Brand: Samar

Precision Reference Voltage Standard Samar SC51/SC52

Code: Samar SC51/SC52


 

Datasheet PDF, 0.85 Mb

Description

REFERENCES DC VOLTAGE STANDARD

certificate of calibration of our laboratory

DC voltage reference standard providing standard cell accuracy for use in measuring laboratories.

Temperature: 0 to +40 °C operating and storage temperature: - 15 °C to + 60 °C

Power supply: 230V

 

TYPE SC51

Nominal e.m.f.: 1.01865 calibration 5° decimal digits

Precision: ± 50 µV

max output current: 1 mA continuative

stability: < 20 ppm/month with working temperature 15 - 25 °C and relative

humidity 45-85%

 

TYPE SC61

Nominal e.m.f : 1,01865 calibration 6° decimal digits

precision: ± 25 µV

max output current : 1 mA continuative

stability: < 10 ppm//month with working temperature 15 - 25 °C and relative

humidity 45-85%

 

 

 

More products SAMAR

CAPACITANCE PRECISION DECADE BOXE SAMAR CC-B

• certificate of calibration of our laboratory
• DECADES BOXES OF CAPACITY with switch precision 2% at terminals
• Polypropylene capacitor
• Tangd : 0.003 to 1KHz
• Precision: to 1.000Hz at terminals ±2%
• Working voltage: 400Vdc max; 100V switching

 

RESISTIVE PRECISION DECADE BOXE SAMAR CR-E

• DECADES BOXES OF RESISTANCE with switch precision 0.1% at terminals
• Calibration precision: ± 0.02 %
• The precision shown refers to the terminals and therefore is total resistance included the resistance of zero
• Resistors are in manganine wire (temperature coefficient ± 10 ppm/°C) wrapped in ant-inductive way.
• Thanks to an opportune seasoning process the long term stability is ensured: : 10 ppm in the first year and max. 20 ppm in three years

 

PRECISION RESISTANCE STANDARD FOR USE IN AIR SAMAR RC-E 50

• On request various values and precision
• Long term stability: ± 50 ppm per year
• Resistances from 0.0001? to 0.1? are 4 terminals, two potential and two current.
• Resistances from 1? to 10M? are wrapped in an ant-inductive way and are two terminals with 2 screws for potential and current
• Included certificate of calibration of our laboratory
• high-accuracy used as standard in laboratory.

 

RESISTANCE PRECISION DECADE BOXE SAMAR CR

• DECADES BOXES OF RESISTANCE with switch precision 0.05% at terminals
• Calibration precision: ± 0.02 %
• Thanks to an opportune seasoning process the long term stability is ensured: 10 ppm in the first year and max 20 ppm in three years.
• Switches have a resistance of contact lower than 0.001 W invariable in the time.
• certificate of calibration of our laboratory

 

STANDARD CAPACITOR WITH FIXED VALUE FOR CALIBRATING SAMAR CC-E50

• Values from 1nF to 1µF
• ON REQUEST DIFFERENT VALUES FROM THE ONES SHOWN
• Nominal voltage : 500Vdc
• Temperature coefficient: - (100 ± 50) x 10-6 /°C
• Test voltage: 2,000Vdc
• Insulation resistance: 500,000 MW
• Precision: ± 0.5 % at 1,000 Hz, between terminals

 

HIGH VALUE AND HILGH VOLTAGE STANDARD RESISTORS SAMAR RC80/M

• On request various values and precision
• Nominal Values: 10MO..100TO
• Nominal Voltage 500V
• Included certificate of calibration of our laboratory

 

PRECISION REFERENCE VOLTAGE STANDARD SAMAR SC51/SC52

• REFERENCES DC VOLTAGE STANDARD
• certificate of calibration of our laboratory
• DC voltage reference standard providing standard cell accuracy for use in measuring laboratories.
• Nominal e.m.f.: 1.01865 calibration 5°/ 6° decimal digits
• Precision: ± 50 µV / ± 25 µV
• max output current: 1 mA continuative
• stability: < 10 ppm/month with working temperature 15 - 25 °C and relative
• humidity 45-85%

 

STANDARD PRECISION CAPACITOR FOR CALIBRATION LABORATORIES SAMAR CC

• Values from 1nF to 1µF
• ON REQUEST DIFFERENT VALUES FROM THE ONES SHOWN
• Nominal voltage: 500Vdc
• Temperature coefficient: - (100 ± 50) x 10-6 /°C
• Test voltage: 2,000Vdc
• Insulation resistance: 500,000 MW
• Precision ± 0.1 % at 1,000 Hz, between terminals

 

INDUCTANCE PRECISION DECADE BOXE SAMAR CI

• certificate of calibration of our laboratory
• DECADES BOXES OF INDUCTANCE with switch
• Copper coils wrapped in air Precision to1.000Hz at terminals ±1%
• ON REQUEST BOXES AT VARIOUS SECTIONS AND TO 1 OR 2 DECADES

 

STANDARD PRECISION INDUCTOR FOR CALIBRATION LABORATORIES SAMAR IC

• Values from 1mH to 1H
• Inductances of precision used as standard in laboratory
• SAMAR certificate of calibration is supplied with each standard inductor.
• Precision: ± 0.1 % at 1,000 Hz, between terminals
• ON REQUEST DIFFERENT VALUES FROM THE ONES SHOWN