Brand: Samar

Precision Reference Voltage Standard Samar SC51/SC52

Code: Samar SC51/SC52


 

Datasheet PDF, 0.85 Mb

Description

REFERENCES DC VOLTAGE STANDARD

certificate of calibration of our laboratory

DC voltage reference standard providing standard cell accuracy for use in measuring laboratories.

Temperature: 0 to +40 °C operating and storage temperature: - 15 °C to + 60 °C

Power supply: 230V

 

TYPE SC51

Nominal e.m.f.: 1.01865 calibration 5° decimal digits

Precision: ± 50 µV

max output current: 1 mA continuative

stability: < 20 ppm/month with working temperature 15 - 25 °C and relative

humidity 45-85%

 

TYPE SC61

Nominal e.m.f : 1,01865 calibration 6° decimal digits

precision: ± 25 µV

max output current : 1 mA continuative

stability: < 10 ppm//month with working temperature 15 - 25 °C and relative

humidity 45-85%

 

 

 

More products SAMAR

PRECISION RESISTANCE STANDARD FOR USE IN AIR SAMAR RC-E 50

• On request various values and precision
• Long term stability: ± 50 ppm per year
• Resistances from 0.0001? to 0.1? are 4 terminals, two potential and two current.
• Resistances from 1? to 10M? are wrapped in an ant-inductive way and are two terminals with 2 screws for potential and current
• Included certificate of calibration of our laboratory
• high-accuracy used as standard in laboratory.

 

RESISTOR BOX IN STEPS HIGH VALUES AND HILGH VOLTAGE 5KV SAMAR CRC/4

• Decade box with spires
• studied to simulate high resistance
• suitable to check the insulation testers with test voltage up to 5000V d.c.
• Ranges that can be made with the 4 contact spires supplied: 10x1 M?, 10x10M?, 10x100M?, 10x1G?.
• Temperature coefficient: 100 ppm °C .
• Max power 2W for each element.
• Applicable max voltages : 1250V with 1M?, 2500V with 2M?, 3750V with 3M? and 5000V for values higher than 3M?.

 

RESISTANCE DECADE BOX SAMAR CR-B

• Power: 0.5 W permanent
• Resistances: 0.1W and 1 W to coil, from 10W to 1 MW metal film to 50ppm
• Security rule terminals
• Plastic box, panel of aluminium with serigraphy
• Double insulation
• Work frequency: 0 - 500 KHz
• Precision: 0.5 %

 

STANDARD PRECISION CAPACITOR FOR CALIBRATION LABORATORIES SAMAR CC

• Values from 1nF to 1µF
• ON REQUEST DIFFERENT VALUES FROM THE ONES SHOWN
• Nominal voltage: 500Vdc
• Temperature coefficient: - (100 ± 50) x 10-6 /°C
• Test voltage: 2,000Vdc
• Insulation resistance: 500,000 MW
• Precision ± 0.1 % at 1,000 Hz, between terminals

 

STANDARD PRECISION INDUCTOR FOR CALIBRATION LABORATORIES SAMAR IC

• Values from 1mH to 1H
• Inductances of precision used as standard in laboratory
• SAMAR certificate of calibration is supplied with each standard inductor.
• Precision: ± 0.1 % at 1,000 Hz, between terminals
• ON REQUEST DIFFERENT VALUES FROM THE ONES SHOWN

 

STANDARD FIXED VALUE INDUCTANCE FOR CALIBRATION LABORATORIES SAMAR IC-E50

• Values from 1mH to 1H
• Inductances of precision used as standard in laboratory
• SAMAR certificate of calibration is supplied with each standard inductor.
• Precision: ± 0.5 % at 1,000 Hz, between terminals
• ON REQUEST DIFFERENT VALUES FROM THE ONES SHOWN

 

STANDARD CAPACITOR WITH FIXED VALUE FOR CALIBRATING SAMAR CC-E50

• Values from 1nF to 1µF
• ON REQUEST DIFFERENT VALUES FROM THE ONES SHOWN
• Nominal voltage : 500Vdc
• Temperature coefficient: - (100 ± 50) x 10-6 /°C
• Test voltage: 2,000Vdc
• Insulation resistance: 500,000 MW
• Precision: ± 0.5 % at 1,000 Hz, between terminals

 

PRECISION RESISTANCE STANDARD FOR METROLOGY CALIBRATION LABORATORY SAMAR RC80

• On request various values and precision
• Long term stability: +/- 10 ppm per year
• Resistances from 0.0001? to 10? are 4 terminals
• Resistances from 100? to 10M? are two electrolytic copper terminals with 2 screws, one for current and one for voltage
• Included certificate of calibration of our laboratory
• high-accuracy used as standard in laboratory.

 

HIGH VALUE AND HILGH VOLTAGE STANDARD RESISTORS SAMAR RC80/M

• On request various values and precision
• Nominal Values: 10MO..100TO
• Nominal Voltage 500V
• Included certificate of calibration of our laboratory

 

CAPACITANCE PRECISION DECADE BOXE SAMAR CC-B

• certificate of calibration of our laboratory
• DECADES BOXES OF CAPACITY with switch precision 2% at terminals
• Polypropylene capacitor
• Tangd : 0.003 to 1KHz
• Precision: to 1.000Hz at terminals ±2%
• Working voltage: 400Vdc max; 100V switching