Laboratory Tester for Electrochemical parameters: pH, conductivity, dissolved oxygen, temperature, concentration, solids, salinity Delta Ohm HD22569.2

Code: Delta Ohm HD22569.2


 

Datasheet PDF, 0.29 Mb

Description

The instrument HD22569.2 is a bench top instrument for electrochemical measures: pH, conductivity, dissolved oxygen, and temperature. It is are fitted with a large backlighted LCD display.


The HD22569.2 measures pH, mV, redox potential (ORP) with pH, redox electrodes or electrodes with separate reference; conductivity, resistivity in liquids, total dissolved solids (TDS) and salinity with combined 4-ring and 2-ring conductivity/temperature probes with direct input or SICRAM module; concentration of dissolved oxygen in liquids (in mg/l) and saturation index (in %), using SICRAM combined probes of polarographic type with two or three electrodes and integrated temperature sensor.
The instruments is fitted with an input for the measurement of temperature with Pt100 or Pt1000 immersion, penetration or contact probes. The temperature probes are equipped with an automatic recognition module and factory calibration data are stored inside.
• The pH electrode calibration can be carried out on one or five points and the calibration sequence can be chosen from a list of 13 buffers Temperature compensation can be automatic or manual.
• The conductivity probe calibration can be performed automatically with automatically detected conductivity calibration solutions: 147µS/cm, 1413µS/cm, 12880µS/cm or 111800µS/cm or manually with calibration solutions having different values.
• The dissolved Oxygen probe's quick calibration function guarantees timely correctness of the performed measurements.
• Conductivity, dissolved oxygen and temperature probes fitted with SICRAM module can store factory and calibration data inside.
The instruments HD22569.2 is a datalogger, it can memorize up to 2,000 samples of data:
• pH or mV, conductivity or resistivity or TDS or salinity, concentration of dissolved oxygen and temperature:
The data can be transferred from the instrument connected to a PC via the multi-standard RS232C serial port and USB 2.0. The storing parameters can be configured using the menu.
The RS232C serial port can be used to transfer the acquired measurements to a 24 column portable printer in real time (HD40.1 or HD40.2).
The instruments equipped with HD22BT (Bluetooth) option can transfer data without any connection to a PC or printer fitted with Bluetooth input or through Bluetooth/RS232C converter.
The software DeltaLog11 allows instrument management and configuration, and data processing on PC.
The instruments have IP66 protection degree.

 

More products SENSECA

LABORATORY BENCHTOP CONDUCTIVITY-METER-THERMOMETER WITH LIQUID RESISTIVITY, DISSOLVED SOLIDS TDS DELTA OHM HD2206.2

• Bench-top conductivity meter-Thermometer with back-lighted display,
• with inputs for measurements of conductivity, liquid resistivity, total dissolved solids (TDS) and the salinity by conductivity and temperature
• combined probes with 2 or 4 electrodes with direct input or with SICRAM module.
• Datalogger of conductivity or resistivity or TDS and temperature.
• RS232 C or USB 2.0 serial output for data download to a PC or printer from memory or in real time.
• Input for Pt100 or Pt1000 temperature probes provided with SICRAM module.

 

PORTABLE PH-METER WITH THERMOMETER DELTA OHM HD2305.0

• pHmeter-Thermometer which measures pH, mV and temperature.
• Storage of maximum, minimum, average value.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree.

 

DATALOOGER WITH MICROCLIMATE ANALYSIS WBGT DELTA OHM HD32.2 HD32.2A

• analysis of WBGT index (Wet Bulb Glob Temperature: wet bulb temperature and globe thermometer temperature) in presence or in absence of solar radiation
• Logging
• data transfer speed via the RS232 serial port
• The measurement unit of the temperature: °C, °F, °K
• Date and time of the instrument
• display of maximum, minimum, medium statistic parameters and their deletion

 

MULTIFUNCTION DATALOOGER WITH MICROCLIMATE ANALYSIS DELTA OHM HD32.1

• Globe temperature
• Natural wet bulb temperature
• Ambient temperature
• Atmospheric pressure
• Relative Humidity
• Air velocity
• Air temperature at the height of the head...

 

CONDUCTIVIMETER-THERMOMETER FOR CONDUCTIVITY, LIQUID RESISTIVITY, DISSOLVED SOLIDS, SALINITY, TEMPERATURE DELTA OHM HD2106.1 HD2106.2

• Conductivity-Thermometer measures conductivity, liquid resistivity, total dissolved solids, salinity and temperature.
• Datalogger which can store the maximum, minimum, average value and can store up to 36,000 samples.
• RS232 C/ USB output for data transfer in real time to a PC or printer.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree.

 

SECONDARY CLSSS PYRANOMETER ACCORDING TO WMO STANDARD ISO9060 DELTA OHM LP PYRA08

• Second class pyranometer according to ISO 9060,
• fast response sensor complete with calibration report,
• possibility to replace the exhausted silica-gel.
• Different configurations available.
• Male M12 connector.
• On request cables with M12 female connector: CPM12AA, length 2, 5, 10m.

 

LABORATORY BENCH PHMETER-CONDUCTIVIMETER-THERMOMETER DELTA OHM HD3456.2

• Bench-top pHmeter-Conductivity meter-Thermometer
• measures pH, mV, ORP values by pH, redox or separated reference electrodes, conductivity,
• liquids resistivity, total dissolved solids (TDS) and salinity by combined conductivity and temperature probes by Pt100 or Pt1000 probes.
• Datalogger which stores maximum, minimum, average value.
• RS232 C serial output or USB 2.0 for data download to a PC or printer from memory or in real time.
• Functions: REL, HOLD, auto power off which can be disabled,
• protection degree IP 66

 

METEO PIRGEOMETER FOR INFRARED RADIATION MEASUREMENT DELTA OHM LP PIRG01

• The pyrgeometer LP PIRG 01 is used to measure the far infrared radiation (FIR).
• Its use is mainly in the meteorological field.
• Measures are referred to radiations with wavelength greater than 4.5 µm .
• The far infrared radiation derives from the measure of the thermopile output signal and from the knowledge of the instrument temperature. The temperature measure is performed by a 10kO NTC which is inside the body of the pyrgeometer.
• The pyrgeometer can be used also for the study of energy balance

 

PORTABLE PHOTO-RADIOMETER DATALOGGER TO MEASURE NON-COHERENT OPTICAL RADIATION ACC.EUROPEAN DIRECTIVE 2006/25/EC DELTA OHM HD2402

• portable photo-radiometer data logger for the measurement of noncoherent optical radiation
• in accordance with European Directive 2006/25/EC and the Legislative Decree No 81, April 9, 2008.
• Photometric sensor for measuring the illuminance (lux meter) in the spectralrange 380÷780 nm.
• Radiometric sensor for the UV band (220÷400 nm) with spectral weighing factor S(?).
• Radiometric sensor for UVA band (315÷400 nm).
• Radiometric sensor for the band 400÷700 nm (blue) with spectral weighing factor B (?).
• Radiometric sensor for the IR band (700÷1300 nm) with spectral weighing factor R(?).
• Thermopile sensor for the measurement of irradiance in the infrared spectral range 400÷2800 nm.

 

MANOMETER THERMOMETER DIGITAL HANDHELD DELTA OHM HD2304.0

• Manometer-Thermometer with one input for SICRAM module PP471 to connect probes TP704 and TP705 series
• Temperature measurement with Pt100 probe complete with SICRAM module, measuring range 200°C +650°C.
• Storage of maximum, minimum, average value.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree.