HVACR Datalogger for Air speed, flow, Pressure, Temperature Delta Ohm DO2003

Code: Delta Ohm DO2003


 

Description

HVACR Datalogger to measure: air speed and flow rate with the hot wire probes, vane probes, Pitot tube probes, Pt100 temperature probes for immersion, pointed and for surface, combined temperature/relative humidity probes. Pressure up to 2000 mbar and barometric pressure. Max-Min-Med, Rel measurements. Storage up to 12,000 readings. Serial output RS232C. Configurable storing and printing interval. The kit is provided with the instrument DO2003, carrying case, instruction manual, 4 batteries, Software DeltaLog 3. The air speed probes, Pitot tubes, temperature probes, temperature and humidity probes, pressure probes and cables for data download (9CPRS232) have to be ordered separately.

 

More products SENSECA

PORTABLE LABORATORY TURBIDITY-METER FOR LPROCESS IQUIDS, DRINKING WATER, WASTE WATER DELTA OHM HD25.2

• Portable and bench turbidity meter equipped with 3 photodetectors and two light sources
• it measures according to the standard EPA 180.1, ISO-NEPH (ISO 7027), EBC and ASBC.
• Automatic calibration,
• datalogger,
• data downloading to PC by RS232C or USB 2.0 through the software DeltaLog11

 

NET RADIOMETER FOR ULTRAVIOLET TO INFRARED SOLAR RADIATION MEASUREMENT DELTA OHM LP NET07

• LP NET 07 measures the net radiation across a surface, from near ultraviolet to
• far infrared.
• The Net radiation is defined as the difference between the radiation that reaches the upper surface and the irradiation on the lower surface of the net radiometer.
• The surface of the upper receiver measures the direct solar radiation plus the diffuse one and the radiation at longer wavelengths emitted from the sky (clouds), while the lower receiving area measures the solar radiation reflected from the ground (albedo) and the radiation length wavelengths emitted from the earth.
• The instrument is designed and constructed to be used outdoors in any weather
• conditions.

 

FIRST CLASS PYRHELIOMETER FOR DIRECT SOLAR IRRADIANCE MEASUREMENT DELTA OHM LP PIRHE16

• The pyrheliometer LP PYRHE 16 First Class Pyrheliometer according to ISO 9060 classification
• is an instrument for direct measurement of solar irradiance (Watt/m2).
• The receiving surface must be positioned (via a solar tracker or else) perpendicularly to sun’s rays.
• By using suitable diaphragms only the direct light reaches the surface of the sensor.
• According to WMO (Seventh Edition 2008) and ISO 9069 regulations, the pyrheliometer has a field of view of 5°.

 

HANDHELD DIGITAL THERMOCOUPLE THERMOMETER K, J, T, R, N, S, B, E DELTA OHM HD2108.1 HD2108.2 HD2128.1 HD2128.2

• Thermocouple thermometer with one input and logger 32.000 samples
• For K, J, T, R, N, S, B, E type probes with miniature connector
• Storage of maximum, minimum, average value,
• USB/RS232 C connection to download loggerdata to PC.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree

 

RAIN DETECTOR AND ATHMOSPHERICAL PRECIPITATION DELTA OHM HD2013.2

• rain detector based on the capacity principle
• The instrument is equipped with three different outputs: a "Rain ON/OFF" output
• detects whether it is raining/ snowing (ON) or not (OFF), also used to control a relay coil or similar devices
• can be used either as a separate device, or connected to a data logger system

 

MULTIFUNCTION DATALOOGER WITH MICROCLIMATE ANALYSIS DELTA OHM HD32.1

• Globe temperature
• Natural wet bulb temperature
• Ambient temperature
• Atmospheric pressure
• Relative Humidity
• Air velocity
• Air temperature at the height of the head...

 

DATALOOGER WITH MICROCLIMATE ANALYSIS WBGT DELTA OHM HD32.2 HD32.2A

• analysis of WBGT index (Wet Bulb Glob Temperature: wet bulb temperature and globe thermometer temperature) in presence or in absence of solar radiation
• Logging
• data transfer speed via the RS232 serial port
• The measurement unit of the temperature: °C, °F, °K
• Date and time of the instrument
• display of maximum, minimum, medium statistic parameters and their deletion

 

INTEGRATING SOUND LEVEL METER CLASS I OR CLASS II WITH SPECTRAL ANALYSIS & STATISTICS DELTA OHM HD2010UC

• integrating portable sound level meter performing statistical analysis
• maximum low cost and simplicity of use
• possibility of adjusting the instrument and adding options at any time
• user can upgrade the firmware directly by means of the Noise Studio programme supplied with the instrument
• Class 1 or 2 sound level meter according to IEC 61672-1 dated 2002, IEC 60651 and IEC 60804
• Assessment of the environmental noise level,
• Optional "data logging" function,
• Optional capture and analysis of sound events,
• Statistical analysis with the calculation of 3 percentile level and optional full statistical analysis

 

METEO DATALOGGER WITH DATA ACQUISITION AND RECORDING DELTA OHM HD32MT.1

• 16-channel data logger capable of capturing and logging the values measured by a series of sensors connected to its inputs
• Sensors with analog voltage output, both unipolar and bipolar
• Sensors with analog current output(0..20mA, 4..20mA)
• Temperature sensors thermocouple(typpe K, J, T, N, R, S, B, E)
• Pt100/Pt1000 and NTC temperature sensors
• Sensors with digital output TTL level pulse (ON/OFF)
• Sensors with open/close contact output(e.g. rain gauges, cup anemometers

 

METEO PIRGEOMETER FOR INFRARED RADIATION MEASUREMENT DELTA OHM LP PIRG01

• The pyrgeometer LP PIRG 01 is used to measure the far infrared radiation (FIR).
• Its use is mainly in the meteorological field.
• Measures are referred to radiations with wavelength greater than 4.5 µm .
• The far infrared radiation derives from the measure of the thermopile output signal and from the knowledge of the instrument temperature. The temperature measure is performed by a 10kO NTC which is inside the body of the pyrgeometer.
• The pyrgeometer can be used also for the study of energy balance