8-16 Channel Temperature Datalogger Delta Ohm HD32.7 HD32.8.8 HD32.8.16

Code: Delta Ohm HD32.7 HD32.8.8 HD32.8.16


 

Datasheet PDF, 0.44 Mb

Description

HD32.7 - 8 INPUTS DATA LOGGER FOR pt100 SENSOR PROBES
The instrument HD32.7 is a robust 8 inputs data logger for Pt100 sensor temperature probes equipped with SICRAM module. 4 wires Pt100 Probe.
• Unit of measurement °C, °F, °K configurable.
• Flash memory organized in 64 sections with a total capacity of 96.000 acquisitions for each one of the 8 inputs. Storage can be managed in two ways:
- when the available memory is full, data are overwritten by starting from the oldest ones (circular memory),
- storage stops when the available memory is full.
• Simultaneous display of the 8 inputs.
• Maximum, minimum or average of the stored values.
• Selectable storage interval: 2, 5, 10, 15, 30 seconds, 1, 2, 5, 10, 15, 20, 30 minutes and 1 hour.
• Data logging: instantaneous or postponed, with the possibility of selecting the storage start and end.
• Data download: RS232C, 1200...38400 baud or USB 1.1 - 2.0.
• DeltaLog9 software for data download and processing.
• LCD backlit graphic display 128x64 pixel.
• Instrument setup through the keyboard; no connection required to the PC.
• Security password for keyboard locking.
• Power supply: 4 1.5V alkaline C-BABY type batteries or external power supply 12VDC-1A.
• Consumption @6VDC:
<60µA when the instrument is off
<60µA in sleep mode with 8 probes connected
<40mA during data logging with 8 probes connected
• Use of the HD32.7 data logger: in the field for machine or equipment measurements,
plant or machine testing, production check, oven mapping.

 

HD32.8.8/ HD32.8.16 Rugged data logger with 8/16 inputs for K, J, T, N, R, S, B and E type thermocouple with miniature connector temperature probes.
• Unit of measurement °C, °F, °K configurable.
• Flash memory organized in 64 sections with a total capacity of 800.000 acquisitions to be divided among all the present inputs. Storage can be managed in two ways:
- when the available memory is full, data are overwritten by starting from the oldest ones (circular memory),
- storage stops when the available memory is full
• Simultaneous display of the 8 inputs.
• Maximum, minimum or average of the stored values.
• Selectable storage interval: 2, 5, 10, 15, 30 seconds, 1, 2, 5, 10, 15, 20, 30 minutes and 1 hour.
• Data logging: instantaneous or postponed, with the possibility of selecting the storage start and end.
• Data download: RS232C, 1200...38400 baud or USB 1.1 - 2.0.
• DeltaLog9 software for data download and processing.
• LCD backlit graphic display 128x64 pixel.
• Instrument setup through the keyboard; no connection required to the PC.
• Security password for keyboard locking.
• Power supply: 4 1.5V alkaline C-BABY type batteries, or external power supply 12VDC-1A or by means of the USB port of the PC.
• Consumption @6VDC:
<60µA when the instrument is off
<60µA in sleep mode with 8 probes connected
<40mA during data logging with 8 probes connected
• Use of data loggers HD32.8.8 and HD32.8.16: in field for measurement campaigns on complex systems with many measurement points, testing facilities, in pharmaceutical and food sectors, ovens mapping, air conditioning centrals etc.

 

More products SENSECA

LABORATORY BENCH PHMETER-CONDUCTIVIMETER-THERMOMETER DELTA OHM HD3456.2

• Bench-top pHmeter-Conductivity meter-Thermometer
• measures pH, mV, ORP values by pH, redox or separated reference electrodes, conductivity,
• liquids resistivity, total dissolved solids (TDS) and salinity by combined conductivity and temperature probes by Pt100 or Pt1000 probes.
• Datalogger which stores maximum, minimum, average value.
• RS232 C serial output or USB 2.0 for data download to a PC or printer from memory or in real time.
• Functions: REL, HOLD, auto power off which can be disabled,
• protection degree IP 66

 

LABORATORY BENCH PHMETER-CONDUCTIVIMETER-THERMOMETER DELTA OHM HD2256.2

• Bench-top pHmeter-Conductivity meter-Thermometer with back-lighted display,
• to measure pH, mV, ORP by pH, redox, separated reference electrodes, one input for a pH/temperature combined probe,
• it measures conductivity, liquid resistivity, total dissolved solids (TDS) and salinity by combined conductivity and temperature probes with
• 2 or 4 electrodes with direct input or with SICRAM module.
• Datalogger for pH or mV, conductivity or resistivity or TDS and temperature.
• RS232 C serial output or USB 2.0 for data download to a PC or printer from memory or in real time.

 

MICRO MANOMETER-THERMOMETER DELTA OHM HD2114P HD2134P

• Micromanometer-Thermometer for air speed and flow rate measurement by means of Pitot tubes
• full scale 20mbar for speed measurements from 2...55m/s.
• Temperature measurement by K type thermocouple.
• Datalogger which stores the maximum, minimum, average value and can store up to 36,000 couples of samples.
• RS232C/ USB output for data transfer in real time to a PC or printer

 

THERMO HYGROMETER DELTA OHM HD2301.0

• Thermo hygrometer, instrument measuring range for temperature -200°C +650°C with probe TP47...
• humidity 0.0...100.0%RH
• Storage of maximum, minimum, average value.
• Functions: REL, HOLD and auto power off which can be disabled
• IP 67 protection degree

 

NET RADIOMETER WITH 4-COMPONENTS FOR SOLAR RADIATION MEASUREMENTS DELTA OHM LP NET14

• LP NET 14 is a 4-component net-radiometer for the measurement of the net radiation between 0.3µm and 45 µm.
• consists of two pyranometers: one for the measurement of the global radiation Esw? and the other one for the measurement of the reflected solar radiation Esw?
• pair of pyrgeometers: one for the measurement of the infrared radiation emitted by the sky EFIR? and the other one for the infrared emitted by the ground surface EFIR?
• equipped with a temperature sensor (NTC).

 

DUAL INPUT THERMOMETER DELTA OHM HD2178.1 HD2178.2

• Thermometer with two inputs, the first for Pt100 probes equipped with SICRAM module, the second input for thermocouple type K, J, T, E, N
• large display
• Storage of maximum, minimum, average value
• RS232 C output for data transfer in real time to a PC or printer
• Functions: REL, HOLD and auto power off which can be disabled
• IP 67 protection degree

 

TWO-AXIS ULTRASONIC ANEMOMETER FOR WINDSPEED & WINDDIRECTION MEASUREMENT DELTA OHM HD52.3

• 2 axes ultrasonic Anemometers series HD 52.3D
• Wind speed and direction, U-V Cartesian components of wind speed,
• Relative Humidity and Temperature (option, code "17"),
• Diffuse Solar Radiation (option, code "P"),
• Barometric pressure (option, code "4").

 

SILICON PHOTODIODE PYRANOMETER WITH GLOBAL SOLAR RADIATION MEASUREMENT FOR PHOTOVOLTAIC PANELS DELTA OHM LP SILICON-PYRA04

• LP Silicon-PYRA 04. pyranometer
• measures the global solar radiation (W/m2) by using a silicon photodiode (400nm-1100nm).
• special geometry and the diffuser allow to have a pyranometer field of view of 180 degrees according to cosine law.
• The pyranometer is suitable for the measurement of natural sunlight.

 

MULTIPARAMETRIC PH-METER-CONDUCTIVIMETER-THERMOMETER DELTA OHM HD2156.1 HD2156.2

• pHmeter-Conductivity-Thermometer measures pH, mV, conductivity, liquid resistivity, total dissolved solids, salinity and temperature.
• Datalogger, stores the maximum, minimum, average value and can store up to 20,000 sets of three measurements.
• USB output for data transfer in real time to a PC or printer.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree.

 

LABORATORY ELECTROCHEMICAL MULTIPARATEMER TESTER FOR DISSLVED OXIGEN, CONCENTRATION, SATURATION INDEX DELTA OHM HD3409.2

• Bench-top Oxymeter-Thermometer measures dissolved oxygen,
• saturation index by polarographic type combined probes,
• temperature by Pt100 probes with SICRAM module.
• Datalogger which stores maximum, minimum, average value.
• RS232 C serial output or USB 2.0 for data download to a PC or printer from memory or in real time.
• Functions: REL, HOLD, auto power off which can be disabled,
• protection degree IP 66