types defined by ANSI, IEC, and Australian standards plus phase shifting transformers
• Store up to 128 transformer test-plans in Flash EEPROM
• Store up to 112 test records in Flash EEPROM
• Built-in USB Flash Drive Interface
• Computer Interface (RS-232C and USB Port)
• 4.5 Inch thermal printer