Universal Circuit Breaker Test Sets Megger PS-9130 and PS-9160

Code: Megger PS-9130 and PS-9160


 

Datasheet PDF, 0.1 Mb

Description

Model PS-9130 and Model PS-9160 Series Universal Circuit Breaker Test Sets are specifically designed to test low-voltage power circuit breakers and molded-case circuit breakers that are equipped with thermal magnetic or solid-state trip devices by simulating an overload or fault condition.

 

Model PS-9130 and Model PS-9160 are controlled by the Model PLC-2000 Prime Logic Controls. This microprocessor monitors the output, stores the test data and performs the automatic test functions. After the test information is stored, Model PLC-2000 can print the test data using a built-in RS-232 printer port.

 

Features:

  • Proven power train
  • Rugged instrumentation and controls
  • Direct connection of draw-out type breakers
  • Integral clock/calendar
  • Easy-to-read display
 

More products MEGGER

MEGGER EGIL BREAKER ANALYZER BM-19090 BM-19093 BM-19095

• Suitable for testing timing and travel on all circuit breakers with single interrupter per phase
• Extremely easy-to-use and reliable
• Two separate timing channels for measurement of auxiliary contacts
• Analog measurement channels for travel transducers or general voltage/current measurements
• Static and dynamic resistance measurements along with the SDRM201 accessory

 

MEGGER MTR105 MOTOR TESTER FOR INSULATION LOW RESISTANCE CAPACITY INDUCTANCE ROTATING MACHINE TESTING

• insulation resistance (IR) expertise together with advanced low resistance, capacitance, inductance, and rotation testing in one handheld instrument
• Carry out a complete motor assessment
• Prevent costly failures
• Work in any environment
• Streamline your workflow
• Ensure safe operation


MEGGER TORKEL-840 TORKEL-860 BS-49094 BS-49096 TELECOM BATTERY LOAD DISCHARGE TESTER FOR UPS CELLS

• used for battery systems ranging from 12 to 250 V
• Batteries can be tested "in service"
• Unit adjusts to include load currents in the test parameters
• User adjustable alarm and shutdown points to avoid excessive discharge
• Easily expandable for larger battery banks using TXL extra load units (option)
• Computerized test operation using TorkelWin software (option)

 

MEGGER RCDT300 RCDT310 RCDT320 RCDT330 RCD TESTER FOR RESIDUAL CURRENTS

• Tests standard, DC, selective and programmable RCDs
• Ramp testing (RCDT320/330)
• Auto (Remote) testing (RCDT320/330)
• Three-phase safe

 

MEGGER SMRT33 THREE PHASE RELAY TESTER

• Small, rugged, lightweight and powerful
• Operate with or without a computer
• Intuitive manual operation with Smart Touch View Interface
• High current, high power output - (45 Amps/300 VA rms) per phase
• Network interface provides IEC 61850 test capabilities
• Fully automated testing using AVTS software

 

POCKET SIZED INSULATION AND CONTINUITY TESTERS MEGGER - MIT200 SERIES

• Insulation testing to 1000 MO
• Continuity testing at 200 mA down to 0.01 O
• Live circuit warning (voltage display) and test inhibit
• Digital/Analogue display

 

MEGGER DELTA4310 INSULATION POWER & DISSIPATION FACTOR TEST SET DELTA 4310

• fully automatic 12 kV insulation power factor / dissipation factor (tan delta) test set
• Voltage: 25 V to 12 kV, 1 V resolution
• Current : 0 to 5 Amps, 0.1 µA maximum resolution
• Capacitance: 0 to 100 µF, 0.01 pF maximum resolution
• Inductance: 6 H to 10 MH, 0.1 mH maximum resolution
• Power factor PF : 0-100% (0-1), 0.001% maximum resolution
• Dissipation factor DF : 0-100 (0-10,000%), 0.001% maximum resolution
• Watt Loss: 0 to 2 kW
• Automatic and manual operation
• Accurate and repeatable measurement results with high noise suppression
• Lightweight, rugged two-piece design

 

MEGGER DET2/3 HIGH RESOLUTION ACCURACY EARTH TEST SET

• High resolution of 1 mΩ, ideal for large earth systems
• Versatile tests modes
• High accuracy for earth/ground electrode grid and soil resistivity tests
• Rechargeable battery power that can last all day with a fast re-charge (up to 10 hours)
• Robust instrument with IP65 protection
• Automatic test frequency selection, with filters and high current features
• Diagnostic trace display
• Data storage
• Large colour display that shows numeric and graphical results

 

MEGGER TDR2000/2 TDR CABLE REFLECTOMETER FAULT LOCATOR TDR2000/2RM TDR2000/2R

• 20 km range at VF = 0.90
• Monochrome or colour options
• Primary cell or rechargeable options
• Large back lit LCD Display
• Dual cursor measurement
• Intermittent fault location
• Output pulse amplitude and width control
• Trace Master PC software included
• IP54 Rating
• 2 year Warranty

 

FREQUENCY RESPONSE ANALYZER MEGGER FRAX200 FRAX150 FOR POWER TRANSFORMER

• High dynamic range and accuracy
• Easy-to-use support software with advanced analysis tools
• Smallest SFRA instrument in the industry
• Hardware designed to ensure repeatable connections
• Fulfils international standards for SFRA