Datalooger with Microclimate analysis WBGT PMV PPD Delta Ohm HD32.3 HD32.3A

Code: Delta Ohm HD32.3 HD32.3A


 

Datasheet PDF, 0.65 Mb
 

Description

• Analysis of hot environments using WBGT index (Wet Bulb Glob Temperature:
wet bulb temperature and Globe thermometer) in presence or absence of solar radiation.
• Analysis of the moderate warm environments using PMV index (Predicted Mean Vote) and PPD index (Predicted Percentage of Dissatisfied).
Reference Rules:
ISO 7243: Hot environments. Estimation of the heat stress on working man, based on WBGT index (wet bulb globe Thermometer).
ISO 8996: Ergonomics of the thermal environment. Determination of metabolic rate.
ISO 7726: Ergonomics of the thermal environment - Instruments for measuring physical quantities.
ISO 7730: Moderate thermal environments. Determination of PMV and PPD index and specification of the condition for thermal comfort.
The instrument is provided with three inputs for probes with SICRAM module:
the SICRAM module interface between the instrument and sensor connected and communicate the sensor parameters and calibration data to the instrument.
All SICRAM probes can be plugged into any of the inputs: they are automatically recognized upon turning on the instrument.
The main features of the instrument are:
• Logging: data acquisition and logging In the integral instrument memory. Storage capacity: 64 different logging sections, sample interval, user selectable.
• Start and stop can be set automatically with the auto-start function,
• Selectable measurement unit of the temperature: °C, °F, °K.
• Date and time of the instrument.
• The display of maximum, minimum, medium statistic parameters and their deletion.
• The transfer speed of data via RS232 serial port.

Standard kit consists of four AA 1.5 V batteries, instruction manual, software Deltalog 10 for WBGT, PMV and PPD index analysis. The probes and cables have to be ordered separately. The probes necessary for WBGT measurement are the following: · Dry bulb temperature probes TP3207.2. · Globe temperature probe TP3276.2. - Natural ventilation wet bulb temperature probe HP3201.2. The probes necessary for PMV and PPD measurement are the following: · Relative humidity and temperature combined probe HP3217.2. · Omnidirectional hotwire probe AP3203.2. · Globe temperature probe TP3276.2.

 

More products SENSECA

INDOOR QUALITY ANALYSIS IAQ MONITORING DATALOGGER CO CO2 DELTA OHM HD37AB1347

• Datalogger for indoor air quality analysis (IAQ)
• measures: airspeed, temperature, relative humidity, atmospheric pressure, CO2 (Carbon Dioxide) and CO (Carbon Monoxide)
• Memory capacity of 67,600 records for each of the two inputs.
• Logging interval from 15 seconds to 1 hour.

 

HANDHELD DIGITAL THERMOCOUPLE THERMOMETER K J T E DELTA OHM HD2328.0

• Thermocouple thermometer for probes type K, J, T, E
• Two inputs for miniature thermocouple connectors
• Storage of maximum, minimum, average valu
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree

 

LUXMETER RADIOMETER MEASURING ILLUMINANCE, PAR, IRRADIANCE DELTA OHM HD2302.0 HD2302.0VP474

• Device for measuring illuminance, luminance, PAR, irradiance
• Storage of maximum, minimum, average value.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree

 

PHOTOMETRIC PROBE FOR OUTDOOR MEASURING OF SOLAR ILLUMINANCE DELTA OHM LP PHOT02

• Outdoor photometric probe for measuring ILLUMINANCE (0...150 Klux),
• CIE photopic filter,
• diffuser for cosine correction.
• mVdc output for klux.
• Complete with Calibration Report.
• On request 5 or 10m cables with connectors.

 

MANOMETERS-THERMOMETERS DELTA OHM HD2114 HD2134 HD2164

• portable instruments with a large LCD display
• They measure absolute, relative and differential pressure, as well as temperature
• Max, Min and Avg function calculates the maximum, minimum or average values
• relative measurement REL, the HOLD function, and the automatic turning off
• store up to 36,000 samples
• standard RS232C serial port and USB 2.0

 

RADIOMETRIC PROBE FOR OUTDOOR MEASURING OF SOLAR IRRADIANCE DELTA OHM LP UVA02

• Radiometric probe for outdoor use for measuring IRRADIANCE in the range UVA (315...400nm).
• mV per mW/cm2 output.
• Complete with Calibration Report.
• On request 5 or 10m cables with connectors

 

DATALOOGER WITH MICROCLIMATE ANALYSIS WBGT DELTA OHM HD32.2 HD32.2A

• analysis of WBGT index (Wet Bulb Glob Temperature: wet bulb temperature and globe thermometer temperature) in presence or in absence of solar radiation
• Logging
• data transfer speed via the RS232 serial port
• The measurement unit of the temperature: °C, °F, °K
• Date and time of the instrument
• display of maximum, minimum, medium statistic parameters and their deletion

 

SECONDARY CLSSS PYRANOMETER ACCORDING TO WMO STANDARD ISO9060 DELTA OHM LP PYRA08

• Second class pyranometer according to ISO 9060,
• fast response sensor complete with calibration report,
• possibility to replace the exhausted silica-gel.
• Different configurations available.
• Male M12 connector.
• On request cables with M12 female connector: CPM12AA, length 2, 5, 10m.

 

SECONDARY CLASS PYRANOMETER FOR DIRECT SOLAR IRRADIANCE ON FLAT SURFACE AND GLOBAL RADIATION DELTA OHM LP PYRA10

• measures the irradiance on a flat surface (Watt/m2)
• pyranometer classified as Secondary in accordance with ISO 9060
• according to the publication "Guide to Meteorological Instruments and Methods of Observation", fifth edition (1983) of WMO
• LP PYRA 10 PASSIVE *
• LP PYRA 10 AC ACTIVE with CURRENT 4..20 mA output
• LP PYRA 10 AV ACTIVE with VOLTAGE 0..1 V, 0..5 V, 0..10 V output

 

INTEGRATING SOUND LEVEL METER CLASS I / CLASS II WITH DATALOGGING, SPECTRAL ANALYSIS & STATISTICS DELTA OHM HD2010UC/A

• portable integrating class 1 sound level meter, with data logging function, suitable for performing statistical and spectral analyses
• possibility of adjusting the instrument and adding options at any time
• user can upgrade the firmware directly by means of the Noise Studio programme supplied with the instrument
• Class 1 or 2 sound level meter according to IEC 61672-1 IEC 60651 and IEC 60804
• Class 1 octave and third octave filters according to IEC 61260
• Assessment of the environmental noise level,
• Noise monitoring and optional capture and analysis of sound events,
• Octave and optional third octave band spectrum analysis from 25 Hz to 12.5 kHz,