Thermo Hygrometer Delta Ohm HD2101.1 HD2101.2

Code: Delta Ohm HD2101.1 HD2101.2


 

Datasheet PDF, 0.24 Mb
   

Description

Thermo hygrometer, instrument measuring range for temperature -200°C +650°C with probe TP47...

humidity 0.0...100.0%RH

Storage of maximum, minimum, average value

RS232 C output for data transfer in real time to a PC or printer

Functions: REL, HOLD and auto power off which can be disabled

IP 67 protection degree

 

Complete with carrying case, instruction manual, 4 batteries, software DeltaLog 9. The combined humidity and temperature probes complete with SICRAM module HP... series have to be ordered separately. TP47...series temperature probes can be connected.

 

More products SENSECA

MINI-DATALOGGER FOR TEMPERATURE AND RELATIVE HUMIDITY DELTA OHM HD206 HD226 HD207 HD227

• TEMPERATURE and RELATIVE HUMIDITY mini data logger with/no display
• Selectable storage interval 1-5-10-15-30 sec/min, 1 hour.
• Storage of 120,000 reading per channel,
• 8mm 3 ½ digit LCD display.
• IP54 protection degree.

 

HVACR DATALOGGER FOR AIR SPEED, FLOW, PRESSURE, TEMPERATURE DELTA OHM DO2003

• HVACR Datalogger to measure: air speed and flow rate with the hot wire probes, vane probes, Pitot tube probes,
• Pt100 temperature probes for immersion, pointed and for surface,
• combined temperature/relative humidity probes.
• Pressure up to 2000 mbar and barometric pressure.
• Max-Min-Med, Rel measurements.
• Storage up to 12,000 readings.
• Serial output RS232C


RADIOMETRIC PROBE FOR OUTDOOR MEASURING OF SOLAR IRRADIANCE DELTA OHM LP UVA02

• Radiometric probe for outdoor use for measuring IRRADIANCE in the range UVA (315...400nm).
• mV per mW/cm2 output.
• Complete with Calibration Report.
• On request 5 or 10m cables with connectors

 

LUXMETER RADIOMETER MEASURING ILLUMINANCE, PAR, IRRADIANCE DELTA OHM HD2302.0 HD2302.0VP474

• Device for measuring illuminance, luminance, PAR, irradiance
• Storage of maximum, minimum, average value.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree

 

LABORATORY BENCHTOP CONDUCTIVITY-METER-THERMOMETER WITH LIQUID RESISTIVITY, DISSOLVED SOLIDS TDS DELTA OHM HD2206.2

• Bench-top conductivity meter-Thermometer with back-lighted display,
• with inputs for measurements of conductivity, liquid resistivity, total dissolved solids (TDS) and the salinity by conductivity and temperature
• combined probes with 2 or 4 electrodes with direct input or with SICRAM module.
• Datalogger of conductivity or resistivity or TDS and temperature.
• RS232 C or USB 2.0 serial output for data download to a PC or printer from memory or in real time.
• Input for Pt100 or Pt1000 temperature probes provided with SICRAM module.

 

CENTESIMAL THERMOMETER DELTA OHM HD2107.1 HD2107.2 HD2127.1 HD2127.2

• Centesimal thermometer in the range +/-199.99°C, decimal outside this range
• one input for Pt100 probes with SICRAM module measuring range -200°C +650°C
• Storage of maximum, minimum, average value
• RS232 C output for data transfer in real time to a PC or printer
• Functions: REL, HOLD and auto power

 

SILICON PHOTODIODE PYRANOMETER WITH GLOBAL SOLAR RADIATION MEASUREMENT FOR PHOTOVOLTAIC PANELS DELTA OHM LP SILICON-PYRA04

• LP Silicon-PYRA 04. pyranometer
• measures the global solar radiation (W/m2) by using a silicon photodiode (400nm-1100nm).
• special geometry and the diffuser allow to have a pyranometer field of view of 180 degrees according to cosine law.
• The pyranometer is suitable for the measurement of natural sunlight.

 

PLUVIOMETER RAIN GAUGE FOR ATMOSFERIC PRECIPITATION DELTA OHM HD2013

• Rain gauge with tipping bucket,
• area 400cm2,
• for temperature range +4°C... +60°C.
• Standard resolution 0.2.
• On request at the time of placing the order resolution 0.1 or 0.5mm.
• Output contact normally closed.

 

SOUND LEVEL CALIBRATOR WITH AUDIO SIGNAL GENERATOR FOR ACOUSTIC CALIBRATIONS CLASS I/II DELTA OHM HD9101 HD9102

• generator noise level 9101/HD HD 9102
• portable, battery-powered sound source,
• suitable for calibration of sound level meters (portable and laboratory) and acoustic measuring stations
• possible to calibrate directly microphones 1 / 2 "of mechanical dimensions conform to the requirements of IEC 61094-1
• the frequency of the sound signal at 1000Hz can perform calibration of sound level meters with any frequency weighting
• sound pressure level generated is independent of atmospheric pressure
• Ease of use allows the use even by unskilled personnel.

 

HANDHELD DIGITAL THERMOCOUPLE THERMOMETER K, J, T, R, N, S, B, E DELTA OHM HD2108.1 HD2108.2 HD2128.1 HD2128.2

• Thermocouple thermometer with one input and logger 32.000 samples
• For K, J, T, R, N, S, B, E type probes with miniature connector
• Storage of maximum, minimum, average value,
• USB/RS232 C connection to download loggerdata to PC.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree