MEGGER DET2/3 High Resolution Accuracy Earth Test Set

Code: DET2/3 DET23 DET2-3 1008-964 1008-984 1008-944 ETKETK30 ETK50 ETK100


 

Datasheet PDF, 0.85 Mb
Datasheet PDF, 0.94 Mb
                 

Description

About the product
  • High resolution of 1 mΩ, ideal for large earth systems
  • Versatile tests modes
  • High accuracy for earth/ground electrode grid and soil resistivity tests
  • Rechargeable battery power that can last all day with a fast re-charge (up to 10 hours)
  • Robust instrument with IP65 protection
  • Automatic test frequency selection, with filters and high current features
  • Diagnostic trace display
  • Data storage
  • Large colour display that shows numeric and graphical results
  • Optional earth testing kit (ETK) available


The DET2/3 high resolution earth tester is a robust and compact automatic earth) test instrument designed to measure earth electrode resistance and soil resistivity. For use on large or more complex earth systems, which include communications earth systems and difficult test environments, it can be used to test in accordance with BS 7430 (earthing/grounding), BS-EN-62305 (lightning protection), BS-EN-50122-1 (railway applications), and IEEE Standard 81.

Test frequency, test current, and filtering can be quickly and easily adjusted so that adverse conditions, which can influence the test, can be overcome, and a wide band of test current frequencies, with a resolution of 0.5 Hz, can be used to eliminate errors caused by noise in the earth.

With its microprocessor controlled system it provides a flexible and ‘user-friendly’ approach to earth/ground tests by the provision of excellent error detection capabilities and full test information shown on a large colour display. The DET2/3 can provide a live trace of its measurements, which graphically shows the amount of noise from the system under test - a powerful diagnostic tool for the expert earth/ground test engineer.

The DET2/3 also includes an automatic frequency selection feature that scans for frequencies with the lowest noise level and then runs a test at that frequency. The selected test current frequency, test current level, and the increased filtering option are stored in memory for use in subsequent tests.

Use of the latest processors and a large internal memory allows for immediate calculations of resistivity (Wenner or Schlumberger method) and the ability to save a complete days’ worth of test results. Test result data can be downloaded directly through a USB drive or straight to a Windows PC running PowerDB™ software.

Video MEGGER DET2/3








 

Standard accessories

DET2/3 Earth Tester with ETK 50M (UK plug) 1008-963
DET2/3 Earth Tester with ETK 50M (SCHUKO plug) 1008-964
DET2/3 Earth Tester with ETK 50M (US plug) 1008-969
DET2/3 Earth Tester with ETK 100M (UK plug) 1008-983
DET2/3 Earth Tester with ETK 100M (SCHUKO plug) 1008-984
DET2/3 Earth Tester with ETK 100M (US plug) 1008-989
DET2/3 Earth Tester (UK plug) 1008-942
DET2/3 Earth Tester (SCHUKO plug) 1008-944
DET2/3 Earth Tester (US plug) 1008-949
 

Recommended options

Optional accessories
Cable reel kit ETK30 1010-176
Cable reel kit ETK50 1010-177
Cable reel kit ETK100 1010-178
Cable reel kit ETK50C 1010-179
Cable reel kit ETK100C 1010-180
Clamp MCC1010 1010-516
Clamp MVC1010 1010-518
Terminal adapter, detachable retro-fit for
C1, P1, P2, C2 connectors 1012-511
Power supply 18V73-5A 1010-793
UK mains plug 1010-789
US mains plug 1010-791
SCHUKO mains plug 1010-792
AUS/NZ mains plug 1010-790
 

More products MEGGER

MEGGER DELTA4110 INSULATION POWER & DISSIPATION FACTOR TEST SET DELTA4000

• fully automatic 12 kV insulation power factor / dissipation factor (tan delta) test set
• Voltage: 25 V to 12 kV, 1 V resolution
• Current : 0 to 5 Amps, 0.1 µA maximum resolution
• Capacitance: 0 to 100 µF, 0.01 pF maximum resolution
• Inductance: 6 H to 10 MH, 0.1 mH maximum resolution
• Power factor PF : 0-100% (0-1), 0.001% maximum resolution
• Dissipation factor DF : 0-100 (0-10,000%), 0.001% maximum resolution
• Watt Loss: 0 to 2 kW
• Automatic and manual operation
• Accurate and repeatable measurement results with high noise suppression
• Lightweight, rugged two-piece design

 

MEGGER DLRO10X RESISTANCE OHMMETER DLRO 10 DLRO 10X 6111-428 6111-429

• up to 10A current
• Accurate results in under three seconds
• Auto current reversal cancels standing emfs
• Fuse protected to 600 V
• NiMH battery reduces weight
• 250 mW power limit (with optional override) to avoid heating the test sample

 

MEGGER TTRU1 TRANSFORMER TURN RATIO TESTER

• Battery operated with USB-C rechargeablenAA NiMH batteries included
• Pass/Fail ratio evaluation
• Automatic results storage
• USB drive save and export
• Full colour Hi-bright LCD screen
• Additive / Subtractive polarity detection
• Excitation current

 

PRIMARY CURRENT INJECTION TEST SYSTEM MEGGER ODEN AT

• Most advanced primary current injection test system to simplify all types of switchgear and CT commissioning, ground grid, circuit breaker testing and more
• Modular design to permit optimal user configuration of output current vs. unit size
• Compact transport cart facilitates portability into switchgear rooms with limited space
• Unique I/30 function allows the current to be pre-set using low current to prevent test sample heating, thus eliminating corruption of test result

 

MEGGER SMRT410 RELAY TEST SYSTEM

• Small, rugged, lightweight and powerful
• Operates with or without a computer
• Intuitive manual operation with Smart Touch View Interface
• High current, high power output (60 Amps/300 VA rms) per phase
• Flexible output design provides up to 4-phase voltage and up to 10-phase current
• Network interface provides IEC 61850 test capabilities
• Fully automated testing using AVTS software

 

MEGGER - B10E

• Reliable and stable a.c. and d.c. power supply for circuit breaker testing
• Continuously variable 24-250 V AC or DC output
• Separate outputs for close coil, trip coil and spring charging motor voltage
• Direct triggering for minimum trip voltage testing

 

MEGGER GOOSER IEC 61850 RELAY TESTER

• Reliable testing of IEC61850 relays using a conventional relay test set
• Separate Ethernet ports for the substation LAN and the controlling PC forming a Safe Substation Bus Access Point
• Seamless interaction between SCL GOOSE and GOOSE "sniffing"
• GOOSE merge - SCL GOOSE vs captured GOOSE for network troubleshooting and SCD file validation at FAT
• Stand alone functionality - Download a configuration and run

 

MEGGER MIT1025/2 10KV INSULATING RESISTANCE MEGOMETER

• Diagnostic testing with full test suite
• PI Predictor™ cuts test time in half
• Accurate testing with RE>Act™
• Built-in storage and easy data export
• Designed for safe testing in the field

 

DIGITAL MULTIMETER MEGGER - DCM340

• DC and AC current and voltage
• 600 A and 600 V
• Resistance and continuity
• 31/2 digit, 4000 count display with backlight
• High resolution digital bargraph

 

MEGGER SVERKER900 THREE PHASE RELAY TESTER

• The toolbox for substation 3-phase testing
• Three currents and four voltages
• Stand-alone functionality
• Rugged and reliable for field use
• Generation of 900 V and 105 A in single phase mode
• Secondary and primary testing