Brand: Samar

Standard Capacitor with Fixed Value for Calibrating Samar CC-E50

Code: Samar CC-E50


 

Datasheet PDF, 0.9 Mb

Description

  • Nominal voltage : 500Vdc
  • Temperature coefficient: - (100 ± 50) x 10-6 /°C
  • Test voltage: 2,000Vdc
  • Insulation resistance: 500,000 MW
  • Precision: ± 0.5 % at 1,000 Hz, between terminals
  • ON REQUEST DIFFERENT VALUES FROM THE ONES SHOWN

 

Model

Nominal Value

µF

Tang d

to 1 KHz

CC - E 50/1

1

< 0,0008

CC - E 50/2

0,5

< 0,0008

CC - E 50/3

0,2

< 0,0008

CC - E 50/4

0,1

< 0,0005

CC - E 50/5

0,01

< 0,0005

CC - E 50/6

0,001

< 0,0005

 

 

More products SAMAR

RESISTANCE DECADE BOX SAMAR CR-B

• Power: 0.5 W permanent
• Resistances: 0.1W and 1 W to coil, from 10W to 1 MW metal film to 50ppm
• Security rule terminals
• Plastic box, panel of aluminium with serigraphy
• Double insulation
• Work frequency: 0 - 500 KHz
• Precision: 0.5 %

 

RESISTANCE PRECISION DECADE BOXE SAMAR CR

• DECADES BOXES OF RESISTANCE with switch precision 0.05% at terminals
• Calibration precision: ± 0.02 %
• Thanks to an opportune seasoning process the long term stability is ensured: 10 ppm in the first year and max 20 ppm in three years.
• Switches have a resistance of contact lower than 0.001 W invariable in the time.
• certificate of calibration of our laboratory

 

RESISTOR BOX IN STEPS HIGH VALUES AND HILGH VOLTAGE 5KV SAMAR CRC/4

• Decade box with spires
• studied to simulate high resistance
• suitable to check the insulation testers with test voltage up to 5000V d.c.
• Ranges that can be made with the 4 contact spires supplied: 10x1 M?, 10x10M?, 10x100M?, 10x1G?.
• Temperature coefficient: 100 ppm °C .
• Max power 2W for each element.
• Applicable max voltages : 1250V with 1M?, 2500V with 2M?, 3750V with 3M? and 5000V for values higher than 3M?.

 

INDUCTANCE PRECISION DECADE BOXE SAMAR CI

• certificate of calibration of our laboratory
• DECADES BOXES OF INDUCTANCE with switch
• Copper coils wrapped in air Precision to1.000Hz at terminals ±1%
• ON REQUEST BOXES AT VARIOUS SECTIONS AND TO 1 OR 2 DECADES

 

STANDARD PRECISION CAPACITOR FOR CALIBRATION LABORATORIES SAMAR CC

• Values from 1nF to 1µF
• ON REQUEST DIFFERENT VALUES FROM THE ONES SHOWN
• Nominal voltage: 500Vdc
• Temperature coefficient: - (100 ± 50) x 10-6 /°C
• Test voltage: 2,000Vdc
• Insulation resistance: 500,000 MW
• Precision ± 0.1 % at 1,000 Hz, between terminals

 

RESISTIVE PRECISION DECADE BOXE SAMAR CR-E

• DECADES BOXES OF RESISTANCE with switch precision 0.1% at terminals
• Calibration precision: ± 0.02 %
• The precision shown refers to the terminals and therefore is total resistance included the resistance of zero
• Resistors are in manganine wire (temperature coefficient ± 10 ppm/°C) wrapped in ant-inductive way.
• Thanks to an opportune seasoning process the long term stability is ensured: : 10 ppm in the first year and max. 20 ppm in three years

 

PRECISION REFERENCE VOLTAGE STANDARD SAMAR SC51/SC52

• REFERENCES DC VOLTAGE STANDARD
• certificate of calibration of our laboratory
• DC voltage reference standard providing standard cell accuracy for use in measuring laboratories.
• Nominal e.m.f.: 1.01865 calibration 5°/ 6° decimal digits
• Precision: ± 50 µV / ± 25 µV
• max output current: 1 mA continuative
• stability: < 10 ppm/month with working temperature 15 - 25 °C and relative
• humidity 45-85%

 

HIGH VALUE AND HILGH VOLTAGE STANDARD RESISTORS SAMAR RC80/M

• On request various values and precision
• Nominal Values: 10MO..100TO
• Nominal Voltage 500V
• Included certificate of calibration of our laboratory

 

PRECISION RESISTANCE STANDARD FOR METROLOGY CALIBRATION LABORATORY SAMAR RC80

• On request various values and precision
• Long term stability: +/- 10 ppm per year
• Resistances from 0.0001? to 10? are 4 terminals
• Resistances from 100? to 10M? are two electrolytic copper terminals with 2 screws, one for current and one for voltage
• Included certificate of calibration of our laboratory
• high-accuracy used as standard in laboratory.

 

STANDARD CAPACITOR WITH FIXED VALUE FOR CALIBRATING SAMAR CC-E50

• Values from 1nF to 1µF
• ON REQUEST DIFFERENT VALUES FROM THE ONES SHOWN
• Nominal voltage : 500Vdc
• Temperature coefficient: - (100 ± 50) x 10-6 /°C
• Test voltage: 2,000Vdc
• Insulation resistance: 500,000 MW
• Precision: ± 0.5 % at 1,000 Hz, between terminals