Manometer-Thermometer digital handheld Delta Ohm HD2124.1 HD2124.2

Code: Delta Ohm HD2124.1 HD2124.2


 

Datasheet PDF, 0.23 Mb

Description

Manometer-Thermometer with two inputs for SICRAM module PP471 to connect probes TP704 and TP705 series.

Temperature measurement with Pt100 probe complete with SICRAM module measuring range 200°C +650°C.

Datalogger which stores the maximum, minimum, average value and can store up to 32,000 couples of samples.

RS232 C/ USB output for data transfer in real time to a PC or printer.

Functions: REL, HOLD, PEAK and auto power off which can be disabled,

IP 67 protection degree.

Complete with carrying case, instruction manual, 4 batteries, Software DeltaLog 9. The SICRAM module PP471, pressure probes, temperature probes and cables for downloading have to be ordered separately. TP704 and TP705 series pressure probes and TP47... series temperature probes are suitable.

 

More products SENSECA

MULTIFUNCTION DATALOOGER WITH MICROCLIMATE ANALYSIS DELTA OHM HD32.1

• Globe temperature
• Natural wet bulb temperature
• Ambient temperature
• Atmospheric pressure
• Relative Humidity
• Air velocity
• Air temperature at the height of the head...

 

METEO PIRGEOMETER FOR INFRARED RADIATION MEASUREMENT DELTA OHM LP PIRG01

• The pyrgeometer LP PIRG 01 is used to measure the far infrared radiation (FIR).
• Its use is mainly in the meteorological field.
• Measures are referred to radiations with wavelength greater than 4.5 µm .
• The far infrared radiation derives from the measure of the thermopile output signal and from the knowledge of the instrument temperature. The temperature measure is performed by a 10kO NTC which is inside the body of the pyrgeometer.
• The pyrgeometer can be used also for the study of energy balance

 

THERMO HYGROMETER DELTA OHM HD2101.1 HD2101.2

• Thermo hygrometer, instrument measuring range for temperature -200°C +650°C with probe TP47...
• humidity 0.0...100.0%RH
• Storage of maximum, minimum, average value
• RS232 C output for data transfer in real time to a PC or printer
• Functions: REL, HOLD and auto power off which can be disabled
• IP 67 protection degree

 

PORTABLE LABORATORY TURBIDITY-METER FOR LPROCESS IQUIDS, DRINKING WATER, WASTE WATER DELTA OHM HD25.2

• Portable and bench turbidity meter equipped with 3 photodetectors and two light sources
• it measures according to the standard EPA 180.1, ISO-NEPH (ISO 7027), EBC and ASBC.
• Automatic calibration,
• datalogger,
• data downloading to PC by RS232C or USB 2.0 through the software DeltaLog11

 

CENTESIMAL THERMOMETER DELTA OHM HD2107.1 HD2107.2 HD2127.1 HD2127.2

• Centesimal thermometer in the range +/-199.99°C, decimal outside this range
• one input for Pt100 probes with SICRAM module measuring range -200°C +650°C
• Storage of maximum, minimum, average value
• RS232 C output for data transfer in real time to a PC or printer
• Functions: REL, HOLD and auto power

 

SOUND LEVEL CALIBRATOR WITH AUDIO SIGNAL GENERATOR FOR ACOUSTIC CALIBRATIONS CLASS I/II DELTA OHM HD9101 HD9102

• generator noise level 9101/HD HD 9102
• portable, battery-powered sound source,
• suitable for calibration of sound level meters (portable and laboratory) and acoustic measuring stations
• possible to calibrate directly microphones 1 / 2 "of mechanical dimensions conform to the requirements of IEC 61094-1
• the frequency of the sound signal at 1000Hz can perform calibration of sound level meters with any frequency weighting
• sound pressure level generated is independent of atmospheric pressure
• Ease of use allows the use even by unskilled personnel.

 

LUXMETER RADIOMETER MEASURING ILLUMINANCE, PAR, IRRADIANCE DELTA OHM HD2302.0 HD2302.0VP474

• Device for measuring illuminance, luminance, PAR, irradiance
• Storage of maximum, minimum, average value.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree

 

THREE-AXIS ULTRASONIC ANEMOMETER FOR WIND SPEED & DIRECTION MEASUREMENT DELTA OHM HD2003 HD2003.1

• Determination of the anemometric quantities represented in diverse measurement units:
• wind speed and direction,
• U-V-W Cartesian components of speed,
• sound speed,
• sonic temperature
• 5 analogue voltage or current outputs, with different measuring ranges.
• RS232 and Multidrop RS485 Serial Communication interfaces.

 

NET RADIOMETER FOR ULTRAVIOLET TO INFRARED SOLAR RADIATION MEASUREMENT DELTA OHM LP NET07

• LP NET 07 measures the net radiation across a surface, from near ultraviolet to
• far infrared.
• The Net radiation is defined as the difference between the radiation that reaches the upper surface and the irradiation on the lower surface of the net radiometer.
• The surface of the upper receiver measures the direct solar radiation plus the diffuse one and the radiation at longer wavelengths emitted from the sky (clouds), while the lower receiving area measures the solar radiation reflected from the ground (albedo) and the radiation length wavelengths emitted from the earth.
• The instrument is designed and constructed to be used outdoors in any weather
• conditions.

 

DISSOLVED OXIGEN TESTER WITH THERMOMETER AND DATALOGGING DELTA OHM HD2109.1 HD2109.2

• Oxygen meter-Thermometer measures dissolved oxygen, saturation index and temperature.
• Datalogger which stores the maximum, minimum, average value and can store up to 18,000 samples.
• RS232 C/ USB output for data transfer in real time to a PC or printer.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree.