Megger TDR1000/3 Time domain reflectometer & cable fault locator

Code: Megger TDR1000/3


 

Datasheet PDF, 0.14 Mb

Description

• Simple operation.
• AUTO set up for instant use.
• Ultra fast pulse for near end fault identification.
• Trace HOLD feature to allow comparison between cables.
• IP54 rating offers real life working.
• Designed for use on all metallic cable pairs.

 

The TDR1000/3 is a hand held, compact Time Domain Reflectometer for locating faults on metallic cables. It has a minimum resolution of 0.1 m and a 5 km maximum range depending on velocity factor selected and cable type.

Four output impedances are available (25, 50, 75, and 100 O) and a velocity factor between 0.2 and 0.99 will meet any cable test requirements.

 

Standard accessories

Time Domain Reflectometer TDR1000/3

 

Included accessories

Hard carry case 5410-420

Miniature clip test lead set 6231-652

User guide CD 2002-178

 

Optional accessories

Fused test lead set 1002-015

 

More products MEGGER

MEGGER IMT100 MULTIFUNCTION INDUSTRIAL TESTER FOR PHOTOVOLTAIC INSTALLATIONS

• Powerful 3-in-1 tester for safe, accurate PV installation
• Exceptionally safe to use
• Complete suite of insulation resistance
• Ready for outdoor conditions

 

INSTRUMENT TEST BOX MEGGER - MTB7671/2

• The only one that fully tests your instruments to the regs.
• Tests the full range of your tester½s capability not just what½s easy
• Won½t trip RCD protected circuits
• Checks insulation, continuity, loop and RCD functions of testers
• Works with all testers for Part P Certification

 

MULTI-AMP CIRCUIT BREAKER TESTER RETROFIT MEGGER DDA16, DDA30 AND DDA60

• Drop-in retrofit capability to the Multi-Amp Model CB-9116, Model DB-8130 and Model CB-8160 circuit breaker test sets
• Digital Signal Processing (DSP) technology
• Variable pulse time and firing-angle output-current control
• Complies with NEMA AB-4 Test Guidelines

 

MEGGER SMRT410 RELAY TEST SYSTEM

• Small, rugged, lightweight and powerful
• Operates with or without a computer
• Intuitive manual operation with Smart Touch View Interface
• High current, high power output (60 Amps/300 VA rms) per phase
• Flexible output design provides up to 4-phase voltage and up to 10-phase current
• Network interface provides IEC 61850 test capabilities
• Fully automated testing using AVTS software

 

MEGGER EGIL BREAKER ANALYZER BM-19090 BM-19093 BM-19095

• Suitable for testing timing and travel on all circuit breakers with single interrupter per phase
• Extremely easy-to-use and reliable
• Two separate timing channels for measurement of auxiliary contacts
• Analog measurement channels for travel transducers or general voltage/current measurements
• Static and dynamic resistance measurements along with the SDRM201 accessory

 

MEGGER S1-1068/2 EXPERT 10KV INSULATION RESISTANCE MEGOHMMETER

• Reliable results in noisy substations
• Accurate testing with RE>Actâ„¢
• Remote control for safer, easier testing
• PI Predictorâ„¢ cuts test time in half
• Full diagnostic suite with PDC capability

 

MEGGER OTS60PB OTS80PB OIL BREAKDOWN TESTER 60KV 80KV

• portable 60 kV and 80 kV oil test sets
• Lightest - miniumum weight 16 kg
• Lock in precision - oil vessel with lockable adjustment
• Bright 3.5 inch colour display visable out doors
• Suitable for mineral, ester and silicon oils
• Trip detection circuit with direct measure ment of voltage and current
• Ultra fast (<10 µs) HV switch off time

 

IRRADIANCE METER MEGGER - PVM210

• Optimal incident angle and positioning of solar panels
• Measurement of solar power for panel short circuit calculation
• 33/4 digit LCD display with 1999 W/m2 range
• Single handed use

 

EARTH LEAKAGE CLAMPMETER MEGGER - DCM300E

• 0.01 mA resolution
• EMC and IEC61010-2-032 compliance
• 30 mA, 300 mA, 30 A and 300 A range

 

MEGGER DLRO10X RESISTANCE OHMMETER DLRO 10 DLRO 10X 6111-428 6111-429

• up to 10A current
• Accurate results in under three seconds
• Auto current reversal cancels standing emfs
• Fuse protected to 600 V
• NiMH battery reduces weight
• 250 mW power limit (with optional override) to avoid heating the test sample