MEGGER MIT515/2 5kV Insulation Resistance Megohmmeter

Code: MIT515/2 MIT515-2 MIT515/2-EU 1016-080


 

Datasheet PDF, 0.92 Mb
     

Description

  • RE>Act mode enhanced accuracy and safety
  • PI predictor function (PIp)
  • Measures up to 20 TΩ
  • Up to 3 mA noise rejection
  • Safety rated up to CAT IV 1000 V to 3000 m
  • Unique dual-case design – additional user protection
  • Operates from battery or AC mains supply
  • Rapid charge Li-ion battery

DESCRIPTION
The Megger range of 5, 10 and 15 kV insulation testers
are known worldwide for their rugged dependability,
long service life and accurate, reliable measurements.
The extensive range of models means that there will
always be a perfect match for your requirements. One
common feature across the whole range is the Megger,
‘no compromise’ approach to safety. The Megger level
of safety will always go further than simply complying
with the relevant safety standards.
Another common feature is the intuitive colour custom
display, with its ability to work in extreme environments
and unbeatable viewing angle.
The range starts with the MIT (Megger Insulation Tester)
models. These instruments provide an excellent level of
noise immunity, test performance, and safety.
For customers requiring higher capacitance charge
rates (testing long cables), working in electrically noisy
environments (e.g. transmission voltages), remote
operation, or data storage, the S1 models are the ideal
solution.
Once the best level has been selected, the only remaining
choice is the maximum test voltage required.
The Essential models come in either 5 kV or 10 kV,
whilst Advanced and Expert come in either 5, 10 or
15 kV instruments.
Please see the selection chart on page 2 of this data
sheet for more detailed information on the differentiating
features across the range.
 

Standard accessories

Description Part number
MIT515/2-UK ESSENTIAL 5kV IRT PIP 1016-079
MIT515/2-EU ESSENTIAL 5kV IRT PIP 1016-080
MIT515/2-US ESSENTIAL 5kV IRT PIP 1016-081
MIT515/2-AU ESSENTIAL 5kV IRT PIP 1016-082
MIT515/2-CN ESSENTIAL 5kV IRT PIP 1016-083
MIT515/2-BR ESSENTIAL 5kV IRT PIP 1016-621
MIT1015-UK ESSENTIAL 10kV IRT PIP 1016-089
MIT1015-EU ESSENTIAL 10kV IRT PIP 1016-090
MIT1015-US ESSENTIAL 10kV IRT PIP 1016-091
MIT1015-AU ESSENTIAL 10kV IRT PIP 1016-092
MIT1015-CN ESSENTIAL 10kV IRT PIP 1016-093
MIT1015-BR ESSENTIAL 10kV IRT PIP 1016-623

cluded accessories
Power lead 1008-017
Calibration certificate
Lead sets
Lead set 3kV 3 x 3 m, with medium clips 1008-022
Lead set HV 3 x 3 m, with medium and large clips
(MIT1015 only) 1002-534
1 kV test lead sets
Fused test probe and clip lead set 1002-913
Control circuit test set 6220-822


 

Recommended options

OPTIONAL HV TEST LEAD SETS

HV test leads sets (MIT515/2, MIT1015 only)
These test leads may also be supplied in non-standard lengths to suit
a particular application / requirement. Contact Megger
for a quotation, minimum order quantities may apply.
3 x 3 m with large clips (MIT1015 only) 1002-534
3 x 5 m with large insulated clips 1002-645
3 x 8 m with large insulated clips 1002-646
3 x 10 m with large insulated clips 1002-647
3 x 15 m with large insulated clips 1002-648
3 x 3 m with medium clips 1008-002
3 x 5 m with medium insulated clips 1002-641
3 x 8 m with medium insulated clips 1002-642
3 x 10 m with medium insulated clips 1002-643
3 x 15 m with medium insulated clips 1002-644

Screened HV test lead sets (MIT515/2, MIT1015 only)
1 x 15 m, with 5 kV screened uninsulated small clips 6311-080
3 m, 10 kV screened uninsulated small clips 6220-834
10 m, 10 kV screened uninsulated small clips 6220-861
15 m, 10 kV screened uninsulated small clips 6220-833
Other
CB101 5 kV Calibration Box 6311-077
UKAS calibration certificate 1000-047
 

