Code: Delta Ohm HD32.3 HD32.3A
Description
• Analysis of hot environments using WBGT index (Wet Bulb Glob Temperature:
wet bulb temperature and Globe thermometer) in presence or absence of solar radiation.
• Analysis of the moderate warm environments using PMV index (Predicted Mean Vote) and PPD index (Predicted Percentage of Dissatisfied).
Reference Rules:
ISO 7243: Hot environments. Estimation of the heat stress on working man, based on WBGT index (wet bulb globe Thermometer).
ISO 8996: Ergonomics of the thermal environment. Determination of metabolic rate.
ISO 7726: Ergonomics of the thermal environment - Instruments for measuring physical quantities.
ISO 7730: Moderate thermal environments. Determination of PMV and PPD index and specification of the condition for thermal comfort.
The instrument is provided with three inputs for probes with SICRAM module:
the SICRAM module interface between the instrument and sensor connected and communicate the sensor parameters and calibration data to the instrument.
All SICRAM probes can be plugged into any of the inputs: they are automatically recognized upon turning on the instrument.
The main features of the instrument are:
• Logging: data acquisition and logging In the integral instrument memory. Storage capacity: 64 different logging sections, sample interval, user selectable.
• Start and stop can be set automatically with the auto-start function,
• Selectable measurement unit of the temperature: °C, °F, °K.
• Date and time of the instrument.
• The display of maximum, minimum, medium statistic parameters and their deletion.
• The transfer speed of data via RS232 serial port.
Standard kit consists of four AA 1.5 V batteries, instruction manual, software Deltalog 10 for WBGT, PMV and PPD index analysis. The probes and cables have to be ordered separately. The probes necessary for WBGT measurement are the following: · Dry bulb temperature probes TP3207.2. · Globe temperature probe TP3276.2. - Natural ventilation wet bulb temperature probe HP3201.2. The probes necessary for PMV and PPD measurement are the following: · Relative humidity and temperature combined probe HP3217.2. · Omnidirectional hotwire probe AP3203.2. · Globe temperature probe TP3276.2.
More products SENSECA
|
CONDUCTIVIMETER-THERMOMETER FOR CONDUCTIVITY, LIQUID RESISTIVITY, DISSOLVED SOLIDS, SALINITY, TEMPERATURE DELTA OHM HD2306.0
• Conductivity-Thermometer measures conductivity, liquid resistivity, total dissolved solids, salinity and temperature. |
|
AIR QUALITY ANALYSIS MONITORING DATALOGGER CO CO2 DELTA OHM HD37AB17D HD37B17D
• data loggers able to measure and memorize simultaneously the following parameters: |
|
TWO-AXIS ULTRASONIC ANEMOMETER FOR WINDSPEED & WINDDIRECTION MEASUREMENT DELTA OHM HD52.3
• 2 axes ultrasonic Anemometers series HD 52.3D |
|
ALBEDOMETER PYRANOMETER FOR GLOBAL INCIDENT SOLAR RADIATION DELTA OHM LPPYRA05
• Albedometer First and Second Class pyranometers according to ISO 9060. |
|
MICRO MANOMETER-THERMOMETER DELTA OHM HD2114P HD2134P
• Micromanometer-Thermometer for air speed and flow rate measurement by means of Pitot tubes |
|
PORTABLE LABORATORY TURBIDITY-METER FOR LPROCESS IQUIDS, DRINKING WATER, WASTE WATER DELTA OHM HD25.2
• Portable and bench turbidity meter equipped with 3 photodetectors and two light sources |
|
LABORATORY BENCH PHMETER-THERMOMETER WITH PH, MV, REDOX POTENTIAL DELTA OHM HD2205.2
• Bench-top pHmeter-Thermometer with back-lighted display, |
|
ANEMOMETER-THERMOMETER AIR SPEED MEASUREMENT DELTA OHM HD2303.0
• Anemometer-Thermometer for air speed measurement which use hot-wire or vane probes, for temperature Pt100 sensor with SICRAM module. |
|
CLASS I AUDIO ANALYZER WITH DATALOGGER, THIRD OCTAVE SPECTRUM ANALYSIS, STATISTICS DELTA OHM HD2110L
• precision integrating portable sound level meter |
|
PORTABLE PHOTO-RADIOMETER DATALOGGER TO MEASURE NON-COHERENT OPTICAL RADIATION ACC.EUROPEAN DIRECTIVE 2006/25/EC DELTA OHM HD2402
• portable photo-radiometer data logger for the measurement of noncoherent optical radiation |