Description

HD32.7 - 8 INPUTS DATA LOGGER FOR pt100 SENSOR PROBES
The instrument HD32.7 is a robust 8 inputs data logger for Pt100 sensor temperature probes equipped with SICRAM module. 4 wires Pt100 Probe.
• Unit of measurement °C, °F, °K configurable.
• Flash memory organized in 64 sections with a total capacity of 96.000 acquisitions for each one of the 8 inputs. Storage can be managed in two ways:
- when the available memory is full, data are overwritten by starting from the oldest ones (circular memory),
- storage stops when the available memory is full.
• Simultaneous display of the 8 inputs.
• Maximum, minimum or average of the stored values.
• Selectable storage interval: 2, 5, 10, 15, 30 seconds, 1, 2, 5, 10, 15, 20, 30 minutes and 1 hour.
• Data logging: instantaneous or postponed, with the possibility of selecting the storage start and end.
• Data download: RS232C, 1200...38400 baud or USB 1.1 - 2.0.
• DeltaLog9 software for data download and processing.
• LCD backlit graphic display 128x64 pixel.
• Instrument setup through the keyboard; no connection required to the PC.
• Security password for keyboard locking.
• Power supply: 4 1.5V alkaline C-BABY type batteries or external power supply 12VDC-1A.
• Consumption @6VDC:
<60µA when the instrument is off
<60µA in sleep mode with 8 probes connected
<40mA during data logging with 8 probes connected
• Use of the HD32.7 data logger: in the field for machine or equipment measurements,
plant or machine testing, production check, oven mapping.

 

HD32.8.8/ HD32.8.16 Rugged data logger with 8/16 inputs for K, J, T, N, R, S, B and E type thermocouple with miniature connector temperature probes.
• Unit of measurement °C, °F, °K configurable.
• Flash memory organized in 64 sections with a total capacity of 800.000 acquisitions to be divided among all the present inputs. Storage can be managed in two ways:
- when the available memory is full, data are overwritten by starting from the oldest ones (circular memory),
- storage stops when the available memory is full
• Simultaneous display of the 8 inputs.
• Maximum, minimum or average of the stored values.
• Selectable storage interval: 2, 5, 10, 15, 30 seconds, 1, 2, 5, 10, 15, 20, 30 minutes and 1 hour.
• Data logging: instantaneous or postponed, with the possibility of selecting the storage start and end.
• Data download: RS232C, 1200...38400 baud or USB 1.1 - 2.0.
• DeltaLog9 software for data download and processing.
• LCD backlit graphic display 128x64 pixel.
• Instrument setup through the keyboard; no connection required to the PC.
• Security password for keyboard locking.
• Power supply: 4 1.5V alkaline C-BABY type batteries, or external power supply 12VDC-1A or by means of the USB port of the PC.
• Consumption @6VDC:
<60µA when the instrument is off
<60µA in sleep mode with 8 probes connected
<40mA during data logging with 8 probes connected
• Use of data loggers HD32.8.8 and HD32.8.16: in field for measurement campaigns on complex systems with many measurement points, testing facilities, in pharmaceutical and food sectors, ovens mapping, air conditioning centrals etc.

 

More products SENSECA

THERMOPILE PYRANOMETER FOR MEASURE INCOMING GLOBAL SOLAR RADIATION DELTA OHM LP PYRA02 PYRA03 PYRA12

• First class pyranometer according to ISO 9060.
• Complete with: shade disk, sachet with silica-gel crystals, 2 cartridges, levelling device and calibration report.
• On request 5 or 10m cables with connectors

 

LABORATORY TESTER FOR ELECTROCHEMICAL PARAMETERS: PH, CONDUCTIVITY, DISSOLVED OXYGEN, TEMPERATURE, CONCENTRATION, SOLIDS, SALINITY DELTA OHM HD22569.2

• bench top instrument for electrochemical measures: pH, conductivity, dissolved oxygen, and temperature.
• It is are fitted with a large backlighted LCD display.
• pH, mV, redox potential (ORP) with pH, redox electrodes or electrodes with separate reference;
• conductivity, resistivity in liquids,
• total dissolved solids (TDS) and salinity with combined 4-ring and 2-ring conductivity/
• temperature probes with direct input or SICRAM module;
• concentration of dissolved oxygen in liquids (in mg/l) and saturation index (in %),

 

LABORATORY BENCH PHMETER-CONDUCTIVIMETER-THERMOMETER DELTA OHM HD3456.2

• Bench-top pHmeter-Conductivity meter-Thermometer
• measures pH, mV, ORP values by pH, redox or separated reference electrodes, conductivity,
• liquids resistivity, total dissolved solids (TDS) and salinity by combined conductivity and temperature probes by Pt100 or Pt1000 probes.
• Datalogger which stores maximum, minimum, average value.
• RS232 C serial output or USB 2.0 for data download to a PC or printer from memory or in real time.
• Functions: REL, HOLD, auto power off which can be disabled,
• protection degree IP 66

 

SILICON PHOTODIODE PYRANOMETER WITH GLOBAL SOLAR RADIATION MEASUREMENT FOR PHOTOVOLTAIC PANELS DELTA OHM LP SILICON-PYRA04

• LP Silicon-PYRA 04. pyranometer
• measures the global solar radiation (W/m2) by using a silicon photodiode (400nm-1100nm).
• special geometry and the diffuser allow to have a pyranometer field of view of 180 degrees according to cosine law.
• The pyranometer is suitable for the measurement of natural sunlight.

 

AIR QUALITY ANALYSIS MONITORING DATALOGGER CO CO2 DELTA OHM HD37AB17D HD37B17D

• data loggers able to measure and memorize simultaneously the following parameters:
• Relative Humidity RH
• Environment temperature T
• Carbon monoxide CO (only HD37AB17D)
• Carbon dioxide CO2
• DeltaLog13 communication software via the USB port

 

SOUND LEVEL CALIBRATOR FOR MICROPHONES AND ACOUSTIC STATIONS DELTA OHM HD2020

• HD 2020 sound level calibrator
• portable, battery operated sound source
• suitable for sound level meters (portable and laboratory) and acoustic stations
• class 1 according to IEC60942:2003 with LCD display.
• ISO 9001 calibration report included.
• 1000Hz frequency allows calibrating sound level meters with any weighting

 

ALBEDOMETER PYRANOMETER FOR GLOBAL INCIDENT SOLAR RADIATION DELTA OHM LPPYRA05

• Albedometer First and Second Class pyranometers according to ISO 9060.
• Complete with: upper and bottom shade disk, desiccant sachet with silica-gel crystals, 2 cartridges, levelling device, support bracket
• calibration report.
• On request 5 or 10m cables with connectors.

 

METEO DATALOGGER WITH DATA ACQUISITION AND RECORDING DELTA OHM HD32MT.1

• 16-channel data logger capable of capturing and logging the values measured by a series of sensors connected to its inputs
• Sensors with analog voltage output, both unipolar and bipolar
• Sensors with analog current output(0..20mA, 4..20mA)
• Temperature sensors thermocouple(typpe K, J, T, N, R, S, B, E)
• Pt100/Pt1000 and NTC temperature sensors
• Sensors with digital output TTL level pulse (ON/OFF)
• Sensors with open/close contact output(e.g. rain gauges, cup anemometers

 

MONO-AXIAL ACCELEROMETER AND TRIAXIAL ACCELEROMETER ICP MECHANICAL VIBRATIONS DELTA OHM

• HD356A02: tri-axial accelerometer for the measurement of vibrations transmitted to the handarm system
• HD356B21: miniature tri-axial accelerometer for the measurement of vibrations transmitted to the hand-arm system
• HD356B41: tri-axial accelerometer inserted in a rubber pad for the measurement of the vibrations trasnmitted to the whole body
• HD356A22: tri-axial accelerometer for general application
• HD352C34: mono-axial accelerometer for general application
• HD356B20: miniature tri-axial accelerometer for the measurement of vibrations transmitted to the hand-arm system at high shock level

 

MANOMETER-THERMOMETER DIGITAL HANDHELD DELTA OHM HD2124.1 HD2124.2

• Manometer-Thermometer with two inputs for SICRAM module PP471 to connect probes TP704 and TP705 series.
• Temperature measurement with Pt100 probe complete with SICRAM module measuring range 200°C +650°C.
• Datalogger which stores the maximum, minimum, average value and can store up to 32,000 couples of samples.
• RS232 C/ USB output for data transfer in real time to a PC or printer.
• Functions: REL, HOLD, PEAK and auto power off which can be disabled,
• IP 67 protection degree.