Manometer-Thermometer digital handheld Delta Ohm HD2124.1 HD2124.2

Code: Delta Ohm HD2124.1 HD2124.2


 

Datasheet PDF, 0.23 Mb

Description

Manometer-Thermometer with two inputs for SICRAM module PP471 to connect probes TP704 and TP705 series.

Temperature measurement with Pt100 probe complete with SICRAM module measuring range 200°C +650°C.

Datalogger which stores the maximum, minimum, average value and can store up to 32,000 couples of samples.

RS232 C/ USB output for data transfer in real time to a PC or printer.

Functions: REL, HOLD, PEAK and auto power off which can be disabled,

IP 67 protection degree.

Complete with carrying case, instruction manual, 4 batteries, Software DeltaLog 9. The SICRAM module PP471, pressure probes, temperature probes and cables for downloading have to be ordered separately. TP704 and TP705 series pressure probes and TP47... series temperature probes are suitable.

 

More products SENSECA

DATALOOGER WITH MICROCLIMATE ANALYSIS WBGT PMV PPD DELTA OHM HD32.3 HD32.3A

• Analysis of hot environments using WBGT index
• Analysis of the moderate warm environments using PMV index and PPD index
• Logging
• Start and stop can be set automatically with the auto-start function
• Selectable measurement unit of the temperature: °C, °F, °K.
• Date and time of the instrument.

 

PORTABLE PH-METER WITH THERMOMETER AND DATALOGGING DELTA OHM HD2105.1 HD2105.2

• pHmeter-Thermometer which measures pH, mV and temperature.
• Datalogger which stores the maximum, minimum, average value and can store up to 34,000 samples.
• RS232 C/ USB output for data transfer in real time to a PC or printer.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree.

 

MANOMETERS-THERMOMETERS DELTA OHM HD2114 HD2134 HD2164

• portable instruments with a large LCD display
• They measure absolute, relative and differential pressure, as well as temperature
• Max, Min and Avg function calculates the maximum, minimum or average values
• relative measurement REL, the HOLD function, and the automatic turning off
• store up to 36,000 samples
• standard RS232C serial port and USB 2.0

 

PORTABLE PH-METER WITH THERMOMETER DELTA OHM HD2305.0

• pHmeter-Thermometer which measures pH, mV and temperature.
• Storage of maximum, minimum, average value.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree.

 

AIR QUALITY ANALYSIS MONITORING DATALOGGER CO CO2 DELTA OHM HD37AB17D HD37B17D

• data loggers able to measure and memorize simultaneously the following parameters:
• Relative Humidity RH
• Environment temperature T
• Carbon monoxide CO (only HD37AB17D)
• Carbon dioxide CO2
• DeltaLog13 communication software via the USB port

 

THERMO HYGROMETER DELTA OHM HD2101.1 HD2101.2

• Thermo hygrometer, instrument measuring range for temperature -200°C +650°C with probe TP47...
• humidity 0.0...100.0%RH
• Storage of maximum, minimum, average value
• RS232 C output for data transfer in real time to a PC or printer
• Functions: REL, HOLD and auto power off which can be disabled
• IP 67 protection degree

 

SECONDARY CLSSS PYRANOMETER ACCORDING TO WMO STANDARD ISO9060 DELTA OHM LP PYRA08

• Second class pyranometer according to ISO 9060,
• fast response sensor complete with calibration report,
• possibility to replace the exhausted silica-gel.
• Different configurations available.
• Male M12 connector.
• On request cables with M12 female connector: CPM12AA, length 2, 5, 10m.

 

DUAL INPUT THERMOMETER DELTA OHM HD2178.1 HD2178.2

• Thermometer with two inputs, the first for Pt100 probes equipped with SICRAM module, the second input for thermocouple type K, J, T, E, N
• large display
• Storage of maximum, minimum, average value
• RS232 C output for data transfer in real time to a PC or printer
• Functions: REL, HOLD and auto power off which can be disabled
• IP 67 protection degree

 

LABORATORY BENCHTOP CONDUCTIVITY-METER-THERMOMETER WITH LIQUID RESISTIVITY, DISSOLVED SOLIDS TDS DELTA OHM HD3406.2

• Bench-top Conductivity meter-Thermometer measures conductivity, liquid resistivity,
• total dissolved solids (TDS) and salinity by 2 or 4 electrodes,
• combined conductivity probes and temperature by Pt100 or Pt1000 probes.
• Datalogger which stores maximum, minimum, average value, it can store up to 36,000 samples.
• RS232 C serial output or USB 2.0 for data download to a PC or printer from memory or in real time.
• Functions: REL, HOLD, auto power off which can be disabled.,
• protection degree IP 66

 

CENTESIMAL THERMOMETER DELTA OHM HD2107.1 HD2107.2 HD2127.1 HD2127.2

• Centesimal thermometer in the range +/-199.99°C, decimal outside this range
• one input for Pt100 probes with SICRAM module measuring range -200°C +650°C
• Storage of maximum, minimum, average value
• RS232 C output for data transfer in real time to a PC or printer
• Functions: REL, HOLD and auto power