• fully automatic 12 kV insulation power factor / dissipation factor (tan delta) test set • Voltage: 25 V to 12 kV, 1 V resolution • Current : 0 to 5 Amps, 0.1 µA maximum resolution • Capacitance: 0 to 100 µF, 0.01 pF maximum resolution • Inductance: 6 H to 10 MH, 0.1 mH maximum resolution • Power factor PF : 0-100% (0-1), 0.001% maximum resolution • Dissipation factor DF : 0-100 (0-10,000%), 0.001% maximum resolution • Watt Loss: 0 to 2 kW • Automatic and manual operation • Accurate and repeatable measurement results with high noise suppression • Lightweight, rugged two-piece design
• Direct 2-channel digital reading (1 µO to 2000 O) • DC test current up to 10 A maximum • 0.25% measurement accuracy • Integrated demagnetization feature • Tests operation of on-load tap-changers • Very fast auto safety discharge circuit
• Interchangeable test lead terminations
• High or low output power selection for condition diagnosis
• Operates from battery or AC mains supply
• Protected to 600 V without blowing a fuse, test lead live voltage warning light
• Determines health of lead-acid cells up to 2000 Ah • On-line testing with Pass/Warning/Fail calculations • Measures impedance, interconnection resistance and cell voltage • Windows CE operating system with 32 MB of memory • Measures float and ripple currents • Includes PowerDB LITE Management Software
• current outputs, higher amps (3 x 15 A + 3 x 35 A), VA or compliance voltage. • test differential relays with 6 currents, or virtually any single or 3-phase relay • For secondary testing of protection relays • Can be used stand-alone or with a PC • Flexble, can test many relay types • Lightweight and portable • Greatest possible precision
• DC and AC current and voltage
• 600 A and 600 V
• Resistance and continuity
• 31/2 digit, 4000 count display with backlight
• High resolution digital bargraph
• best resolution of 0.1m the TDR2000/2 has a 20km maximum range • Comprehensive Dual Channel capability with dual aspect display. • AUTO set up mode for instant use. • Ultra fast pulse for near end fault identification. • Xpert guidance to potential fault. • IP54 rating offers real life working. • Designed for use on all metallic paired cables.
• The only one that fully tests your instruments to the regs.
• Tests the full range of your tester½s capability not just what½s easy
• Won½t trip RCD protected circuits
• Checks insulation, continuity, loop and RCD functions of testers
• Works with all testers for Part P Certification
• Small, rugged, lightweight and powerful • Operates with or without a computer • Intuitive manual operation with Smart Touch View Interface • High current, high power output (60 Amps/300 VA rms) per phase • Flexible output design provides up to 4-phase voltage and up to 10-phase current • Network interface provides IEC 61850 test capabilities • Fully automated testing using AVTS software