Micro-Ohmmeter With Dualground Safety Megger - MJOLNER200

Code: Megger - MJOLNER200


 

Datasheet PDF, 0.9 Mb

Description

The MJ½LNER Series is designed to measure the resistance of circuit breaker contacts, bus-bar joints, contact elements in bus-bars and other high-current links. This product has been designed with safety, ease of use and versatility in mind. It can be used anywhere to measure a low resistance value with high accuracy. It conducts true DC ripple free current testing of bus bars, circuit breakers, fuses, etc.

 

Features:

  • Specifically designed for measuring contact resistances in circuit breakers, disconnecting switches, bus-bar joints, and other such devices
  • Safer testing using the patented DualGroundâ„¢ technology to test circuit breakers with both sides grounded
  • Fully automatic testing- microprocessor controlled
  • Wide measuring range and test currents
  • High powered and light
 

More products MEGGER

MEGGER MPAC208 ACOUSTIC CAMERA FOR GAS LEAKS, MECHANICAL FAULTS AND PARTIAL DISCHARGES

• Pinpoint issues fast
• Quantify leak and energy loss
• Reliable PD insight
• Works in noisy environments
• Optional thermal overlay
• Available in comprehensive kit

 

COMBINED LOOP AND RCD TESTERS MEGGER - LRCD210 AND LRCD220

• Non-trip loop tester
• RCD testing from 10 mA to 1000 mA
• Extremely easy and safe to use
• Built-in protective front cover

 

MEGGER TORKEL-840 TORKEL-860 BS-49094 BS-49096 TELECOM BATTERY LOAD DISCHARGE TESTER FOR UPS CELLS

• used for battery systems ranging from 12 to 250 V
• Batteries can be tested "in service"
• Unit adjusts to include load currents in the test parameters
• User adjustable alarm and shutdown points to avoid excessive discharge
• Easily expandable for larger battery banks using TXL extra load units (option)
• Computerized test operation using TorkelWin software (option)

 

MEGGER IMT100 MULTIFUNCTION INDUSTRIAL TESTER FOR PHOTOVOLTAIC INSTALLATIONS

• Powerful 3-in-1 tester for safe, accurate PV installation
• Exceptionally safe to use
• Complete suite of insulation resistance
• Ready for outdoor conditions

 

MEGGER OTS60PB OTS80PB OIL BREAKDOWN TESTER 60KV 80KV

• portable 60 kV and 80 kV oil test sets
• Lightest - miniumum weight 16 kg
• Lock in precision - oil vessel with lockable adjustment
• Bright 3.5 inch colour display visable out doors
• Suitable for mineral, ester and silicon oils
• Trip detection circuit with direct measure ment of voltage and current
• Ultra fast (<10 µs) HV switch off time

 

MEGGER OTS60AF OTS80AF OTS100AF OIL BREAKDOWN TESTER 60KV 80KV 100KV

• Test voltages : 60 kV, 80 kV and 100 kV
• Laboratory instruments for measuring insulating oil breakdown voltage
• Lock in precision - oil vessel with lockable adjustment
• Bright 3.5" colour display
• Suitable for mineral, ester and silicon oils
• Trip detection circuit with direct measurement of voltage and current
• Ultra fast (< 10 µs) HV switch off time

 

MEGGER SMRT1 SINGLE PHASE RELAY TESTER

• Small, rugged, lightweight and powerful
• Operate with or without a computer
• Intuitive manual operation with Smart Touch View Interface
• High current, high power (75 Amps/400 VA rms)
• Network interface provides IEC 61850 test capabilities
• Fully automated testing using AVTS software

 

MEGGER TDR2000/2 TDR CABLE REFLECTOMETER FAULT LOCATOR TDR2000/2RM TDR2000/2R

• 20 km range at VF = 0.90
• Monochrome or colour options
• Primary cell or rechargeable options
• Large back lit LCD Display
• Dual cursor measurement
• Intermittent fault location
• Output pulse amplitude and width control
• Trace Master PC software included
• IP54 Rating
• 2 year Warranty

 

MEGGER DELTA4310 INSULATION POWER & DISSIPATION FACTOR TEST SET DELTA 4310

• fully automatic 12 kV insulation power factor / dissipation factor (tan delta) test set
• Voltage: 25 V to 12 kV, 1 V resolution
• Current : 0 to 5 Amps, 0.1 µA maximum resolution
• Capacitance: 0 to 100 µF, 0.01 pF maximum resolution
• Inductance: 6 H to 10 MH, 0.1 mH maximum resolution
• Power factor PF : 0-100% (0-1), 0.001% maximum resolution
• Dissipation factor DF : 0-100 (0-10,000%), 0.001% maximum resolution
• Watt Loss: 0 to 2 kW
• Automatic and manual operation
• Accurate and repeatable measurement results with high noise suppression
• Lightweight, rugged two-piece design

 

CURRENT SUPPLY UNIT MEGGER ½ CSU600A AND CSU600AT

• Compact and rugged
• Quick and easy to us
• Broad application range
• Excellent weight/performance ratio