More products MEGGER

MEGGER MIT400/2 MIT410/2 MIT420/2 MIT430/2 CAT IV INSULATION TESTER WITH 1000V

• nsulation testing up to 1000 V and 200 GΩ range
• Stabilised insulation test voltage (New)
• Single range, faster continuity testing from 0.01 Ω to 1 MΩ (New)
• 600 V T RMS AC and DC voltage measurement

 

MEGGER EGIL BREAKER ANALYZER BM-19090 BM-19093 BM-19095

• Suitable for testing timing and travel on all circuit breakers with single interrupter per phase
• Extremely easy-to-use and reliable
• Two separate timing channels for measurement of auxiliary contacts
• Analog measurement channels for travel transducers or general voltage/current measurements
• Static and dynamic resistance measurements along with the SDRM201 accessory

 

MEGGER FREJA 300 PROGRAMMA RELAY TESTER CF-19091

• can generate 4x150 V (82 VA) and 3x15 A (87 VA) or 1x45 A (250 VA).
• Manual and automatic control
• Easy to use
• Excellent software provides great visuals and simple setup
• Lightweight and portable
• Highly accurate
• User can calibrate unit

 

MEGGER DET14C 1000-761 DET24C 1000-762 EARTH RESISTANCE CLAMP METER

• Elliptical clamp shape improves access to earth cables and straps up to 50 mm
• Low maintenance flat jaw interface
• Measures ground resistance from 0.05 O to 1500 O
• Measures true RMS ground leakage current from 0.5 mA rms to 35 A rms
• CAT IV 600 V safety rating
• Backlit LCD display

 

MEGGER TORKEL 820 BS-49092 TELECOM BATTERY LOAD DISCHARGE TESTER PROGRAMMA

• Combines efficiency with portability
• Batteries can be tested "in service"
• Discharge 24 and 48 V batteries at a current of 270 A
• 12 V batteries at 135 A
• Two or more TORKEL 820 units and/or extra load units TXL, can be linked together if you need higher current.

 

MEGGER OTS60PB OTS80PB OIL BREAKDOWN TESTER 60KV 80KV

• portable 60 kV and 80 kV oil test sets
• Lightest - miniumum weight 16 kg
• Lock in precision - oil vessel with lockable adjustment
• Bright 3.5 inch colour display visable out doors
• Suitable for mineral, ester and silicon oils
• Trip detection circuit with direct measure ment of voltage and current
• Ultra fast (<10 µs) HV switch off time

 

BATTERY GROUND FAULT LOCATOR MEGGER - BGL

• Ground faults in ungrounded dc battery systems easily located
• Operates in high electrical noise environment
• Simplifies fault tracing by identifying fault characteristic (resistive and capacitive) magnitudes

 

MEGGER FREJA 306 PROGRAMMA RELAY TESTER CF-29091

• current outputs, higher amps (3 x 15 A + 3 x 35 A), VA or compliance voltage.
• test differential relays with 6 currents, or virtually any single or 3-phase relay
• For secondary testing of protection relays
• Can be used stand-alone or with a PC
• Flexble, can test many relay types
• Lightweight and portable
• Greatest possible precision

 

MEGGER DLRO200 DUCTOR MICRO-OHMMETER 200A 6220-755

• Small and weighs less than 15kg
• Test currents from 10 A to 200 A d.c.
• 0.1 µO best resolution
• On board memory for up to 300 test results and notes
• RS232 port to download stored results or for real time output to a printer
• Supplied complete with 5m test leads and download software

 

MEGGER TM1800 CIRCUIT BREAKER ANALYZER CG-19290 CG-19292 CG-19294 CG-19296

• Modular based design - user configurable TM1800 from nine different modules
• Built in PC with CABA Local software - advanced testing with predefined breaker test plans (templates), onsite measurement view and analysis
• Dual ground testing using DCM module - increased safety with both sides of breaker grounded
• Fast and easy testing - Select-Connect-Inspect workflow and high level user interface
• Graphical results for quick interpretation - timing and motion measurements, coil currents
• USB and Ethernet communication interface - for quick back up, LAN connection and printer options
• CABA Win - for advanced data analysis, database interface and common test data archive