Mono-Axial Accelerometer and Triaxial Accelerometer ICP mechanical vibrations Delta Ohm

Code: Delta Ohm Accelerometers


 

Datasheet PDF, 0.32 Mb

Description

Accelerometer models

HD356A02: tri-axial accelerometer for the measurement of vibrations transmitted to the handarm system; sensitivity of 10mV/g and maximum acceleration equal to 500g. This sensor is mainly used for hand-arm measurements.

 

HD356B21: miniature tri-axial accelerometer for the measurement of vibrations transmitted to the hand-arm system; sensitivity of 10mV/g and maximum acceleration equal to 500g. This sensor is mainly used for hand-arm measurements.

 

HD356B41: tri-axial accelerometer inserted in a rubber pad for the measurement of the vibrations trasnmitted to the whole body. 3m connection cable to the HD2030 analyser included. Sensitivity 100mV/g and maximum acceleration 10g.

 

HD356A22: tri-axial accelerometer for general application with sensitivity of 100mV/g and maximum acceleration equal to 50g.

 

HD352C34: mono-axial accelerometer for general application with nominal sensitivity of 100mV/g and maximum acceleration equal to 50g.

 

HD356B20: miniature tri-axial accelerometer for the measurement of vibrations transmitted to the hand-arm system at high shock level. Sensitivity of 1mV/g and maximum acceleration equal to 5000g.

 

More products SENSECA

LABORATORY BENCHTOP CONDUCTIVITY-METER-THERMOMETER WITH LIQUID RESISTIVITY, DISSOLVED SOLIDS TDS DELTA OHM HD2206.2

• Bench-top conductivity meter-Thermometer with back-lighted display,
• with inputs for measurements of conductivity, liquid resistivity, total dissolved solids (TDS) and the salinity by conductivity and temperature
• combined probes with 2 or 4 electrodes with direct input or with SICRAM module.
• Datalogger of conductivity or resistivity or TDS and temperature.
• RS232 C or USB 2.0 serial output for data download to a PC or printer from memory or in real time.
• Input for Pt100 or Pt1000 temperature probes provided with SICRAM module.

 

PORTABLE PHOTO-RADIOMETER DATALOGGER TO MEASURE NON-COHERENT OPTICAL RADIATION ACC.EUROPEAN DIRECTIVE 2006/25/EC DELTA OHM HD2402

• portable photo-radiometer data logger for the measurement of noncoherent optical radiation
• in accordance with European Directive 2006/25/EC and the Legislative Decree No 81, April 9, 2008.
• Photometric sensor for measuring the illuminance (lux meter) in the spectralrange 380÷780 nm.
• Radiometric sensor for the UV band (220÷400 nm) with spectral weighing factor S(?).
• Radiometric sensor for UVA band (315÷400 nm).
• Radiometric sensor for the band 400÷700 nm (blue) with spectral weighing factor B (?).
• Radiometric sensor for the IR band (700÷1300 nm) with spectral weighing factor R(?).
• Thermopile sensor for the measurement of irradiance in the infrared spectral range 400÷2800 nm.

 

DISSOLVED OXIGEN TESTER WITH THERMOMETER AND DATALOGGING DELTA OHM HD2109.1 HD2109.2

• Oxygen meter-Thermometer measures dissolved oxygen, saturation index and temperature.
• Datalogger which stores the maximum, minimum, average value and can store up to 18,000 samples.
• RS232 C/ USB output for data transfer in real time to a PC or printer.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree.

 

RADIOMETRIC PROBE FOR OUTDOOR MEASURING OF SOLAR IRRADIANCE DELTA OHM LP UVA02

• Radiometric probe for outdoor use for measuring IRRADIANCE in the range UVA (315...400nm).
• mV per mW/cm2 output.
• Complete with Calibration Report.
• On request 5 or 10m cables with connectors

 

MONO-AXIAL ACCELEROMETER AND TRIAXIAL ACCELEROMETER ICP MECHANICAL VIBRATIONS DELTA OHM

• HD356A02: tri-axial accelerometer for the measurement of vibrations transmitted to the handarm system
• HD356B21: miniature tri-axial accelerometer for the measurement of vibrations transmitted to the hand-arm system
• HD356B41: tri-axial accelerometer inserted in a rubber pad for the measurement of the vibrations trasnmitted to the whole body
• HD356A22: tri-axial accelerometer for general application
• HD352C34: mono-axial accelerometer for general application
• HD356B20: miniature tri-axial accelerometer for the measurement of vibrations transmitted to the hand-arm system at high shock level

 

METEO DATALOGGER WITH DATA ACQUISITION AND RECORDING DELTA OHM HD32MT.1

• 16-channel data logger capable of capturing and logging the values measured by a series of sensors connected to its inputs
• Sensors with analog voltage output, both unipolar and bipolar
• Sensors with analog current output(0..20mA, 4..20mA)
• Temperature sensors thermocouple(typpe K, J, T, N, R, S, B, E)
• Pt100/Pt1000 and NTC temperature sensors
• Sensors with digital output TTL level pulse (ON/OFF)
• Sensors with open/close contact output(e.g. rain gauges, cup anemometers

 

DATALOGGER FOR PRESSURE, TEMPERATURE, FLOW RATE DELTA OHM DO9704

• Datalogger for pressure, flow rate and temperature measurements with 2 inputs,
• memory 512 Kbytes,
• storage of maximum, minimum and average value.
• RS232 C output

 

LABORATORY BENCHTOP CONDUCTIVITY-METER-THERMOMETER WITH LIQUID RESISTIVITY, DISSOLVED SOLIDS TDS DELTA OHM HD3406.2

• Bench-top Conductivity meter-Thermometer measures conductivity, liquid resistivity,
• total dissolved solids (TDS) and salinity by 2 or 4 electrodes,
• combined conductivity probes and temperature by Pt100 or Pt1000 probes.
• Datalogger which stores maximum, minimum, average value, it can store up to 36,000 samples.
• RS232 C serial output or USB 2.0 for data download to a PC or printer from memory or in real time.
• Functions: REL, HOLD, auto power off which can be disabled.,
• protection degree IP 66

 

DATALOOGER WITH MICROCLIMATE ANALYSIS WBGT PMV PPD DELTA OHM HD32.3 HD32.3A

• Analysis of hot environments using WBGT index
• Analysis of the moderate warm environments using PMV index and PPD index
• Logging
• Start and stop can be set automatically with the auto-start function
• Selectable measurement unit of the temperature: °C, °F, °K.
• Date and time of the instrument.

 

INDOOR QUALITY ANALYSIS IAQ MONITORING DATALOGGER CO CO2 DELTA OHM HD37AB1347

• Datalogger for indoor air quality analysis (IAQ)
• measures: airspeed, temperature, relative humidity, atmospheric pressure, CO2 (Carbon Dioxide) and CO (Carbon Monoxide)
• Memory capacity of 67,600 records for each of the two inputs.
• Logging interval from 15 seconds to 1 hour.