Handheld Digital Thermometer Pt100 Sensor -200°C +650°C Delta Ohm HD2307.0

Code: Delta Ohm HD2307.0


 

Datasheet PDF, 0.18 Mb

Description

Thermometer, Pt100 sensor with one input for probes equipped with SICRAM module, measuring range -200°C +650°C. Storage of maximum, minimum, average value. Functions: REL, HOLD and auto-power-off which can be disabled, IP 67 protection degree. Complete with carrying case, instruction manual, 3 batteries, the probes have to be ordered separately. TP47...series probes are suitable.

 

More products SENSECA

PORTABLE CLASS I INTEGRATING SOUND LEVEL METER WITH SPECTRUM ANALYSIS ANS STATISTICS DELTA OHM HD2010

• precision integrating portable sound level meter
• data logging functions
• performing both spectrum and statistical analysis
• maximum flexibility and simplicity
• firmware can be directly updated by the user by means of the Noise Studio program supplied with the instrument
• Class 1 sound level meter according to IEC 61672-1, 2002
• Class 1 octave and third octave filters according to IEC 61260
• Microphone complying with IEC 61094-4
• Noise monitoring and optional capture and analysis of sound events
• Octave and optional third octave band spectrum analysis from 16 Hz to 20 kHz

 

NET RADIOMETER WITH 4-COMPONENTS FOR SOLAR RADIATION MEASUREMENTS DELTA OHM LP NET14

• LP NET 14 is a 4-component net-radiometer for the measurement of the net radiation between 0.3µm and 45 µm.
• consists of two pyranometers: one for the measurement of the global radiation Esw? and the other one for the measurement of the reflected solar radiation Esw?
• pair of pyrgeometers: one for the measurement of the infrared radiation emitted by the sky EFIR? and the other one for the infrared emitted by the ground surface EFIR?
• equipped with a temperature sensor (NTC).

 

LABORATORY TESTER FOR ELECTROCHEMICAL PARAMETERS: PH, CONDUCTIVITY, DISSOLVED OXYGEN, TEMPERATURE, CONCENTRATION, SOLIDS, SALINITY DELTA OHM HD22569.2

• bench top instrument for electrochemical measures: pH, conductivity, dissolved oxygen, and temperature.
• It is are fitted with a large backlighted LCD display.
• pH, mV, redox potential (ORP) with pH, redox electrodes or electrodes with separate reference;
• conductivity, resistivity in liquids,
• total dissolved solids (TDS) and salinity with combined 4-ring and 2-ring conductivity/
• temperature probes with direct input or SICRAM module;
• concentration of dissolved oxygen in liquids (in mg/l) and saturation index (in %),

 

CLASS I AUDIO ANALYZER WITH DATALOGGER, THIRD OCTAVE SPECTRUM ANALYSIS, STATISTICS DELTA OHM HD2110L

• precision integrating portable sound level meter
• data logging function
• performing both spectrum and statistical analysis
• high-performance analysis of acoustic phenomena
• Class 1 sound level meter according to IEC 61672-1, 2002 , IEC 60651 and IEC 60804
• Class 1 octave and third octave filters according to IEC 61260
• Real-time octave and third octave band spectrum analysis from 16 Hz to 20 kHz
• Narrow-band spectral analysis (FFT) with variable resolution from 1.5Hz to 100Hz and capture of the Leq profile at intervals of 1/32s

 

METEO PIRGEOMETER FOR INFRARED RADIATION MEASUREMENT DELTA OHM LP PIRG01

• The pyrgeometer LP PIRG 01 is used to measure the far infrared radiation (FIR).
• Its use is mainly in the meteorological field.
• Measures are referred to radiations with wavelength greater than 4.5 µm .
• The far infrared radiation derives from the measure of the thermopile output signal and from the knowledge of the instrument temperature. The temperature measure is performed by a 10kO NTC which is inside the body of the pyrgeometer.
• The pyrgeometer can be used also for the study of energy balance

 

HANDHELD DIGITAL THERMOMETER PT100 SENSOR -200°C +650°C DELTA OHM HD2307.0

• Thermometer, Pt100 sensor with one input for probes equipped with SICRAM module,
• measuring range -200°C +650°C
• Storage of maximum, minimum, average value
• Functions: REL, HOLD and auto-power-off which can be disabled
• IP 67 protection degree

 

3-CHANNEL MULTIFUNCTION AIR PARAMETERS MONITORING DATALOGGER DELTA OHM DO9847

• Multifunctional handheld board instrument and datalogger
• RH, temperature, pressure, airspeed, light, voltage, current
• 128x64 pixel (56x38 mm) graphic display and three independent inputs
• Functions: watch, hold, max., min., average, record, immediate or deferred start record logging, difference between the two inputs, relative measures
• Storage capacity: 32.000 readings per input.
• RS232C serial output: from 300 up to 115.200 baud rate.

 

THERMO HYGROMETER DELTA OHM HD2101.1 HD2101.2

• Thermo hygrometer, instrument measuring range for temperature -200°C +650°C with probe TP47...
• humidity 0.0...100.0%RH
• Storage of maximum, minimum, average value
• RS232 C output for data transfer in real time to a PC or printer
• Functions: REL, HOLD and auto power off which can be disabled
• IP 67 protection degree

 

PORTABLE PHOTO-RADIOMETER DATALOGGER TO MEASURE NON-COHERENT OPTICAL RADIATION ACC.EUROPEAN DIRECTIVE 2006/25/EC DELTA OHM HD2402

• portable photo-radiometer data logger for the measurement of noncoherent optical radiation
• in accordance with European Directive 2006/25/EC and the Legislative Decree No 81, April 9, 2008.
• Photometric sensor for measuring the illuminance (lux meter) in the spectralrange 380÷780 nm.
• Radiometric sensor for the UV band (220÷400 nm) with spectral weighing factor S(?).
• Radiometric sensor for UVA band (315÷400 nm).
• Radiometric sensor for the band 400÷700 nm (blue) with spectral weighing factor B (?).
• Radiometric sensor for the IR band (700÷1300 nm) with spectral weighing factor R(?).
• Thermopile sensor for the measurement of irradiance in the infrared spectral range 400÷2800 nm.

 

NET RADIOMETER FOR ULTRAVIOLET TO INFRARED SOLAR RADIATION MEASUREMENT DELTA OHM LP NET07

• LP NET 07 measures the net radiation across a surface, from near ultraviolet to
• far infrared.
• The Net radiation is defined as the difference between the radiation that reaches the upper surface and the irradiation on the lower surface of the net radiometer.
• The surface of the upper receiver measures the direct solar radiation plus the diffuse one and the radiation at longer wavelengths emitted from the sky (clouds), while the lower receiving area measures the solar radiation reflected from the ground (albedo) and the radiation length wavelengths emitted from the earth.
• The instrument is designed and constructed to be used outdoors in any weather
• conditions.