Laboratory Benchtop Conductivity-meter-Thermometer with liquid resistivity, dissolved solids TDS Delta Ohm HD2206.2

Code: Delta Ohm HD2206.2


 

Datasheet PDF, 0.37 Mb
 

Description

Bench-top conductivity meter-Thermometer with back-lighted display,

with inputs for measurements of conductivity, liquid resistivity, total dissolved solids (TDS) and the salinity by conductivity and temperature

combined probes with 2 or 4 electrodes with direct input or with SICRAM module.

Datalogger of conductivity or resistivity or TDS and temperature.

RS232 C or USB 2.0 serial output for data download to a PC or printer from memory or in real time.

Input for Pt100 or Pt1000 temperature probes provided with SICRAM module.

 

It is equipped with regulated power supply SWD10, instructions manual, software DELTALOG 11. Conductivity probes, buffer solutions, TP87 and TP47... series temperature probes with SICRAM module and cables for PC connection have to be ordered separately.

 

 

More products SENSECA

AIR QUALITY ANALYSIS MONITORING DATALOGGER CO CO2 DELTA OHM HD37AB17D HD37B17D

• data loggers able to measure and memorize simultaneously the following parameters:
• Relative Humidity RH
• Environment temperature T
• Carbon monoxide CO (only HD37AB17D)
• Carbon dioxide CO2
• DeltaLog13 communication software via the USB port

 

LUXMETER PHOTO- RADIOMETER MEASURING SOLAR ILLUMINANCE, PAR, IRRADIANCE DELTA OHM HD2102.1 HD2102.2

• Device for measuring illuminance, luminance, PAR, irradiance.
• Storage of maximum, minimum, average value and the integral Q(t),
• RS232 C output for data transfer in real time to a PC or printer.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree

 

DUAL INPUT THERMOMETER DELTA OHM HD2178.1 HD2178.2

• Thermometer with two inputs, the first for Pt100 probes equipped with SICRAM module, the second input for thermocouple type K, J, T, E, N
• large display
• Storage of maximum, minimum, average value
• RS232 C output for data transfer in real time to a PC or printer
• Functions: REL, HOLD and auto power off which can be disabled
• IP 67 protection degree

 

RADIOMETRIC PROBE FOR OUTDOOR MEASURING OF SOLAR IRRADIANCE DELTA OHM LP UVA02

• Radiometric probe for outdoor use for measuring IRRADIANCE in the range UVA (315...400nm).
• mV per mW/cm2 output.
• Complete with Calibration Report.
• On request 5 or 10m cables with connectors

 

HANDHELD DIGITAL THERMOMETER PT100 SENSOR -200°C +650°C DELTA OHM HD2307.0

• Thermometer, Pt100 sensor with one input for probes equipped with SICRAM module,
• measuring range -200°C +650°C
• Storage of maximum, minimum, average value
• Functions: REL, HOLD and auto-power-off which can be disabled
• IP 67 protection degree

 

HVACR DATALOGGER FOR AIR SPEED, FLOW, PRESSURE, TEMPERATURE DELTA OHM DO2003

• HVACR Datalogger to measure: air speed and flow rate with the hot wire probes, vane probes, Pitot tube probes,
• Pt100 temperature probes for immersion, pointed and for surface,
• combined temperature/relative humidity probes.
• Pressure up to 2000 mbar and barometric pressure.
• Max-Min-Med, Rel measurements.
• Storage up to 12,000 readings.
• Serial output RS232C


PORTABLE PH-METER WITH THERMOMETER DELTA OHM HD2305.0

• pHmeter-Thermometer which measures pH, mV and temperature.
• Storage of maximum, minimum, average value.
• Functions: REL, HOLD and auto power off which can be disabled,
• IP 67 protection degree.

 

INTEGRATING SOUND LEVEL METER CLASS I / CLASS II WITH DATALOGGING, SPECTRAL ANALYSIS & STATISTICS DELTA OHM HD2010UC/A

• portable integrating class 1 sound level meter, with data logging function, suitable for performing statistical and spectral analyses
• possibility of adjusting the instrument and adding options at any time
• user can upgrade the firmware directly by means of the Noise Studio programme supplied with the instrument
• Class 1 or 2 sound level meter according to IEC 61672-1 IEC 60651 and IEC 60804
• Class 1 octave and third octave filters according to IEC 61260
• Assessment of the environmental noise level,
• Noise monitoring and optional capture and analysis of sound events,
• Octave and optional third octave band spectrum analysis from 25 Hz to 12.5 kHz,

 

MICRO MANOMETER-THERMOMETER DELTA OHM HD2114P HD2134P

• Micromanometer-Thermometer for air speed and flow rate measurement by means of Pitot tubes
• full scale 20mbar for speed measurements from 2...55m/s.
• Temperature measurement by K type thermocouple.
• Datalogger which stores the maximum, minimum, average value and can store up to 36,000 couples of samples.
• RS232C/ USB output for data transfer in real time to a PC or printer

 

THERMO HYGROMETER DELTA OHM HD2301.0

• Thermo hygrometer, instrument measuring range for temperature -200°C +650°C with probe TP47...
• humidity 0.0...100.0%RH
• Storage of maximum, minimum, average value.
• Functions: REL, HOLD and auto power off which can be disabled
• IP 67 protection degree