Pressure Calibrator Fluke 717

Code: Fluke 717


 

Datasheet PDF, 0.54 Mb

Description

  • Measure pressure, 0.05% of full scale with internal sensor up to 5000 PSI/345 bar sensor (5000G model)
  • Measure mA with 0.015% accuracy and 0.001 mA resolution, while sourcing 24V loop power
  • Measure pressure to 10,000 psi/700 bar using one of 29 Fluke 700Pxx Pressure Modules
  • 1/8 NPT female pressure fitting
  • Compatible with non-corrosive Gases and liquids
  • Select eleven different engineering units
  • Zero, min, max, and hold functions
  • Calibrate P/I instruments with simultaneous pressure and current measurement
  • Pressure switch test function captures set, reset and Deadband values of a pressure switch
  • Error% calculation of mA measurements for quick pass-fail decisions
  • Long lasting battery life
  • Holster features test lead storage
  • Compatible with Toolpack magnetic hanging system
  • New switch test
 

Standard accessories

  • Protective Yellow Holster with test lead storage
  • Instructions Sheet (14 languages)
  • single 9V alkaline battery
  • Test Leads and Alligator Clips
  • NIST- traceable calibration report and data
 

Recommended options

Fluke 717 1G

Pressure Calibrator -1 to 1 PSI, (-689 mbar to 689 mbar, -689 to 689 kPa)

Fluke 717 30G

Pressure Calibrator -12 to 30 psi (-850 mbar to 2 bar, -85 to 207 kPa)

Fluke 717 100G

Pressure Calibrator -12 to 100 PSI, (-850 mbar to 7 bar, -85 to 68948 kPa)

Fluke 717 300G

Pressure Calibrator -12 to 300 PSI, (-850 mbar to 20 bar, -85 to 20684 kPa )

Fluke 717 500G

Pressure Calibrator 0 to 500 PSI, (0 mbar to 347 bar, 0 to 34474 kPa )

Fluke 717 1000G

Pressure Calibrator 0 to 1000 PSI, (0 mbar to 69 bar, 0 to 68948 kPa )

Fluke 717 1500G

Pressure Calibrator 0 to 1500 PSI, (0 bar to 1034 bar, 0 to 10342 kPa )

Fluke 717 3000G

Pressure Calibrator 0 to 3000 PSI, (0 bar to 207 bar, 0 to 20684 kPa)

Fluke 717 5000G

Pressure Calibrator 0 to 5000 PSI, (0 bar to 345 bar, 0 to 34474 kPa)

 

More products FLUKE

FLUKE 437 II POWER QUALITY AND ENERGY ANALYZER

• 400 Hz measurement
• Power inverter efficiency: Simultaneously measure AC output power and DC input power
• PowerWave data capture: Capture fast RMS data, show half-cycle and waveforms
• Energy loss calculator
• Troubleshoot real-time
• Highest safety rating in the industry
• Measure all three phases and neutral

 

FLUKE 1577 MEGOHMMETER INSULATION MULTIMETER 500/ 1000V

• Insulation test: 0.1 MO to 600 MO
• Insulation test voltages: 500 V, 1000 V

 

LOOP CURRENT PRECISION CALIBRATOR FLUKE 709

• Functions: mA source, mA simulate, mA read, mA read/loop power and volts read
• Best-in-class accuracy at 0.01% reading
• Small rugged design operates on (6) standard AAA batteries
• Intuitive user interface with Quick-Set knob for fast setup, easy use
• Built in selectable 250 ? resistor for HART communication

 

FLUKE MEMOBOX 1744 THREE PHASE POWER QUALITY LOGGER

• monitor & logging: V, A, W, VA, VAR, PF, energy, flicker, voltage events, and THD
• measures voltage & current harmonics, interharmonics, mains signaling, unbalance, frequency
• Plug and play
• Determines the root cause
• Monitors power for the long-term
• 0.1% voltage accuracy IEC61000-4-30 Class-A compliant
• IP65 water-proof

 

TRUE-RMS CURRENT CLAMP METER 400 A FLUKE 324

• 400 A ac current measurement
• 600 V ac and dc voltage measurement
• True-rms ac voltage and current for accurate measurements on non-linear signals
• Resistance measurement up to 40 k? with continuity detection
• Temperature and capacitance measurement

 

FLUKE 6304/ 6304C AUTOMATIC RCL METER 50 HZ..100 KHZ

• 50, 60, 100, 120 Hz, 200 Hz to 20 kHz (100 Hz steps), 100 kHz test frequencies
• 0.1 % basic accuracy (0.05 % for PM 6304C)
• Easy to use, at-a-glance display

 

FLUKE 6306 AUTOMATIC RCL METER 50 HZ..1 MHZ

• 50, 60, 100, 120 Hz 200 Hz to 100 kHz (100 Hz steps)
• 100 kHz to 1 MHz (1 kHz steps) test frequencies
• 0.1 % basic accuracy
• Easy to use, at-a-glance display

 

FLUKE VT04A INFRARED THERMOMETER WITH INTEGRATED CAMERA

• take simultaneous visual images with the thermal heat map images that are accurately aligned close in
• Temperature measurement range -10 °C to +250 °C (14 °F to 482 °F)
• Infrared spectral band 6.5 µm to 14 µm
• Minimum focus distance 50 cm (19.6 in)
• Field of View 28° X 28°
• 4 GB Micro SD card

 

FLUKE 1750 THREE PHASE POWER LOGGER

• Power quality that meets the standard: comply with IEC61000-4-30 standards for voltage, current, power, harmonics, flicker etc.
• 5 MHz, 8000 Vpk waveform capture: Get a detailed picture of even the shortest events
• 5 MHz Transient Voltage
• Captures everything
• Plug and play
• Wireless connection

 

FLUKE 190-504 190-504/S HANDHELD SCOPEMETER OSCILLOSCOPE 4X500 MHZ

• 4-channels isolated 500MHz
• CAT III 1000V / CAT IV 600V safety rated
• Dedicated 5000 Count digital multimeter in two-channel models
• Advanced automatic measurements, power (Vpwm, VA, W, PF) and time (mAs, V/s, w/s)
• IP-51 rated for dust and drip proof to withstand harsh environments
• Isolated USB ports for memory devices and PC connectivity