Handheld Digital Thermocouple Thermometer K J T E Delta Ohm HD2328.0

Code: Delta Ohm HD2328.0


 

Datasheet PDF, 0.2 Mb
 

Description

Thermocouple thermometer for probes type K, J, T, E. Two inputs for miniature thermocouple connectors. Storage of maximum, minimum, average value. Functions: REL, HOLD and auto power off which can be disabled, IP 67 protection degree. Complete with carrying case, instruction manual, 3 batteries, the probes have to be ordered separately. All the thermocouples type K available in this price-list at page 108 can be connected.

 

More products SENSECA

INDOOR QUALITY ANALYSIS IAQ MONITORING DATALOGGER CO CO2 DELTA OHM HD37AB1347

• Datalogger for indoor air quality analysis (IAQ)
• measures: airspeed, temperature, relative humidity, atmospheric pressure, CO2 (Carbon Dioxide) and CO (Carbon Monoxide)
• Memory capacity of 67,600 records for each of the two inputs.
• Logging interval from 15 seconds to 1 hour.

 

PH AND MV-METER SIMULATOR CALIBRATING KIT DELTA OHM HD9609

• pH/mV simulator kit composed of instrument HD9609,
• adapter cables CP 9509/T,
• CP9509/BNC and
• carrying case.

 

DISSOLVED OXIGEN TESTER WITH THERMOMETER AND DATALOGGING DELTA OHM HD2109.1 HD2109.2

• Oxygen meter-Thermometer measures dissolved oxygen, saturation index and temperature.
• Datalogger which stores the maximum, minimum, average value and can store up to 18,000 samples.
• RS232 C/ USB output for data transfer in real time to a PC or printer.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree.

 

FIRST CLASS PYRHELIOMETER FOR DIRECT SOLAR IRRADIANCE MEASUREMENT DELTA OHM LP PIRHE16

• The pyrheliometer LP PYRHE 16 First Class Pyrheliometer according to ISO 9060 classification
• is an instrument for direct measurement of solar irradiance (Watt/m2).
• The receiving surface must be positioned (via a solar tracker or else) perpendicularly to sun’s rays.
• By using suitable diaphragms only the direct light reaches the surface of the sensor.
• According to WMO (Seventh Edition 2008) and ISO 9069 regulations, the pyrheliometer has a field of view of 5°.

 

SOUND LEVEL CALIBRATOR WITH AUDIO SIGNAL GENERATOR FOR ACOUSTIC CALIBRATIONS CLASS I/II DELTA OHM HD9101 HD9102

• generator noise level 9101/HD HD 9102
• portable, battery-powered sound source,
• suitable for calibration of sound level meters (portable and laboratory) and acoustic measuring stations
• possible to calibrate directly microphones 1 / 2 "of mechanical dimensions conform to the requirements of IEC 61094-1
• the frequency of the sound signal at 1000Hz can perform calibration of sound level meters with any frequency weighting
• sound pressure level generated is independent of atmospheric pressure
• Ease of use allows the use even by unskilled personnel.

 

RADIOMETRIC PROBE FOR OUTDOOR MEASURING OF SOLAR IRRADIANCE DELTA OHM LP UVA02

• Radiometric probe for outdoor use for measuring IRRADIANCE in the range UVA (315...400nm).
• mV per mW/cm2 output.
• Complete with Calibration Report.
• On request 5 or 10m cables with connectors

 

RAIN DETECTOR AND ATHMOSPHERICAL PRECIPITATION DELTA OHM HD2013.2

• rain detector based on the capacity principle
• The instrument is equipped with three different outputs: a "Rain ON/OFF" output
• detects whether it is raining/ snowing (ON) or not (OFF), also used to control a relay coil or similar devices
• can be used either as a separate device, or connected to a data logger system

 

PORTABLE PHOTO-RADIOMETER DATALOGGER TO MEASURE NON-COHERENT OPTICAL RADIATION ACC.EUROPEAN DIRECTIVE 2006/25/EC DELTA OHM HD2402

• portable photo-radiometer data logger for the measurement of noncoherent optical radiation
• in accordance with European Directive 2006/25/EC and the Legislative Decree No 81, April 9, 2008.
• Photometric sensor for measuring the illuminance (lux meter) in the spectralrange 380÷780 nm.
• Radiometric sensor for the UV band (220÷400 nm) with spectral weighing factor S(?).
• Radiometric sensor for UVA band (315÷400 nm).
• Radiometric sensor for the band 400÷700 nm (blue) with spectral weighing factor B (?).
• Radiometric sensor for the IR band (700÷1300 nm) with spectral weighing factor R(?).
• Thermopile sensor for the measurement of irradiance in the infrared spectral range 400÷2800 nm.

 

MONO-AXIAL ACCELEROMETER AND TRIAXIAL ACCELEROMETER ICP MECHANICAL VIBRATIONS DELTA OHM

• HD356A02: tri-axial accelerometer for the measurement of vibrations transmitted to the handarm system
• HD356B21: miniature tri-axial accelerometer for the measurement of vibrations transmitted to the hand-arm system
• HD356B41: tri-axial accelerometer inserted in a rubber pad for the measurement of the vibrations trasnmitted to the whole body
• HD356A22: tri-axial accelerometer for general application
• HD352C34: mono-axial accelerometer for general application
• HD356B20: miniature tri-axial accelerometer for the measurement of vibrations transmitted to the hand-arm system at high shock level

 

MULTIPARAMETRIC PH-METER-CONDUCTIVIMETER-THERMOMETER DELTA OHM HD2156.1 HD2156.2

• pHmeter-Conductivity-Thermometer measures pH, mV, conductivity, liquid resistivity, total dissolved solids, salinity and temperature.
• Datalogger, stores the maximum, minimum, average value and can store up to 20,000 sets of three measurements.
• USB output for data transfer in real time to a PC or printer.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree.