Luxmeter Photo- Radiometer measuring Solar illuminance, PAR, irradiance Delta Ohm HD2102.1 HD2102.2

Code: Delta Ohm HD2102.1 HD2102.2


 

Datasheet PDF, 0.54 Mb

Description

Device for measuring illuminance, luminance, PAR, irradiance. Storage of maximum, minimum, average value and the integral Q(t), RS232 C output for data transfer in real time to a PC or printer. Functions: REL, HOLD and auto power off which can be disabled, IP 67 protection degree. Complete with carrying case, instruction manual, 4 batteries, Software DeltaLog 9. LP471.. series probes with SICRAM module are suitable. The probes and cables for data download have to be ordered separately
 

More products SENSECA

DATALOGGER PHOTO-RADIOMETER FOR SOLAR LIGHT, TEMPERATURE DELTA OHM DO9721

• Datalogger Photo-radiometer Thermometer which performs photometric, radiometric, PAR, temperature measurements.
• Two inputs.
• Function as datalogger: 30,000 samples, REL, Record, Q (integration),
• RS232C serial output

 

SOUND LEVEL CALIBRATOR WITH AUDIO SIGNAL GENERATOR FOR ACOUSTIC CALIBRATIONS CLASS I/II DELTA OHM HD9101 HD9102

• generator noise level 9101/HD HD 9102
• portable, battery-powered sound source,
• suitable for calibration of sound level meters (portable and laboratory) and acoustic measuring stations
• possible to calibrate directly microphones 1 / 2 "of mechanical dimensions conform to the requirements of IEC 61094-1
• the frequency of the sound signal at 1000Hz can perform calibration of sound level meters with any frequency weighting
• sound pressure level generated is independent of atmospheric pressure
• Ease of use allows the use even by unskilled personnel.

 

RAIN DETECTOR AND ATHMOSPHERICAL PRECIPITATION DELTA OHM HD2013.2

• rain detector based on the capacity principle
• The instrument is equipped with three different outputs: a "Rain ON/OFF" output
• detects whether it is raining/ snowing (ON) or not (OFF), also used to control a relay coil or similar devices
• can be used either as a separate device, or connected to a data logger system

 

LUXMETER PHOTO- RADIOMETER MEASURING SOLAR ILLUMINANCE, PAR, IRRADIANCE DELTA OHM HD2102.1 HD2102.2

• Device for measuring illuminance, luminance, PAR, irradiance.
• Storage of maximum, minimum, average value and the integral Q(t),
• RS232 C output for data transfer in real time to a PC or printer.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree

 

HANDHELD DIGITAL THERMOCOUPLE THERMOMETER K, J, T, R, N, S, B, E DELTA OHM HD2108.1 HD2108.2 HD2128.1 HD2128.2

• Thermocouple thermometer with one input and logger 32.000 samples
• For K, J, T, R, N, S, B, E type probes with miniature connector
• Storage of maximum, minimum, average value,
• USB/RS232 C connection to download loggerdata to PC.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree

 

INTEGRATING SOUND LEVEL METER CLASS I / CLASS II WITH DATALOGGING, SPECTRAL ANALYSIS & STATISTICS DELTA OHM HD2010UC/A

• portable integrating class 1 sound level meter, with data logging function, suitable for performing statistical and spectral analyses
• possibility of adjusting the instrument and adding options at any time
• user can upgrade the firmware directly by means of the Noise Studio programme supplied with the instrument
• Class 1 or 2 sound level meter according to IEC 61672-1 IEC 60651 and IEC 60804
• Class 1 octave and third octave filters according to IEC 61260
• Assessment of the environmental noise level,
• Noise monitoring and optional capture and analysis of sound events,
• Octave and optional third octave band spectrum analysis from 25 Hz to 12.5 kHz,

 

MANOMETER THERMOMETER DIGITAL HANDHELD DELTA OHM HD2304.0

• Manometer-Thermometer with one input for SICRAM module PP471 to connect probes TP704 and TP705 series
• Temperature measurement with Pt100 probe complete with SICRAM module, measuring range 200°C +650°C.
• Storage of maximum, minimum, average value.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree.

 

LABORATORY ELECTROCHEMICAL MULTIPARATEMER TESTER FOR DISSLVED OXIGEN, CONCENTRATION, SATURATION INDEX DELTA OHM HD3409.2

• Bench-top Oxymeter-Thermometer measures dissolved oxygen,
• saturation index by polarographic type combined probes,
• temperature by Pt100 probes with SICRAM module.
• Datalogger which stores maximum, minimum, average value.
• RS232 C serial output or USB 2.0 for data download to a PC or printer from memory or in real time.
• Functions: REL, HOLD, auto power off which can be disabled,
• protection degree IP 66

 

PORTABLE PHOTO-RADIOMETER DATALOGGER TO MEASURE NON-COHERENT OPTICAL RADIATION ACC.EUROPEAN DIRECTIVE 2006/25/EC DELTA OHM HD2402

• portable photo-radiometer data logger for the measurement of noncoherent optical radiation
• in accordance with European Directive 2006/25/EC and the Legislative Decree No 81, April 9, 2008.
• Photometric sensor for measuring the illuminance (lux meter) in the spectralrange 380÷780 nm.
• Radiometric sensor for the UV band (220÷400 nm) with spectral weighing factor S(?).
• Radiometric sensor for UVA band (315÷400 nm).
• Radiometric sensor for the band 400÷700 nm (blue) with spectral weighing factor B (?).
• Radiometric sensor for the IR band (700÷1300 nm) with spectral weighing factor R(?).
• Thermopile sensor for the measurement of irradiance in the infrared spectral range 400÷2800 nm.

 

PORTABLE PH-METER WITH THERMOMETER AND DATALOGGING DELTA OHM HD2105.1 HD2105.2

• pHmeter-Thermometer which measures pH, mV and temperature.
• Datalogger which stores the maximum, minimum, average value and can store up to 34,000 samples.
• RS232 C/ USB output for data transfer in real time to a PC or printer.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree.