Sound Level Calibrator for Microphones and Acoustic Stations Delta Ohm HD2020

Code: Delta Ohm HD2020


 

Datasheet PDF, 1.09 Mb
 

Description

The HD 2020 sound level calibrator is a portable, battery operated sound source, suitable for sound level meters (portable and laboratory) and acoustic stations. It allows calibrating ½" microphones with mechanical dimensions compliant with IEC 61094-1 ("Measurement microphones. Part 1: Specifications for laboratory standard microphones") and IEC 61094-4 ("Measurement microphones. Part 4: Specifications for working standard microphones"). The calibration pressure levels of 94dB and 114dB can be selected by the keypad. The 1000 Hz frequency cannot be changed.
If the microphone is absent or not inserted correctly into the calibrator cavity, the sound level will blink on the display.
To conserve battery life, the instrument is provided with an automatic power off function: if you leave the instrument on with open cavity, it switches off automatically after 30 seconds. If the cavity is closed and the microphone is inserted, the instrument switches off 5 minutes after turning on, provided that you don't press any key.
The calibrator display shows calibration pressure level, battery life, current date and time.

 

Sound level calibrator class 1 according to IEC60942:2003 with LCD display. ISO 9001 calibration report included.

Advantages of the HD 2020 Sound level calibrator are:
• The 1000Hz frequency allows calibrating sound level meters with any weighting (LIN, A, B,...), without applying any correction factor.
• The calibration sound pressure level is independent of atmospheric pressure: you don't need to adjust the value according to static pressure over a wide range of values.
• The HD 2020 calibrator can be conveniently used both in laboratory and in the field. The 114 dB sound level allows performing calibrations even in high background noise environments.
• Its simplicity of use allows the use even by unskilled personnel.
• The presence of the LCD helps you through the steps of setting the calibrator, signal the end of the span and allows you to check the status of the battery.

 

 

ACOUSTIC CALIBRATOR
1. ON-OFF key: turns on and off the instrument. When you turn the instrument on, the display will switch on about three seconds later.
2. SETUP key: allows you to enter and scroll menu. To exit, press it repeatedly until you go back to the standard screen.
3. Display. When you turn the instrument on, it shows all segments on, and then the sound pressure level (94 or 114dB) will appear in standard view.
4. Calibrator cavity for conventional ½ inch microphones.
5. Down: in standard mode, it selects 94dB and 114dB pressure levels alternately. In menu mode, it decreases the current value.
6. Up: in standard mode, it selects 94dB and 114dB pressure levels alternately. In menu mode, it increases the current value.
7. Battery lid.

 

 

More products SENSECA

THERMO HYGROMETER DELTA OHM HD2301.0

• Thermo hygrometer, instrument measuring range for temperature -200°C +650°C with probe TP47...
• humidity 0.0...100.0%RH
• Storage of maximum, minimum, average value.
• Functions: REL, HOLD and auto power off which can be disabled
• IP 67 protection degree

 

PORTABLE PH-METER WITH THERMOMETER AND DATALOGGING DELTA OHM HD2105.1 HD2105.2

• pHmeter-Thermometer which measures pH, mV and temperature.
• Datalogger which stores the maximum, minimum, average value and can store up to 34,000 samples.
• RS232 C/ USB output for data transfer in real time to a PC or printer.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree.

 

HANDHELD DIGITAL THERMOCOUPLE THERMOMETER K, J, T, R, N, S, B, E DELTA OHM HD2108.1 HD2108.2 HD2128.1 HD2128.2

• Thermocouple thermometer with one input and logger 32.000 samples
• For K, J, T, R, N, S, B, E type probes with miniature connector
• Storage of maximum, minimum, average value,
• USB/RS232 C connection to download loggerdata to PC.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree

 

PORTABLE CLASS I INTEGRATING SOUND LEVEL METER WITH SPECTRUM ANALYSIS ANS STATISTICS DELTA OHM HD2010

• precision integrating portable sound level meter
• data logging functions
• performing both spectrum and statistical analysis
• maximum flexibility and simplicity
• firmware can be directly updated by the user by means of the Noise Studio program supplied with the instrument
• Class 1 sound level meter according to IEC 61672-1, 2002
• Class 1 octave and third octave filters according to IEC 61260
• Microphone complying with IEC 61094-4
• Noise monitoring and optional capture and analysis of sound events
• Octave and optional third octave band spectrum analysis from 16 Hz to 20 kHz

 

LABORATORY BENCHTOP CONDUCTIVITY-METER-THERMOMETER WITH LIQUID RESISTIVITY, DISSOLVED SOLIDS TDS DELTA OHM HD3406.2

• Bench-top Conductivity meter-Thermometer measures conductivity, liquid resistivity,
• total dissolved solids (TDS) and salinity by 2 or 4 electrodes,
• combined conductivity probes and temperature by Pt100 or Pt1000 probes.
• Datalogger which stores maximum, minimum, average value, it can store up to 36,000 samples.
• RS232 C serial output or USB 2.0 for data download to a PC or printer from memory or in real time.
• Functions: REL, HOLD, auto power off which can be disabled.,
• protection degree IP 66

 

PH AND MV-METER SIMULATOR CALIBRATING KIT DELTA OHM HD9609

• pH/mV simulator kit composed of instrument HD9609,
• adapter cables CP 9509/T,
• CP9509/BNC and
• carrying case.

 

LOGGING INSTRUMENT FOR CO, CO2, ATMOSPHERIC PRESSURE, TEMPERATURE, HUMIDITY DELTA OHM HD21AB HD21AB17

• Carbon Dioxide CO2
• Carbon Monoxide CO
• Atmospheric Pressure
• Temperature
• Relative Humidity
• Dew Point, Wet Bulb Temperature, Absolute Humidity, Mixing Ratio, Enthalpy

 

3-CHANNEL MULTIFUNCTION AIR PARAMETERS MONITORING DATALOGGER DELTA OHM DO9847

• Multifunctional handheld board instrument and datalogger
• RH, temperature, pressure, airspeed, light, voltage, current
• 128x64 pixel (56x38 mm) graphic display and three independent inputs
• Functions: watch, hold, max., min., average, record, immediate or deferred start record logging, difference between the two inputs, relative measures
• Storage capacity: 32.000 readings per input.
• RS232C serial output: from 300 up to 115.200 baud rate.

 

METEO PIRGEOMETER FOR INFRARED RADIATION MEASUREMENT DELTA OHM LP PIRG01

• The pyrgeometer LP PIRG 01 is used to measure the far infrared radiation (FIR).
• Its use is mainly in the meteorological field.
• Measures are referred to radiations with wavelength greater than 4.5 µm .
• The far infrared radiation derives from the measure of the thermopile output signal and from the knowledge of the instrument temperature. The temperature measure is performed by a 10kO NTC which is inside the body of the pyrgeometer.
• The pyrgeometer can be used also for the study of energy balance

 

ALBEDOMETER PYRANOMETER FOR GLOBAL INCIDENT SOLAR RADIATION DELTA OHM LPPYRA05

• Albedometer First and Second Class pyranometers according to ISO 9060.
• Complete with: upper and bottom shade disk, desiccant sachet with silica-gel crystals, 2 cartridges, levelling device, support bracket
• calibration report.
• On request 5 or 10m cables with connectors.