Datalooger with Microclimate analysis WBGT PMV PPD Delta Ohm HD32.3 HD32.3A

Code: Delta Ohm HD32.3 HD32.3A


 

Datasheet PDF, 0.65 Mb
 

Description

• Analysis of hot environments using WBGT index (Wet Bulb Glob Temperature:
wet bulb temperature and Globe thermometer) in presence or absence of solar radiation.
• Analysis of the moderate warm environments using PMV index (Predicted Mean Vote) and PPD index (Predicted Percentage of Dissatisfied).
Reference Rules:
ISO 7243: Hot environments. Estimation of the heat stress on working man, based on WBGT index (wet bulb globe Thermometer).
ISO 8996: Ergonomics of the thermal environment. Determination of metabolic rate.
ISO 7726: Ergonomics of the thermal environment - Instruments for measuring physical quantities.
ISO 7730: Moderate thermal environments. Determination of PMV and PPD index and specification of the condition for thermal comfort.
The instrument is provided with three inputs for probes with SICRAM module:
the SICRAM module interface between the instrument and sensor connected and communicate the sensor parameters and calibration data to the instrument.
All SICRAM probes can be plugged into any of the inputs: they are automatically recognized upon turning on the instrument.
The main features of the instrument are:
• Logging: data acquisition and logging In the integral instrument memory. Storage capacity: 64 different logging sections, sample interval, user selectable.
• Start and stop can be set automatically with the auto-start function,
• Selectable measurement unit of the temperature: °C, °F, °K.
• Date and time of the instrument.
• The display of maximum, minimum, medium statistic parameters and their deletion.
• The transfer speed of data via RS232 serial port.

Standard kit consists of four AA 1.5 V batteries, instruction manual, software Deltalog 10 for WBGT, PMV and PPD index analysis. The probes and cables have to be ordered separately. The probes necessary for WBGT measurement are the following: · Dry bulb temperature probes TP3207.2. · Globe temperature probe TP3276.2. - Natural ventilation wet bulb temperature probe HP3201.2. The probes necessary for PMV and PPD measurement are the following: · Relative humidity and temperature combined probe HP3217.2. · Omnidirectional hotwire probe AP3203.2. · Globe temperature probe TP3276.2.

 

More products SENSECA

LABORATORY TESTER FOR ELECTROCHEMICAL PARAMETERS: PH, CONDUCTIVITY, DISSOLVED OXYGEN, TEMPERATURE, CONCENTRATION, SOLIDS, SALINITY DELTA OHM HD22569.2

• bench top instrument for electrochemical measures: pH, conductivity, dissolved oxygen, and temperature.
• It is are fitted with a large backlighted LCD display.
• pH, mV, redox potential (ORP) with pH, redox electrodes or electrodes with separate reference;
• conductivity, resistivity in liquids,
• total dissolved solids (TDS) and salinity with combined 4-ring and 2-ring conductivity/
• temperature probes with direct input or SICRAM module;
• concentration of dissolved oxygen in liquids (in mg/l) and saturation index (in %),

 

HVACR DATALOGGER FOR AIR SPEED, FLOW, PRESSURE, TEMPERATURE DELTA OHM DO2003

• HVACR Datalogger to measure: air speed and flow rate with the hot wire probes, vane probes, Pitot tube probes,
• Pt100 temperature probes for immersion, pointed and for surface,
• combined temperature/relative humidity probes.
• Pressure up to 2000 mbar and barometric pressure.
• Max-Min-Med, Rel measurements.
• Storage up to 12,000 readings.
• Serial output RS232C


RADIOMETRIC PROBE FOR OUTDOOR MEASURING OF SOLAR IRRADIANCE DELTA OHM LP UVA02

• Radiometric probe for outdoor use for measuring IRRADIANCE in the range UVA (315...400nm).
• mV per mW/cm2 output.
• Complete with Calibration Report.
• On request 5 or 10m cables with connectors

 

METEO PIRGEOMETER FOR INFRARED RADIATION MEASUREMENT DELTA OHM LP PIRG01

• The pyrgeometer LP PIRG 01 is used to measure the far infrared radiation (FIR).
• Its use is mainly in the meteorological field.
• Measures are referred to radiations with wavelength greater than 4.5 µm .
• The far infrared radiation derives from the measure of the thermopile output signal and from the knowledge of the instrument temperature. The temperature measure is performed by a 10kO NTC which is inside the body of the pyrgeometer.
• The pyrgeometer can be used also for the study of energy balance

 

DUAL INPUT THERMOMETER DELTA OHM HD2178.1 HD2178.2

• Thermometer with two inputs, the first for Pt100 probes equipped with SICRAM module, the second input for thermocouple type K, J, T, E, N
• large display
• Storage of maximum, minimum, average value
• RS232 C output for data transfer in real time to a PC or printer
• Functions: REL, HOLD and auto power off which can be disabled
• IP 67 protection degree

 

PH AND MV-METER SIMULATOR CALIBRATING KIT DELTA OHM HD9609

• pH/mV simulator kit composed of instrument HD9609,
• adapter cables CP 9509/T,
• CP9509/BNC and
• carrying case.

 

PLUVIOMETER RAIN GAUGE FOR ATMOSFERIC PRECIPITATION DELTA OHM HD2013

• Rain gauge with tipping bucket,
• area 400cm2,
• for temperature range +4°C... +60°C.
• Standard resolution 0.2.
• On request at the time of placing the order resolution 0.1 or 0.5mm.
• Output contact normally closed.

 

LUXMETER RADIOMETER MEASURING ILLUMINANCE, PAR, IRRADIANCE DELTA OHM HD2302.0 HD2302.0VP474

• Device for measuring illuminance, luminance, PAR, irradiance
• Storage of maximum, minimum, average value.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree

 

CLASS I AUDIO ANALYZER WITH DATALOGGER, THIRD OCTAVE SPECTRUM ANALYSIS, STATISTICS DELTA OHM HD2110L

• precision integrating portable sound level meter
• data logging function
• performing both spectrum and statistical analysis
• high-performance analysis of acoustic phenomena
• Class 1 sound level meter according to IEC 61672-1, 2002 , IEC 60651 and IEC 60804
• Class 1 octave and third octave filters according to IEC 61260
• Real-time octave and third octave band spectrum analysis from 16 Hz to 20 kHz
• Narrow-band spectral analysis (FFT) with variable resolution from 1.5Hz to 100Hz and capture of the Leq profile at intervals of 1/32s

 

LUXMETER PHOTO- RADIOMETER MEASURING SOLAR ILLUMINANCE, PAR, IRRADIANCE DELTA OHM HD2102.1 HD2102.2

• Device for measuring illuminance, luminance, PAR, irradiance.
• Storage of maximum, minimum, average value and the integral Q(t),
• RS232 C output for data transfer in real time to a PC or printer.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree