Brand: Micronix

Electromagnetic Anechoic Box with Large Window Micronix MY1520SW

Code: Micronix MY1520SW


 

Datasheet PDF, 0.75 Mb
 

Description

  • Large shield window for looking in anechoic shield box
  • Shield characteristic >60 dB @ 2.4 GHz
  • Shading cover for measuring illumination of luminance
  • Several interfaces
 

Model MY1520SW

Outside dimensions

Inside dimensions
Weight approx.
Shielding characteristics
Reflection loss
Shield window dimensions
Connectors
I/F Module installation capacity

Large shield window is equipped normally for looking info an anechoic box

520(W)×520(D)×520(H)mm

460(W)×460(D)×460(H)mm
10kg (without I/F Module)
more than 60dB @ 2.4GHz
more than 20dB @ ? 2.4GHz, MYA-75
300(W)×200(H)mm
2pcs of SMA @ back
2 module @ back

 

Recommended options

Small size (MY1510)
I/F Module
Medium size (MY1520)
I/F Module
Wooden table
Radio wave absorber(MYA-77)
Radio wave absorber(MYA-79)
Large size (MY1530)
I/F Module
Wooden table
Turn table unit
Radio wave absorber(MYA-75)
Radio wave absorber(MYA-79)

 

The I/F module is a module on which AC supply, DC supply, LAN, USB, SMA, BNC, N, Triaxial and/or D-sub connectors are mounted. All of the I/F modules are common to Taurus series.

 

Option

Mounted connectors

IFM1

IFM1 AC(1pc), LAN(1pc), USB(1pc), D-sub9pin(1pc)

IFM2

IFM2 AC(1pc), LAN(2pcs), USB(2pcs), D-sub9pin(1pc)

IFM3

AC(1pc), LAN(2pcs), USB(2pcs), D-sub25pin(1pc)

IFM4

DC(1pc), LAN(1pc), USB(1pc), D-sub9pin(1pc), D-sub25pin(1pc)

IFM5

SMA(2pcs), BNC(2pcs), N(2pcs), Triaxial(2pcs)

 

More products MICRONIX

ELECTROMAGNETIC ANECHOIC SHILEDED BOX FOR EMC TEST MICRONIX MY5305

• Compact size with ferrite absorber
• Optimum for EMC test, receiving sensitivity test and wireless system test for technical regulations

 

ANECHOIC SHIELDING BOX FOR EMI & EMC RADIATIONS MICRONIX ME8669

• These are electromagnetic anechoic box using radio wave absorber of ferrite and ranging 50 to 800MHz
• Outside dimensions : 915 (W) × 650 (H) × 585 (D) mm
• Inside dimensions : 810 (W) × 506 (H) × 506 (D) mm
• Weight : type approx. 165kg
• Capable of customizing

 

ARBITRARY FUNCTION GENERATOR 30V 20 MHZ MICRONIX MFG206

• 1mHz to 20MHz / 30Vp-p (at open load)
• Highly accurate and stable frequency due to synthesized method
• Arbitrary waveform generator (10Mwords / s, 12bits, 128kwords)
• BURST / GATE, frequency sweep (linear and logarithmic) and VCF functions
• Communication (RS-232C, GP-IB [optional] )

 

HANDHELD SPECTRUM ANALYZER 50 KHZ..3.3 GHZ/ 8.5 GHZ MICRONIX MSA300

• 50kHz …3.3 GHz Frequency Range(model MSA438)
• 50kHz …8.5 GHz Frequency Range(model MSA458)
• Compact and lightweight 1.8kg
• Large and color TFT display 5.7 inches, 640x480 dots and color LCD
• 
• Four hours battery operation
• USB memory & communication
• Average noise level -127dBm

 

RF POWER AMPLIFIER 30..1000 MHZ MICRONIX MAP202

• 20 watts power amplifier.
• Frequency range 30 to 1000MHz
• Gain 46dB typ @ 30 to 600MHz

 

SHIELDING BOX WITH CONVEYER FOR MASS PRODUCTION LINES MICRONIX ME8668

• A model equiping with automatic conveyer for mass production line.
• Outside dimensions : 922 (W) × 794 (H) × 731 (D) mm
• Inside dimensions : 801 (W) × 610 (H) × 610 (D) mm
• Weight : approx. 94kg (include automatic conveyer)
• Capable of customizing

 

EMC EMI EMS TESTING SYSTEM MICRONIX MR2300

• The first EMI total test system in the world
• Compact and broadband antenna by our own development
• Small and large anechoic boxes
• Calibration of the entire system
• Conformity to regional and international standards
• Low system price

 

EMS TESTING SYSTEM MICRONIX MR2350

• The electric field strength of 1, 3, 10V/m
• The malfunction of the EUT by the electromagnetic radiation can be observed
• One PC controls all of applications such as the EMI test, the EMS test, the EUT camera monitor and the electric turntable (option)

 

SHIELDED ANECHOIC BOX WITH ABSORBER FOR GSM TEST MICRONIX M8661B

• Equipped with the radio wave absorber covering 800MHz/900MHz frequency band
• Optimum for wireless system test for technical standard, receiving sensitivity test and simple
• EMC test of a wide frequency band

 

ELECTROMAGNETIC ANECHOIC BOX MICRONIX TAURUS-N MY1510N/ MY1520N/ MY1530N

• High quality and reliability the testing and measuring instruments manufacturer offers
• Good cost-performance and short delivery time
• The electromagnetic anechoic box that covers the inside of the shield box with an radio wave absorber